Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1110 Results
Rohde & Schwarz presents a customizable solution for testing barometric performance to ensure z-axis accuracy in line with FCC regulations.
24-Jun-2021
This application note describes the noise figure measurement using the R&S Vector Network Analyzers of the ZVA and ZVT series. It explains the concept of measuring noise figure without the need for a characterized noise source. Furthermore, it discusses different measurement applications and the respective setup and implications. Some examples guide through the instrument setups and show measurement results as well.
27-Oct-2010 | AN-No. 1EZ61
Radio frequencies in bands around 28 GHz are being discussed as candidates for mobile communications of the fifth generation (5G). Beam steering will be a key feature in the context of 5G. It will be a major challenge to test the beam steering capabilities of base stations and user equipment in every phase from research and development through production. Conducted measurements will be mainly replaced by over-the-air measurements of electromagnetic radiation. Rohde & Schwarz offers the R&S®NRPM Over-the-Air (OTA) Power Measurement Solution that perfectly fits such measurement needs.Part of this solution are the R&S®NRPM-A66 antenna modules. They have integrated diode detectors. Thus, there are no cables between the antenna and the detector as in traditional setups. This avoids high and potentially unknown RF losses. The R&S®NRPM-A66 antenna modules with their integrated diode detectors are factory calibrated, which means that the user does not have to calibrate them to achieve highly accurate measurement results.This application note contains theoretical background on OTA power and pattern measurements. It gives step-by-step instructions for the verification of the power level and the radiation pattern of a device under test (DUT) in comparison to a golden device, and it presents an approach for verifying the accuracy of beam steering.
29-Aug-2017 | AN-No. 1GP118
An easy-to-setup test solution for high speed multichannel acquisition for 5G NR signals
04-Mar-2020
In this day and age of internet of things, more and more devices are connected to the local network, making it even more difficult for the IT department to monitor them. Rohde & Schwarz instruments are also increasingly accessed via their LAN interface, which provides additional convenience features such as remote desktop, SMB file transfer or a web interface. To make it easier to monitor the use and status of instruments, some devices offer a software option, the Health and Utilization Monitoring Service (HUMS).HUMS can be accessed via SNMP and REST (HTTP) and provides all necessary information about the health status and utilization over time in many details.This application note describes how to access HUMS and what data is provided.
11-Jan-2021 | AN-No. GFM336
Phase stability over time is a key characteristic for phase-coherent signals. A common 1 GHz reference signal maintains high phase stability between the RF outputs of multiple R&S®SGT100A SGMA vector RF sources.
09-Jan-2017
When analyzing the robustness of data transmission systems, jitter is a key indicator. It is recommended to use jitter measurement instruments for both the time and frequency domain in order to differentiate between fast and slow moving artifacts.
22-Aug-2017
Frequency converters e.g. in satellite transponders need to be characterized not only in terms of amplitude transmission but also in terms of phase transmission or group delay, especially with the transition to digital modulation schemes. They often do not provide access to the internal local oscillators. This application note describes a method using the R&S®ZNA analyzer family to measure group delay of mixers and frequency converters with an embedded local oscillator very accurately. The key aspect of this new technique is that the network analyzer applies a 2-tone signal to the frequency converter. By measuring the phase differences between the two signals at the input and at the output, it calculates group delay and relative phase.
11-Jul-2019 | AN-No. 1EZ81
R&S®Server-Based Testing helps reduce test times for workloads that can be parallelized. 5G New Radio (5G NR) multicarrier signals are an ideal workload because each component carrier can be analyzed independently and in parallel. In an example EVM measurement, scenario test times are reduced significantly even when receiving I/Q data from just a single instrument.
13-Sep-2021
This Application Note describes testing S-parameters under pulsed conditions with the R&S®ZVA vector network analyzer and either the ZVAX24 Extension unit with pulse modular option or the R&S®SMF signal generator with pulse modulator as a signal source.In addition a constant power level calibration for applications requiring high drive power for test and measurement of device under test (DUT) is also included. A LDMOS S-band radar power transistor is used as example DUT. The pulse profile mode of the R&S®ZVA is used to analyze the time-dependent behavior of the DUT.
11-Apr-2013 | AN-No. 1MA126
R&S®CMWcards is an intuitive and user-friendly software application that makes NB-IoT OTDOA positioning design verification easier than ever.
26-Nov-2018
Power converter and inverter designs for higher power levels are usually based on hard switching half bridge configurations. In such setups, users must pay particular attention to proper switching operations to prevent shoot-through events. Setting up complex real-time trigger conditions using the R&S®RTE and R&S®RTO oscilloscopes increases the test coverage and robustness of converter and inverter systems.
10-Aug-2020
NGE100B, HMC804x, HMP2000, HMP4000, HM8143, NGL200, NGM200, M3SR IN4000A, Power supplies, DC Power supplies, The arbitrary waveform feature o Rohde & Schwarz solutions allow you to simulate device behaviors and replaces basic standalone arbitrary waveform generators. Emulate real-world scenarios with Rohde & Schwarz power supplies NGE100B, HMC804x, HMP2000, HMP4000, HM8143, NGL200, NGM200, M3SR IN4000A
04-Nov-2019
This application note is based on collaborative work between Cadence and Rohde & Schwarz.The focus is on understanding as early as possible in the design process performance enhancements through linearization of non-linear devices, in our case the RF power amplifier (PA). In other words, what performance benefits can be reached with linearization techniques such as digital predistortion (DPD). Typically, this is investigated when the device is available and physical RF measurements are conducted. In this application note, it is looked at earlier in the design process while using electronic design automation (EDA) such as Cadence® AWR® Visual System Simulator™ (VSS) software. The goal is to allow an RF designer to evaluate the linearizability of his design without in-depth knowledge of DPD algorithms. In the end, the designer can get closer to the optimal efficiency with earlier access to DPD, while at the same time improving time-to-market.The application note brings code examples and an exemplary setup for VSS software to provide an easy start to replicate and use the described procedure.
20-Apr-2022 | AN-No. 1SL383
Load pull is a powerful method for characterizing RF power amplifiers through impedance variation. Load pull enables model extraction and validation as well as performance, ruggedness and efficiency testing.
02-Sep-2020
This educational note covers the theory and practice oscilloscopes based on concrete measurement examples that address authentic everyday tasks.The theoretical portion of this paper begins with an explanation of the basic operating concepts for oscilloscopes, followed by a discussion of the most important parameters to be considered when setting up and performing the exercise measurements. The practical portion of the educational note contains detailed measurement tasks that can be performed by small groups in the university lab. These exercises are intended to demonstrate and reinforce the knowledge gained in the theoretical portion. The exercises build upon one another and demonstrate measurement tasks that are frequently encountered by engineers in daily work.
16-Jan-2018 | AN-No. 1MA265
This application note demonstrates the use of the Measurement Receiver to calibrate the signal output level of a Signal Generator.Calibration in this application is a two-step process.► The absolute output level of the signal source, at a fixed level, is measured using a thermal power sensor (e.g. NRP50T), which in turn outputs its reading to the FSMR.► Output power calibration over a wider dynamic range (to lower power) is performed by connecting the FSMR to the signal source directly, and sweeping the power of the signal source.The FSMR offers a nominal total measurement uncertainty of <0.015 dB +/- 0.005 dB per 10dB step. At 1GHz, the power measurement range covers -152 dBm to +30 dBm. It is this intrinsic linearity, that the accuracy of the calibration relies upon.Absolute power measurement uncertainty, for the NRP50T thermal power sensor used in this Application Note, is 0.040 dB to 0.143 dB.This process may be repeated at multiple frequencies. Calibration values are automatically stored and managed by the FSMR. Measurement frequencies for calibrations are stored, will be automatically recalled by the FSMR, by re-selection of those frequencies.
31-Dec-2021 | AN-No. 1SL377
Make more accurate power rail measurements.
09-Jul-2020
Performing precompliance measurements on power supplies requires using a line impedance stabilization network (LISN) for results that can be compared to limit values. While LISNs are standard in any precompliance lab, often no LISN is available for early R&D testing. If high accuracy is not your goal and you just need a simple tool for debugging, you can build your own LISN. Rohde & Schwarz oscilloscopes with powerful FFT analysis, are ideal for optimizing EMI filters or debugging unwanted emissions during development.
14-Jan-2021
The Doherty Amplifier continues to be rolled out in an increasing number of TxFE (Transmit Frontend) applications, as the quasi-linear amplifier architecture of choice.The advent of 5G, with its inevitable microwave or millimeter wave air interface, increase the design challenges associated with its construction; not least of all because of the potential for increased dispersion in the constituent amplifiers and combiners.This application note describes a measurement-based development methodology by which the Doherty Amplifier may be enhanced, increasing performance and/or performance bandwidth. This methodology is supported with a working example.The methodology may also be extended to balanced, spatially combined and anti-phase (so called "pushpull" or "differential") amplifiers, the latter often itself nested in Doherty configurations.The R&S®Quickstep sequencing software may be downloaded from:
26-Sep-2016 | AN-No. 1MA279
The R&S®RTO / R&S®RTE oscilloscope is a valuable tool for analyzing EMI problems in electronic designs. High input sensitivity, high dynamic range and a powerful FFT implementation are key features for capturing and analyzing unwanted emissions.
26-Feb-2015
This application note describes Methods of Implementations (MOI) for precise, fast and error-free compliance testing of high-speed backplanes and direct attach copper cables (DAC) according to IEEE 802.3bj, IEEE 802.3by, IEEE 802.3cd and IEEE 802.3ck, based on 25 Gb/s, 50 Gb/s and 100 Gb/s signaling per lane with vector network analyzers from Rohde & Schwarz.
07-Apr-2021 | AN-No. GFM356
Rohde & Schwarz signal generators present a compact easy-to-use solution for generating phase coherent signals. Different generator models can be coupled to optimally fit user requirements in terms of number of phase coherent channels and RF frequency range.This application note explains how to generate phase coherent signals, details what to consider and how to best calibrate the relative phases and timing between the individual channels. This document also presents various measurements of the phase stability over time for different RF frequencies.
07-Sep-2016 | AN-No. 1GP108
CST® Filter Designer 3D, which is part of the CST Studio Suite® simulation software from Dassault Systèmes, is a complete synthesis tool for filters and diplexers. It provides a range of solutions throughout the design process of coupled resonator filters and even beyond with its VNA based tuning capability. CST Filter Designer 3D assists in tuning filter hardware, significantly reducing the time for optimizing a device to meet the expected specifications. An attractive instrument to obtain fast data reading for realtime filter tuning is the R&S®ZNB vector network analyzer from Rohde & Schwarz.
27-Nov-2019
Rapid and accurate verification of beamforming weights is required for example, for codebook generation or beamforming algorithm development or verification. This document describes the unique application of Rohde & Schwarz VNA (Vector Network Analyzers) to fully characterize the passive part of multi-element antennas intended for beamforming.A range of R&S VNA models are optionally equipped with multiple independent sources, whose relative amplitude and phase may be arbitrarily controlled ("defined coherence mode"), in addition to frequency and true time delay. These sources may be connected to individual elements of a multi-element antenna to derive and verify transmit (Tx) mode beamsteering and beamforming operation.The R&S®ZVA in "Defined Coherence Mode" can electronically be switched to / from the conventional S-parameter mode. Therefore, Sparameter and beamforming measurements may be performed efficiently within a single connection cycle of the antenna.Multiple VNA may be daisy-chained, to extend the concept shown to support an arbitrary number of ports.The R&S®Quickstep sequencing software may be downloaded from:https://www.rohde-schwarz.com/software/quickstep/
20-Mar-2017 | AN-No. 1MA278
High-precision two-quadrant power supplies generate current profiles and simulate batteries
10-Dec-2020
For measurements of non-connectorized devices, test fixtures, probes or other structures are used to adapt from the coaxial interface of the test setup to the device under test (DUT). For accurate measurements of the DUT, these lead-ins and lead-outs need to be characterized, so that their effects can be mathematically removed, i.e. de-embedded from the measurement results.This application note provides practical hints to accurately characterize and de-embed these lead-in and lead-out structures with R&S Vector Network Analyzers ZNA, ZNB, ZNBT and ZND. As de-embedding is also essential in other test equipment like oscilloscopes, etc., this guide also describes, how lead-ins and lead-outs can be accurately characterized with a VNA and then exported as an S-Parameter file to be used by other test instruments.
19-Sep-2022 | AN-No. 1SL367
Generation of wideband digital modulated signals in V-band and above is a challenging task and typically requires a set of multiple instruments. This application note aims at simplifying the task and looks into the analysis part as well. Latest signal and spectrum analyzers like the R&S®FSW67 and R&S®FSW85 are first to allow use in V-band up to 67 GHz and E-band up to 85 GHz respectively without external frequency conversion. Up to 8.3 GHz of modulation bandwidth can be covered using the R&S®FSW-B8001 option. Millimeter wave use of analyzers ranging from 26 GHz up is shown. Application note 1MA217 describes V-band signal generation and analysis up to 500 MHz modulation bandwidth. This application note expands modulation bandwidth up to 2 GHz and covers both V- and E-band examples.
18-Jun-2015 | AN-No. 1MA257
The R&S®FSWP phase noise analyzer is a highend instrument designed to accurately analyze noise performance of key components in radar and communications systems. Using phase noise measurements, a device’s large-signal noise figure can be derived under real-world operating conditions.
27-Oct-2017
The R&S®ZNB vector network analyzer simplifies instrument configuration and calibration using the mixer measurement wizard and SMARTerCal.
01-Oct-2013