98 Results
Export of analog and digital channels of the same acquistion
We want to measure the voltage of the main line with our oscilloscope.
When I do RMS measurements and an offset is applied, the result changes. I could not see that effect on other scopes. What is wrong here?
The Rohde & Schwarz option K65, SpaceWire trigger & decode, for R&S®RTE and R&S®RTO offers triggering and decoding of SpaceWire protocol communication. Video, RTO2000, Oscilloscope, SpaceWire Triggering & Decoding The Rohde & Schwarz option K65, SpaceWire trigger & decode, for R&S®RTE and R&S®RTO offers triggering and decoding of SpaceWire protocol communication.
Oscilloscopes for debugging automotive Ethernet networks - Application Brochure
The R&S®RTE and R&S®RTO oscilloscopes can measure currents down to 100 uA using their low noise and high-sensitivity current probe. Video, RTO2000, Oscilloscope, Measurement of very small currents The R&S®RTE and R&S®RTO oscilloscopes can measure currents down to 100 uA using their low noise and high-sensitivity current probe.
I have compared passive and active probes. It seems that the noise with active probes is higher. What is the reason and what can I do to reduce the noise?
I have exported the waveform into a csv file. When I open the file in Excel, the values are completely wrong. How can I get correct values?
EMI Debugging with the R&S RTO and R&S RTE Oscilloscopes
25-Jun-2014 | AN-No. 1TD05
29-Apr-2015
Frost & Sullivan Lauds Rohde & Schwarz for Standing out in the Oscilloscopes Market through Innovations and Value Additions to its Product PortfolioBased on its recent analysis of the oscilloscopes market, Frost & Sullivan recognises Rohde & Schwarz with the 2015 Global Frost & Sullivan Award for Competitive Strategy Innovation and Leadership.
Multi-domain debugging of embedded IoT Devices, RTE This video demonstrates the multi-domain test capabilities of Rohde & Schwarz oscilloscopes.
Discover some of the key parameters of an oscilloscope and how they impact on the performance in this video series: Product video, RTE, Oscilloscope, Tutorial Video, Rohde & Schwarz R&S Talking about triggering
How Rohde & Schwarz oscilloscopes help you find EMI issues during board design, shortening the time to market. video, oscilloscope, EMI debugging, RTE How Rohde & Schwarz oscilloscopes help you find EMI issues during board design, shortening the time to market.
This video shows how the R&S®RTE oscilloscope with its low-noise frontend and fast update rate can be used to quickly and accurately measure peak-to-peak ripple voltages. The spectrum view provides even deeper insight into the signal.
Modern, capacitive touchscreens as used, for example, in mobile phones are susceptible to common mode noise exhibited by external power supplies (EPS).
17-May-2018
This document describes a method to separate common-mode and differential-mode separation using two oscilloscope channels. This separation approach works without any additional hardware component.
17-Sep-2020 | AN-No. GFM353
R&S®VISA is a standardized software library that allows fast communications over diverse interfaces with a wide variety of T&M instruments that are detected on the network from PC applications.
26-May-2020 | AN-No. 1DC02
This paper explains how to use the Rohde & Schwarz IVI.NET instrument drivers in a Visual Studio environment.
31-May-2016 | AN-No. 1MA268
The R&S®RTx-K50 option expands the addressable range of interface standards by adding decoding capability for standardized and proprietary Manchester or NRZ coded buses.
19-Oct-2020
Increasing demands on power distribution networks have resulted in smaller DC rails, as well as a proliferation of rails that ensure clean power reaches the pins of integrated circuits.
07-Mar-2017
Versatile Software Tool for Rohde & Schwarz Instruments
RSCommander is a versatile software tool for a wide range of Rohde & Schwarz spectrum-, network analyzers, signal generators and oscilloscopes. It allows for automatic instrument discovery, making screenshots, reading traces, file transfer and simple script creation.
24-Dec-2017 | AN-No. 1MA074
From designing a test setup to performing accurate measurements
This application note discusses important aspects of double-pulse test setups as well as how to perform accurate measurements. Double-Pulse testing is a standard test-method.
22-Mar-2021 | AN-No. GFM347
Importance of deep memory in digital oscilloscopes - Rohde & Schwarz oscilloscopes offer industry-leading memory depth.
21-Mar-2017
Secondary surveillance radar (SSR) bridges the gap between communications systems and classic radar systems. Despite the increasing capabilities of mobile communications, SSR remains a major component in airspace surveillance.
17-May-2021
Testing and optimizing low-power designs - Product Flyer
Oscilloscope innovation. Measurement confidence. - Poster
Rohde & Schwarz recognizes the potential risk of computer virus infection when con-necting Windows®-based test instrumenta-tion to other computers via local area net-works (LANs), or using removable storage devices.
27-Jan-2015 | AN-No. 1DC01
This Application Note gives 10 useful Tips & Tricks for the users of Rohde & Schwarz attribute-based instrument drivers.
30-Jan-2017 | AN-No. 1MA228