156 Results
VNA - do I really need a sliding match for calibration?
How can I change the display resolution when I use an external monitor?
Changing the update display rate of a sweep with many sweep points.
R&S ZCWM-570 Technical Information
Calibrating a vector network analyzer (VNA) with different connectors on each port
Converting the real and imaginary numbers to magnitude in dB and phase in degrees.
R&S®ZVAX-TRM User Manual
R&S®ZVAX-TRM Instrument Security Manual
What is the correct pin layout of the DC inputs on the network analyzer's rear panel?
Sending a remote Control Command internally
R&S ZCxxx Converter Power Supply User Manual
R&S®ZVAX24 Quick Start Guide
I have set my VNA to single sweep mode and switched on averaging with a factor of 10. But when I restart the single sweep, it stops after 1 sweep and the averaging is not done.
Rohde & Schwarz Getting Started for the R&S ZCxxx frequency converters
I query the values of a trace using scpi commands. But I get the y-values only. Is there a possibility to get the y-values also (frequency)?
I trigger this single sweep with the RSZVB_Send_Trigger_and_Wait_for_OPC driver, but this driver does not wait for the complete 10 sweeps. If I don't use averaging, this program is works.
How can I switch from remote to local state via remote control?
TDR, TDT, ZVA vector network analyzer This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines
How do I calculate these frequency points when I have a logarithmic sweep and know the center frequency, the span and the number of sweep points?
I have used my TRL calibration kit with my ZVA before. Now I want to use also with my ZNB. But when I try to load the data of the calibration kit into the ZNB, the above error message is shown.
R&S ZV-WR02/WR03/-WR05 Technical Information
TDR, TDT, ZVA vector network analyzer, This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines.
The R&S®ZVA vector network analyzer in combination with the R&S®ZVAB-K30 noise figure measurement option simplifies noise figure measurement, a key parameter for receiver performance evaluation.
TDR, TDT, ZVA vector network analyzer, This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines.
TDR, TDT, ZVA vector network analyzer This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines.
R&S ZV-WR06/-WR08/-WR10/-WR12/-WR15 Technical Information
Rohde & Schwarz Technical Information for the R&S ZV-Z129/-Z135/-Z170 calibration kits.
ZVA Vector Network Analyzers, PIM, Rohde & Schwarz demonstrated fast and accurate passive intermodulation (PIM) testing of duplex filters at the European Microwave Week 2013 in Nuremberg.
This application note describes how to configure a Rohde & Schwarz Network Analyzer to make spectral measurements directly on a device under test.
16-Mar-2012 | AN-No. 1EZ62
This application note describes the techniques to measure the dielectric properties of materials using a vector network analyzer. It also shows methods for converting the s-parameters to dielectric properties.
23-May-2012 | AN-No. RAC-0607-0019