TM/RTA - Edge A/B Trigger - Remote commands for the trigger level
With active FFT it seems that the timebase setting can not be changed. Is there a way to do that?
I have saved some important screenshots in /INT/SCREEN path. Now I want to save/copy these data on a USB key or my PC.
What is the calculation base for the sample rate on my R&S RTA / RTM series scope when using FFT?
I do RMS measurement on a signal after switching the channels. Even with *OPC? or *WAI the result is implausible: 9.91e+37 . How can I get a correct result?
I want to use the "Remote Display" function of the Instrument View software. Instead of the screen I just see a "white" area. My PC is connected via USB. How can I use it?
When I query the waveform with "CHANx:DATA?" the resolution is just that what is displayed on the screen. But I have manually changed the record length to achieve a high resolution. How do I get the data of the waveform with full resolution?
CAN, trigger, decode, automotive ethernet, RTM, RTO A comparisson between CAN decoding on the R&S®RTM oscilloscope with automotive Ethernet decoding using the K57 option on the R&S®RTO oscilloscope.
This application note describes how to use the R&S®RTO, R&S®RTE and R&S®RTM Digital Oscilloscopes for EUT monitoring of signal forms.
20-Apr-2015 | AN-No. 1MA242
RTB/RTM/RTA: Other units than V or A at channels? RTB, TRM, RTA, RTB/RTM/RTA: Other units than V or A at channels? RTB, TRM, RTA, Related Products
Cursors that follow the waveform
No synchronisation in Auto Trigger Mode
Delta Time Accuracy Calculation for my Oscilloscope
The R&S®RTx-K36 frequency response analysis (Bode plot) option displays the system response to changes in operating conditions, such as supply voltage changes.
13-Aug-2024
How can I find out that the measurement has been finished?
How can I query the waveform data of the serveral segments?
Configuring the Probe Adapter RT-Z2T with remote commands
We want to measure the voltage of the main line with our oscilloscope.
Rohde & Schwarz Getting Started manual for R&S RTA4000 digital oscilloscopes
I use the oscilloscope in RUN continious mode. When I press "STOP" more than one acquisitions are shown. The waveforms are overlayed. Is there a way to prevent this?
When I set the frequency of the arbitrary generator to 10 KHz, the frequency of the output signal is 120 KHz. What is wrong here?
At old scopes there was no trigger necessary to run the X/Y mode. Why does the mode not work if no valid trigger condition is detected?
Models: R&S®RTM3002, R&S®RTM3004, R&S®RTM3002 + RTM-B222, R&S®RTM3004 + RTM-B242, R&S®RTM3002 + RTM-B223, R&S®RTM3004 + RTM-B243, R&S®RTM3002 + RTM-B225, R&S®RTM3004 + RTM-B245, R&S®RTM3002 + RTM-B2210, R&S®RTM3004 + RTM-B2410
Models: R&S®RTM3002, R&S®RTM3004, R&S®RTM3002 + RTM-B222, R&S®RTM3004 + RTM-B242, R&S®RTM3002 + RTM-B223, R&S®RTM3004 + RTM-B243, R&S®RTM3002 + RTM-B225, R&S®RTM3004 + RTM-B245, R&S®RTM3002 + RTM-B2210, R&S®RTM3004 + RTM-B2410
I have compared passive and active probes. It seems that the noise with active probes is higher. What is the reason and what can I do to reduce the noise?
I have exported the waveform into a csv file. When I open the file in Excel, the values are completely wrong. How can I get correct values?
Rohde & Schwarz user manual for the R&S®CampusDashboard lab management software; provides all the information about the software.
Instrument Security Procedures for R&S®RTM3000