Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
3266 Results
How test and measurement and network encryption enable new quantum technology applications.
Rohde & Schwarz cares about its employees and supports them to quickly settle into the pandemic’s work reality.
Read stories from the experts and get more insights into our state-of-the-art mobile network testing solutions for field services and interference hunting.
First choice for airborne platforms Rohde & Schwarz software defined airborne radios are in operation in more than 70 different airborne platforms. More than 8,000 radios are delivered for jets, transporter aircrafts, helicopters and unmanned aerial vehicles.
Use the 5G site testing solution from Rohde & Schwarz to ensure correct network performance and QoS delivered to end users over 5G networks.
NB-IoT carriers are very difficult, if not impossible, to find. The Automatic Channel Detection (ACD) feature in R&S®ROMES4 does the job automatically.
Indoor deployments help operators meet the fast growing data demands in mobile networks. Learn how to plan and deploy small cell networks reliably.
Tests targeting mobile data applications, such as Facebook, provide network providers with insights into QoE to ensure a smooth user experience.
This paper provides an important insight into the design and measurement challenges around the key topic of 5G New Radio in collaboration of a number of industry partners.
26-Nov-2018
The video demonstrates Bluetooth 5 measurements using the R&S CMW270 wireless connectivity tester. The video demonstrates Bluetooth 5 measurements using the R&S CMW270 wireless connectivity tester. Learn how the physical layer has changed with Bluetooth 5 and how to perform transmitter and receiver measurements using the R&S CMW platform.
Install and maintain your BTS with ease of use and efficiency. Learn more about return loss and passive intermodulation.
Rohde & Schwarz offers a compliance test solution using the R&S®RTE or the R&S®RTO oscilloscope.
27-Jan-2016
The R&S®EVSG1000 and R&S®EVSF1000 are signal level and modulation analyzers that reliably analyze GBAS systems during ground and flight inspection when used together with the R&S®EVSG-K4 option.
27-Jun-2019
A simple concept with Azure IoT
This document describes an approach how to establish a remote connection between the instrument and the cloud using an IoT broker.
15-Dec-2020 | AN-No. GFM319
Read this educational note and dive into the discussion about the six most important transformer measurements: turns ratio, mutual inductance, phase angle, primary and secondary inductance, leakage inductance, and interwinding capacitance.
28-Feb-2024
F2L, Field-to-Lab, VDT, Virtual drive test Reduce time and cost by verifying important device KPIs in lab under realistic network conditions using R&S CM360o Field-to-Lab solution for 5G.
Using MATLAB for Remote Control and Data Capture with R&S Spectrum and Network Analyzers
24-Sep-2007 | AN-No. 1EF46
This application note addresses the diverse possibilities of interoperability between Rohde & Schwarz power sensors and Rohde & Schwarz signal generators. All current and many legacy Rohde & Schwarz signal generators offer the capability of directly connecting power sensors. This enables power measurements without the need of a base unit or separate PC to display the readings. Furthermore, sensors can be used for special tasks like filling a user correction table or continuously controlling levels at crucial points in the measurement configuration.
31-Aug-2023 | AN-No. 1GP141
I would like to do EMI measurements with a Probe. The thing is that I don’t have a "Probes” section in Device List menu. For instance within this menu, I have Generators, Receivers, etc. but not “Probes”.
The video demonstrates how R&S®ZVH can fulfill some of the field task conveniently using Wizard function. The video demonstrates how R&S®ZVH can fulfill some of the field task conveniently using Wizard function.
CERTIUM® NETWORK - Mediacenter
The student team from Cellsius Project H2 uses an R&S®RTA4004 oscilloscope to validate the functionality of its inverter.
Transient Measurements on GSM/PCN Synthesizers
03-Jun-1998 | AN-No. 1EF08
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
ACP Measurement according to IS 54 (NADC) using the FSE Spectrum Analyzers
17-Jan-2002 | AN-No. 1EF32
This paper will provide an overview of the current status of the ITS worldwide with a focus on the IEEE 802.11p PHY. Additionally, the paper provides information on test and measurement solutions for devices and components used in ITS.
23-Jan-2014 | AN-No. 1MA152
We are using the HMC8012 for automatized tests. I have tried using both the fetch as well as the read commands, but the response time from the device is still about 1 second before any value is returned. Is it possible to have a faster response time than this?
When I try to update my HMP series Power Supply, the updater tells me "Wrong or no device detected! - Process abort". What can I do to make it work?
The overall concept is explained using a product demo of a 5G TSN juggler which shows a deterministic low latency communication via 5G and ethernet using time sensitive networking(TSN).