785 Results
REAL-TIME RECEIVER TRACE EXPORT FOR R&S®ESW
25-Jul-2024 | AN-No. 1EE27
This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines. Learn more about time domain reflectometry (TDR) and time domain transmission (TDT) for signal integrity applications using the R&S®ZVA vector network analyzer from Rohde & Schwarz.
With IT and OT environments converging, security concerns relating to devices and applications deployed in networked test labs, especially in T&M environments, are growing. The demands on IT security here are manifold and include, for example, remote access to in-house infrastructures, equipment rented from external providers, and the continuous deployment of devices across different time zones.
18-Oct-2022
Measurement of Adjacent Channel Leakage Power on 3GPP W-CDMA Signals with the FSP
12-Jan-2001 | AN-No. 1EF41
ACP Measurement according to IS 54 (NADC) using the FSE Spectrum Analyzers
17-Jan-2002 | AN-No. 1EF32
This application note focusses on signal measurement using the R&S®RTO digital oscilloscopes ant the output of I/Q data for processing.
18-Oct-2016 | AN-No. 1MA249
More frequency bands and larger dynamic ranges increase the number of test points required in characterization and production of the latest RF frontends (RFFE). Actively managing test time and cost while maintaining quality is more important than ever before.
The R&S®FSW and R&S®SMW200A are leading hardware solutions for 5G NR base station tests - set up all required parameters in no time with just a few clicks.
25-May-2021
Fast and Accurate Test of Mobile Phone Boards
29-Aug-2003 | AN-No. 1MA65
Time-of-arrival (ToA) and Time-Alignment-Error (TAE) are important network synchronization measurements to achieve high network quality and performance.This educational note describes how 5G NR is affected by these synchronization requirements.
17-Aug-2021 | AN-No. 8NT05
23-May-2023
Rohde & Schwarz signal generators and analyzers approved by Qualcomm for O-RAN compliant 5G RAN platformsSeveral Rohde & Schwarz test solutions have been approved by Qualcomm Technologies, Inc. in their latest Qualcomm® Development Acceleration Resource Toolkit (QDART) release for testing the Qualcomm QRU100 5G RAN Platform in the 5G NR FR1 frequency range.
13-Feb-2024
Rohde & Schwarz and Autotalks collaborate to verify world’s first 5G-V2X chipset using new capabilities of the R&S CMP180 radiocommunication testerRohde & Schwarz and Autotalks collaborate to verify world’s first 5G-V2X chipset using new capabilities of the R&S CMP180 radiocommunication tester
Capture infrequent events in the spectrum The RTP's Zone trigger allowes as the only oscilloscope in the world to isolate events in the time and the frequency domain.
31-Mar-2022
Rohde & Schwarz presents first automated test solution for high-speed Ethernet cable assemblies up to IEEE 802.3ckNew compliance test automation software from Rohde & Schwarz for IEEE 802.3 cable assemblies allows for precise and time-saving compliance tests of high-speed cables and backplanes according to the IEEE 802.3bj, by, cd and ck standards. The R&S ZNrun vector network analyzer automation suite controls a vector network analyzer and a switching solution from Rohde & Schwarz to provide automated testing of high-speed Ethernet cable assemblies, considerably reducing the testing time and potential errors compared to manual Ethernet cable assembly test methods. Rohde & Schwarz demonstrates the solution for the first time at DesignCon 2022 in Santa Clara, California.
Frequency Hopping for GSM Base Station Tests with Signal Generators SME
01-Jul-1999 | AN-No. 1GPAN28
This application note explains how to synchronize multiple R&S®SMBV100A vector signal generators.
09-Jul-2013 | AN-No. 1GP84
With 400 Mpts for 4 channels and optional 800 for 2 channels, you will capture even more signal time and retain maximum bandwidth at slow time bases – making it perfect for handling a large range of troubleshooting tasks.
Pulse Profile Measurements In this final video we look at a special mode of measurements where the ZNA network analyzer can be used to analyze the pulse in time to study in much higher resolution what is happening during the “on time” of the RF pulse.
Turnkey EMC and antenna test center improves time to market of wireless smart meters Turnkey EMC and antenna test center improves time to market of wireless smart meters With the aim to improve time to market of their wireless smart meter solutions, Kamstrup in Denmark opted for a turnkey EMC and antenna test center from Rohde & Schwarz and Albatross Projects.
R&S®MXO 5 - Evolved for more challenges No longer a trade off between maintaining a high sample rate and capturing time: With a standard 500 Mpts of memory per channel with your R&S®MXO 5 series oscilloscope it is possible to capture longer time periods while maintaining a high sample rate.
This paper will discuss several measurement settings which affect measurement speed and provide suggestions on improving this overall speed.
08-Oct-2020 | AN-No. GFM354
The spectrum settings are independent of the time domain settings yet are fully time-correlated. Configure the spectrum analysis function of the R&S®MXO 4 series oscilloscope by simply entering typical parameters such as center frequency, span or resolution bandwidth (RBW). The spectrum settings are independent of the time domain settings yet are fully time-correlated.
08-Mar-2021
Industrial Radio Lab (IRL) Dresden and Rohde & Schwarz cooperate to research wireless technologies for industry 4.0Rohde & Schwarz provides high performance network scanners to IRL Dresden to explore reliable and resilient wireless technologies for industrial applications. The test equipment is used for distributed real-time radio spectrum and interference monitoring.
Real-time FFT processing in Rohde & Schwarz receivers - Application Brochure Brochures and Data Sheets
07-Jun-2022
Rohde & Schwarz enhances R&S RTP high-performance oscilloscope for even better signal integrity in real timeRohde & Schwarz has paired the outstanding performance of its established R&S RTP oscilloscope with an enhanced user interface and a larger display. The result is an even more flexible oscilloscope in a compact format with a modern look and feel that continues to deliver high-performance signal integrity in real time.
How to measure pulse sequences in time and frequency domain. How to measure pulse sequences in time and frequency domain Video, RTO2000, Oscilloscope, RF pulse train analysis How to measure pulse sequences in time and frequency domain
This document provides the technical specifications of the R&S®FSVR real-time spectrum analyzer.
Up and down Chirp analysis in time and frequency domain. Up and down Chirp analysis in time and frequency domain Video, RTO2000, Oscilloscope, Analysis of complex radar signals Up and down Chirp analysis in time and frequency domain
SwissQual, SmartMonitor, web-based, software, realtime service, quality monitoring, QualiPoc, Android, probes, real time SwissQual, a Rohde & Schwarz company, presented SmartMonitor, a web-based software for realtime service quality monitoring, at the GSMA Mobile World Congress 2016 in Barcelona.