Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
752 Results
While Mobile phones are allowed to require approximately 3 time slots for switching from transmission to reception, base stations must be able to transmit and receive at a new frequency in every time slot in the frequency hopping mode. This behaviour must of course be tested and measurements carried out on the base station transmitter and receiver. Since there is no signal generator which is able to settle at different frequencies from one to the next time slot with GSM modulation, a solution to this problem was found by linking two Signal Generators SME in such a way that they alternately provide signals at different frequencies.
01-Jul-1999 | AN-No. 1GPAN28
The R&S®SMW200A together with the R&S®FSW is a state of the art testing solution that significantly reduces the required hardware for testing power amplifiers with envelope tracking and/or digital pre-distortion. This application note introduces the test solution in detail and presents corresponding measurement examples.
25-Sep-2014 | AN-No. 1GP104
An automated test solution based on the R&S®CMW wideband radio communication tester fully supports the new test cases for real-time submeter positioning.
10-Jun-2022
Rohde & Schwarz has a tool that can configure all instruments and channels from one interface to maintain an overview of the states and measurement values for all channels.
28-Apr-2023
Its dual-path concept and high-power signal generation up to 20 GHz make the R&S®SMW200A vector signal generator ideal for efficient testing of blocking characteristics
30-May-2014
Balanced RF components are advantageous compared to traditional single-ended components, since they cause less EMI, and are less susceptible to EMI. This application note describes the fundamental concepts of differential and common mode signals and of mixed-mode parameters, which are essential for balanced components. Techniques for the measurement of mixed-mode parameters are presented. Examples show the features implemented in the ZVB for balanced device measurement.
20-Sep-2004 | AN-No. 1EZ53
For establishing a WLAN connection between R&S®CMW and device under test (DUT), the WLAN properties at the R&S®CMW have to be adapted to the test conditions. These can vary in several aspects, particularly due to the different WLAN standards and characteristics of the DUT. This document describes the critical parameters and provides step-by-step procedures for the configuration.
08-Dec-2015 | AN-No. 1C106
This operation guide describes how to measure HSUPA test cases according to 3GPP TS 34.121 V8.0 with R&S®CMU200. Setting files according to the test requirements are attached.
08-Oct-2009 | AN-No. RCS0712-0053
Noise sources used for noise figure and gain measurements are typically controlled by the spectrum analyzer or noise figure meter instruments and are calibrated with their ENR value (Excess noise ratio). While this external control and the use of ENR values is common in noise figure test, it may be difficult in system applications where the noise source control is not available, and the use of ENR values is replaced with the values for the noise output power of the noise source. The calculation of the output power for the noise source requires to know the P_hot value (hot power) which is not a common specification for noise sources used in test and measurement applications.This application note describes a technique to perform a calibrated noise power measurement (P_hot) with spectrum analyzers and noise sources. The next sections will give further details.
31-May-2022 | AN-No. 1EF113
The foregoing application note is intended for everyone who desires to become more familiar with the use and upload of custom data in ARB, digital modulation and RF list mode. Particularly, this note describes the instruments R&S® SMW200A, R&S® SGT100A, R&S® SMBV100A, R&S® SMU200A, R&S® SMJ100A and R&S® SMATE200A and provides an overview of already available solutions as well as it gives hints for the writing of own applications. Please also see the application note 1GP88 for the ARB Toolbox software and the application note 1GP96 for the CDM-Toolbox software.
22-Dec-2010 | AN-No. 1GP62
This document describes WLAN tests which rely on communication (signaling) between R&S®CMW and device under test (DUT) and on transmission of packet data over WLAN. On the R&S®CMW side the WLAN Signaling application is required, for some tests also the Data Application Unit (DAU).The test principles and the necessary settings are explained and background infor-mation is given. Step-by-step procedures are provided for the main configuration tasks.
08-Feb-2016 | AN-No. 1C107
Rohde & Schwarz offers unique one-box solutions for reliable testing of air navigation systems such as ILS, VOR and DME.
04-Nov-2010
RF performance measurements for Wi-Fi 7.
30-May-2022
Due to recent security concerns, ultrawideband (UWB) technology is making its way into automotive key fobs. Rohde & Schwarz offers a flexible test solution for the high demands of R&D and highthroughput production environments.
21-Mar-2017
The R&S®CMW Wideband Radio Communication Tester offers an elaborate parametric test concept, including all RF test cases up to Bluetooth®5, that makes this flexible test platform ideal for designing and verifying Bluetooth® Low Energy (LE) circuitsand modules.
27-Jan-2017
The R&S®FSW signal and spectrum analyzer with the R&S®FSW-K160R realtime option and the R&S®FSW-K6 pulse measurement option is ideal for testing modern radars.
04-Jul-2013
Rohde & Schwarz presents the R&S®ATS1000 antenna test system, a highly accurate solution for testing 5G antennas up to mmWave frequencies in a mobile shielded chamber.
17-Oct-2017
LTE-M (also known as Cat M1) is a machine type communication (MTC) standard for IoT applications, specified by 3GPP. This application note provides and overview of the technology, the details of the standard and summarizes the R&S®TSMx scanner features for LTE-M measurements.
26-Jul-2019 | AN-No. 8NT04
Sequencer Software Tool
20-Feb-2015
This application note describes Methods of Implementation (MOI) for precise, fast, and error-free compliance testing of USB Type-C to Type-C cable assemblies supporting USB4 Gen3, USB4 Gen2, USB 3.2 Gen2, USB3.2 Gen1, and USB2.0.
30-Nov-2023 | AN-No. 1SL405
Rohde & Schwarz presents a customizable solution for testing GNSS receivers to ensure a certain resilience against (legal) interference from neighboring bands.
18-Jul-2017
Its dual-path concept plus its ability to duplicate baseband signals make the R&S®SMW200A vector signal generator ideal for efficient GSM/EDGE AMsuppression conformance testing.
28-Feb-2017
High sampling rate and automatic pulse analysis make the R&S®NRP-Z8x wideband power sensors ideal for time-domain analysis of radar pulses.
06-Aug-2013
An easy-to-setup test solution for high speed multichannel acquisition for 5G NR signals
04-Mar-2020
As phase noise becomes an increasingly important system-level specification for electronic test equipment, communications systems, and radar systems. It is not only important to quantify the noise produced by oscillators, but also the noise added by each component in the signal processing chain. This application note reviews the fundamentals of residual or additive noise and addresses measurement techniques for determining the amplitude (AM) and phase noise added by two-port devices such as: amplifiers, mixers, block frequency converters, multipliers, dividers, and frequency synthesizers.Additionally, the Rohde & Schwarz FSWP phase noise analyzer will be introduced and a discussion of residual noise measurement techniques for the above-mentioned devices will be provided.
09-Oct-2017 | AN-No. 1EF100
The simple network management protocol (SNMP) can be used in a wide range of applications, as described in Rohde & Schwarz Application Note 7BM65 “The Simple Network Management Protocol: Remote Controlling for Monitoring Devices“. In particular, the option of centrally managing monitoring sensors – such as the R&S DVM for RF and baseband signals in digital broadcasting – shows the potential of this technology. However, the protocol alone is not enough to achieve this management functionality. Specialized management applications are needed that carry out the SNMP requests and display the results graphically. This application note and the associated SNMP example application will show how the R&S DVM family can be used for this type of application. Rohde & Schwarz customers can use the included source code (programming language: C#) to make the modifications needed for their own situations.
31-May-2007 | AN-No. 7BM66
This Application Note describes the basic operating principles of distance measurement equipment (DME) and tactical air navigation (TACAN) for distance and bearing measurements in aviation along with diverse test possibilities for maintenance of DME/TACAN ground stations.Some tests are performed on the ground (on the RF port of the DME or TACAN station or in the field via antenna) while others require flight inspection.The R&S®EDS300 DME/pulse analyzer is the specialist for flight inspection and simultaneous measurement of up to 10 different DME’s and can also be used for monitoring tasks on ground (e.g. far field monitoring of all DME’s of an airport).The R&S®EDST300 TACAN/DME analyzer focusses on commissioning and regular maintenance checking of TACAN and DME ground stations and battery operated field measurements in the immediate environment of the station.
28-Mar-2017 | AN-No. 1EF91
This document is divided in two parts and starts with an introduction in AC-DC conversion principles in general. It will present the most common circuits used for different power levels. The switching mode power supply (SMPS) converter will be the main focus as they are used everywhere in the electronics. Especially the flyback converter design in different flavors are highlighted. Nevertheless, all measurements are also applicable for other SMPS converter designs operating at higher power levels.In the second part of this document, most relevant testing methods and procedures of an AC-DC converter are highlighted. For each testing section, a fundamental part will be upfront discussed and it is followed by a presentation of a suitable measurement method. In this second part, the device under test (DUT) is considered as black box device and thus the structure is similar. Therefore, the testing parts consists of methods related to input tests, output tests and a combination of both like efficiency. Of course, some test performed at the output of the converter are also relevant for DC-DC converter, e.g. the validation of the output ripple.
14-Nov-2022 | AN-No. 1SL387
This application note describes the basic frequency filter measurements that are often required during service repairs, during development of simple circuits and for training purposes. These measurements do not always require high-end T&M equipment. Instruments in this class typically offer a very wide range of measurement functions coupled with the best-possible RF performance. However, these features are not necessary for simple applications. This application note therefore describes measurements using instruments from the cost-effective Rohde & Schwarz Value Instruments series. The instruments in this series offer the measurement accuracy demanded by quality-conscious users plus easy operation and all of the functionality needed for everyday measurement tasks.
27-Mar-2015 | AN-No. 1MA243