Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
125 Results
Zone trigger, time and frequency domain, RTO2000 The R&S®RTO oscilloscopes’ zone trigger lets you graphically separate events. Define up to eight zones of any shape and logically combine them over multiple channels or by using math functions.
Video, RTO2000, Oscilloscope, 2 Gsample deep memory The R&S®RTO oscilloscopes' acquisition memory can be extended up to 2 Gsample.
RTO2000, MSO, mixed signal option Every R&S®RTO can be enhanced to include a mixed signal option. This enables more signal details thanks to high time resolution over the entire memory depth, as well as precise triggering on signal events.
RTO2000, debugging, EMI When debugging EMI problems in electronic circuits, development engineers face the challenging problem of quickly and accurately identifying and eliminating the sources of unwanted emissions. Many problems can be eliminated during development by using oscilloscopes for EMI debugging.
R&S®RTO2000 Video, application videos, oscilloscope, troubleshooting, mixed signal oscilloscope Rohde & Schwarz at EuMW 2011: Fast, accurate and easy to use oscilloscopes
RTO2000, deep memory, CAN Bus data, decoding, automotive Discover how Rohde and Schwarz oscilloscpes with deep memory can record over a minute of CAN bus data, as displayed on an R&S®RTO.
RTO2000, repetitive measurements, instrument setup The R&S®RTO can save instrument setups for repetitive measurements. Each instrument setup is saved along with a screenshot of the most recent oscilloscope display. To later select a desired instrument setup, simply scroll through the screenshots to find the right configuration.
Oscilloscope bus triggering, RTO2000, bus triggering, history mode, break condition Use the hardware trigger to isolate break conditions. Break conditions can be corellated with their root cause one by one using the History Mode.
Video, RTO2000, Oscilloscope, Measurement of very small currents The R&S®RTE and R&S®RTO oscilloscopes can measure currents down to 100 uA using their low noise and high-sensitivity current probe.
Video, RTO2000, Oscilloscope, Industry-leading mask test Defining masks is easy and flexible with the R&S®RTO.
RTO2000, signal analysis, detailed analysis, deep toolset R&S®RTO oscilloscopes offer over 90 measurement functions. The functions are organized by type into amplitude and time measurements, jitter, eye, histogram and spectral measurements. Statistics, histograms, and trend and track functions facilitate detailed analysis of the measurement results.
RTO2000, spectrum analysis, precise measurements, power measurements Whether you are working with a motor drive, SMPS or power rails, making fast and precise power measurements can be challenging. The many unique R&S®RTO oscilloscope features enable you to make better and faster power measurements.
R&S RTO2000: Documentation at the press of a button R&S®RTO oscilloscopes help you document measurements, including printing and saving screenshots of the screen content, easy to read signal characteristics thanks to clear grid annotations and color-coded labels to highlight anomalies in the diagram.
RTO2000, waveform display, R&S®SmartGrid, complex measurements Use the R&S®SmartGrid function to configure the display. For complex measurement tasks where several screen displays are helpful, you can superposition windows in multiple tabs. All measurement diagrams have labeled scales so you can immediately read important signal characteristics.
RTO2000, debugging, AD converter The R&S®RTO-B1 option offers numerous triggers for debugging and analysis, such as edge, width, pattern and serial pattern. The digital channel resolution of 200 ps makes this channel a precise trigger source.
RTO2000, user interface, toolbar, display, cockpit The advanced user interface enables clear orientation thanks to colour coding, as well as having a high-resolution capacitive touchscreen with gesture support. The toolbar at the top of the screen provides access to frequently used functions such as measurements, zoom and FFT.
RTO2000, SPI, bus decoding, serial protocols R&S®RTO oscilloscopes offer a variety of tools for serial interface analysis. The configuration for any given protocol is accomplished in just a few steps starting from the app cockpit. Just select the bus you want to decode, configure the bus settings and set the reference levels to 50 %.
Oscilloscope bus debugging, RTO2000, bus debugging, UART, RS232, RS485 Let your Oscilloscope decode your UART/RS232/RS485 interfaces for you! So you can quickly understand the data and correlate the data content with the electrical signal.
Video, RTO2000, Oscilloscope, Capturing of intermittent RF signals with the Zone Trigger This video demonstrates this unique capability of the R&S®RTO on the example of a frequency hopping signal.
Webinar, RTO2000, Automotive Ethernet compliance testing This webinar presents details on the individual test cases of the compliance test and provides useful information on the required test setup.
Signal faults, waveforms/s, RTO2000, ASIC R&S®RTO oscilloscopes display up to 1 million waveforms/s. To make this possible, Rohde & Schwarz developed an ASIC with optimized signal processing. R&S®RTO oscilloscopes enable you to quickly and reliably detect sporadic signal faults.
Video, RTO2000, Oscilloscope, Power integrity test Today’s highly integrated electronic devices use smaller voltage levels and therefore require much smaller ripple levels on the power rails for reliable operation.
RTO2000, toolbar, measurement functions, fast access The toolbar at the top of the screen provides access to frequently used functions such as measurements, zoom and FFT. Configure measurement in a few seconds by simply activating the measurement setup in the toolbar and choosing the desired measurement function and source channel in the sidebar.
RTO2000, jitter analysis, signal integrity measurements R&S®RTO oscilloscopes are ideally suited for jitter measurements. The sensitive, broadband, low-noise frontend combined with the high-precision, single-core A/D converter ensures exact results. Another strength of R&S®RTO oscilloscopes is their wide range of analysis options.
Video, RTO2000, Oscilloscope, Testing conducted emission in the R&D lab This video shows how the powerful spectrum analysis features in the R&S®RTO oscilloscope can be used to verify conducted emission levels relative to the requirements during development thereby ensuring passing results in the compliance laboratory.
The high definition mode (HD mode) activates configurable lowpass filtering of the signal after the A/D converter, increasing the vertical resolution to up to 16 bit. 16-bit, low noise, RTO2000, high definition, precise measurement The low-noise frontend and 10 GHz single-core A/D converter are the foundation for the extraordinarily high measurement accuracy and dynamic range of the R&S®RTO oscilloscopes
This results in minimal trigger jitter without postprocessing correction as well as high sensitivity that can be extended up to 16 bit in HD mode. 16-bit, low noise, RTO2000, high definition, precise measurement The unique digital trigger system from Rohde & Schwarz uses the sampling point of the A/D converter in the acquisition path so that the trigger system's input data is identical to the displayed
Zone trigger, time and frequency domain, RTO2000, set up Define up to eight zones of any shape and logically combine them over multiple channels or by using math functions. Depending on how the zones are defined, a trigger signal is activated when a signal either intersects or does not intersect the zone.
Terrestrial air navigation systems provide safety critical service seamlessly. Learn more about constant performance monitoring & measurements for organizations.
Terrestrial air navigation systems provide safety critical service seamlessly. Learn more about constant performance monitoring & measurements for organizations.