Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
514 Results
Explore particle acceleration solutions from test and measurement experts. Trust our industry-leading equipment to meet particle accelerator test requirements.
Benefits and advantages Benefits and advantages Video, RTO2000, Oscilloscope, Realtime deembedding Benefits and advantages
For this video, we will be using a 2 GHz R&S®RTO oscilloscope, an 8 GHz R&S®ZND two-port VNA as well as the R&S®ScopeSuite automated test software. Webinar, Automotive, Ethernet This webinar will focus on 1000BASE-T1 automotive Ethernet compliance testing based on the Open Alliance (OA) TC8 specification for the physical layer.
Unique trigger capability Unique trigger capability Video, RTO2000, Oscilloscope, Triggering Unique trigger capability
03-May-2023 | Press Release | Test & measurement
Rohde & Schwarz demonstrates solutions for particle accelerators at IPAC’23 in VeniceAt IPAC’23 in Venice, Italy, Rohde & Schwarz demonstrates solutions that meet high precision particle accelerator requirements, address challenges in elementary particle research, particle therapy applications, material characterization, precise beam forming and monitoring as well as safe storage.
Easy configuration of frequency domain analysis Easy configuration of frequency domain analysis Video, RTO2000, Oscilloscope, Responsive FFT and spectogram Easy configuration of frequency domain analysis
The radio unit activity versus power consumption is monitored using the R&S RTO oscilloscope to detect short power pulses or spikes. The results make it easy to evaluate energy efficiency measures such as advanced sleep modes and provide ratings for radio units based on their power consumption.
Shown on a USB 3.1 Gen1 device Video, RTO2000, Oscilloscope, Signal integrity debugging Shown on a USB 3.1 Gen1 device
Power rail probe in combination with high performance oscilloscope Video, RTO2000, Oscilloscope, Power integrity debugging Power rail probe in combination with high performance oscilloscope.
How to analyze basic paramters of pulsed RF signals Video, RTO2000, Oscilloscope, How to analyze basic paramters of pulsed RF signals
How to perform signal integrity debugging on a DDR3 device Video, RTO2000, Oscilloscope, DDR3 DDR3 signal integrity debugging
How to measure pulse sequences in time and frequency domain Video, RTO2000, Oscilloscope, RF pulse train analysis How to measure pulse sequences in time and frequency domain
Scopefield - Poster
Up and down Chirp analysis in time and frequency domain Video, RTO2000, Oscilloscope, Analysis of complex radar signals Up and down Chirp analysis in time and frequency domain
Russian version - времени простоя цифрового осциллографа на измерения
How to use realtime deembedding on a USB 3.1 Gen1 device video, oscilloscope, RTO2000, USB 3.1 How to use realtime deembedding on a USB 3.1 Gen1 device.
This document is divided in two parts and starts with an introduction in AC-DC conversion principles in general. It will present the most common circuits used for different power levels. The switching mode power supply (SMPS) converter will be the main focus as they are used everywhere in the electronics. Especially the flyback converter design in different flavors are highlighted. Nevertheless, all measurements are also applicable for other SMPS converter designs operating at higher power levels.In the second part of this document, most relevant testing methods and procedures of an AC-DC converter are highlighted. For each testing section, a fundamental part will be upfront discussed and it is followed by a presentation of a suitable measurement method. In this second part, the device under test (DUT) is considered as black box device and thus the structure is similar. Therefore, the testing parts consists of methods related to input tests, output tests and a combination of both like efficiency. Of course, some test performed at the output of the converter are also relevant for DC-DC converter, e.g. the validation of the output ripple.
14-Nov-2022 | AN-No. 1SL387
Generating models with a VNA and using these on an oscilloscope via the deembedding
23-May-2023 | AN-No. 1SL393
Video, oscilloscope, RTO2000, Time delay analysis of multiple wideband RF signals Analysis of multiple RF signals, which are typically used e.g. for direction finding.
Oscilloscope bus decoding, RTO2000, bus decoding, I2C Dive into your protocol to check for any problems with your I²C interface.
Rohde & Schwarz Drivers under VEE - Installation and Troubleshooting
20-Dec-2012 | AN-No. 1MA035
Discover some of the key parameters of an oscilloscope and how they impact on the performance in this video series: Part 1: Bandwidth and frequency response R&S®RTO2000 Video, application videos, oscilloscope, troubleshooting, mixed signal oscilloscope R&S Talking about bandwidth Open Lightbox Talking about bandwidth
The R&S®RTO-K92 eMMC Compliance Test option offers an automated test solution for the electrical interface of an eMMC device according to the JEDEC specification, revision 5.1. Oscilloscope Application Videos, Application Video, Application Videos, Videos, eMMC Interface Compliance Test Learn how you can use the eMMC compliance test of R&S for automated testings of electrical interfaces!
RTO2000, debugging, EMI When debugging EMI problems in electronic circuits, development engineers face the challenging problem of quickly and accurately identifying and eliminating the sources of unwanted emissions. Many problems can be eliminated during development by using oscilloscopes for EMI debugging.
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
Measuring the power supply noise rejection (PSNR) requires accurate generation and leveling of artificial, sinusoidal disturbances and measurement of resulting phase-noise and jitter impairments.
30-Sep-2020
Oscilloscope bus triggering, RTO2000, bus triggering, history mode, break condition Use the hardware trigger to isolate break conditions. Break conditions can be corellated with their root cause one by one using the History Mode.
RTO2000, waveform display, R&S®SmartGrid, complex measurements Use the R&S®SmartGrid function to configure the display. For complex measurement tasks where several screen displays are helpful, you can superposition windows in multiple tabs. All measurement diagrams have labeled scales so you can immediately read important signal characteristics.
RTO2000, user interface, toolbar, display, cockpit The advanced user interface enables clear orientation thanks to colour coding, as well as having a high-resolution capacitive touchscreen with gesture support. The toolbar at the top of the screen provides access to frequently used functions such as measurements, zoom and FFT.
Oscilloscope bus debugging, RTO2000, bus debugging, UART, RS232, RS485 Let your Oscilloscope decode your UART/RS232/RS485 interfaces for you! So you can quickly understand the data and correlate the data content with the electrical signal.