Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
3270 Results
It use the integrated 16 GHz differential pulse source and offers Wizard support for calibration and measurement. This additional option makes the R&S RTO and RTP oscilloscope to powerful multi-functional debug tools. Video, TDR/TDT, oscilloscopes, RTO, RTP Evaluate impedance and transmission loss of your signal traces with the RTO or RTP oscilloscope's TDR/TDT Analysis option.
This video demonstrates the speed, safety and privacy features of the Rohde & Schwarz Quick Personnel Security Scanner and explains the millimeter wave radio technology it uses. QPS demo video Enhanced Technology Solutions for Evolving Security Challenges
R&S QuickStep Test Executive Software - Product Brochure
R&S®TS8997 Regulatory Test System for Wireless Devices, Regulatory test systems for wireless devices to measure wideband transmission systems in 2.4 GHz and 5 GHz bands along with ETSI EN 300328 and ETSI EN 301893
R&S TS-PIO2 Analog and Digital I/O Module - Product Brochure
The R&S®ZN-Z86 and R&S®ZN-Z86X switch matrices are designed and optimized for use with the R&S®ZNA, R&S®ZNB and R&S®ZNBT vector network analyzers. They offer a comprehensive, cost-effective total solution for simple to complex measurement tasks on multiport or multiple devices.
Simple and easy setup to perform precise pulse measurement for maintenance and troubleshooting of radar system by using R&S®Spectrum Rider FPH and with Rohde & Schwarz wideband power sensor. Simple and easy setup to perform precise pulse measurement for maintenance and troubleshooting of radar system by using R&S®Spectrum Rider FPH and with Rohde & Schwarz wideband power sensor.
Expert Talk Oscilloscope: I²C bus decoding How to identify and trace down errors in I²C interfaces using the Hardware Trigger together with History Mode. How to identify and trace down errors in I²C interfaces using the Hardware Trigger together with History Mode.
This video demonstrates the ease of radome and bumper analysis using the R&S®QAR.
Read more about measurement results for one-way latency (OWL) and round trip time (RTT) in a commercially deployed public 5G non-standalone network.
MXO 4 - See the difference This video shows you how you can better place and stabilize your probes using the the Rohde & Schwarz 2D positioner for passive probes and the 3D positioner for other probes. This video shows you how you can better place and stabilize your probes using the the Rohde & Schwarz 2D positioner for passive probes and the 3D positioner for other probes.
The R&S®HA-Z24E External Preamplifier Manual describes how to set up the preamplifier, how to read out the s-parameters using the provided software, and how to insert the preampifier in a measurement setup. It also includes safety information and a performance test to check the preamplifier's performance.
Automotive OABR Ethernet is now standardized as 100BASE-T1 in the IEEE. 100BASE-T1 is currently used in most new car developments as the new automotive standard. Analyzing bus communication, by connecting the bus to an oscilloscope measuring the bus voltage levels, is what developers use in traditional networks like CAN or LIN.
This application note describes remote operation or monitoring of the R&S® RTO digital oscilloscope through a standard web browser. The common cross-platform technology Virtual Network Computing (VNC) is used as a server on the instrument.
27-Jul-2010 | AN-No. 1ER01
Setting up complex real-time trigger conditions using the R&S®RTE and R&S®RTO oscilloscopes increases the test coverage and robustness of converter and inverter systems.
10-Aug-2020
Load pull is a powerful method to characterize RF power amplifiers and enablse model extraction and validation and performance, ruggedness and efficiency testing.
02-Sep-2020
White paper: Characterizing parasitic components in power converters
Learn about the different mobile network testing phases for private networks while verifying and monitoring quality and performance.
Simple Network Management Protocol - Remote Controlling for Monitoring Devices
16-Mar-2007 | AN-No. 7BM65
This application note introduces the reader to the SpaceX Hyperloop Pod Competition project and their special demands for the electrical drive train.
31-Mar-2021 | AN-No. GFM360
Assistance at special occasions such as major events
Automatic workflows for a continuous 24/7 remote spectrum monitoring. More information.
Automatic workflows for a continuous 24/7 remote spectrum monitoring. More information.
MIPI D-PHY is a low-power, cost-effective physical layer interface, essential in mobile devices and advanced technology systems. It's a high-speed, source-synchronous interface used in smartphone cameras, smartwatch displays, drones, in-car entertainment, automobile cameras, and radar sensors. This application note explores MIPI D-PHY's features, functionality, and testing practices for device compliance, addressing common issues. It highlights Rohde & Schwarz's equipment for ensuring compatibility and solving issues with MIPI D-PHY, aligned with MIPI D-PHY specification version 2.5.Developed by the MIPI Alliance, D-PHY connects cameras and displays to a host processor via CSI-2 or DSI protocols. It features a master-slave, asymmetrical design for reduced link complexity. Key aspects include a unidirectional clock, optional data signal directions, different data rates for half-duplex operation, point-to-point communication, and high-speed (HS) and low-power (LP) modes for data transfer and battery preservation. In HS mode, D-PHY uses differential signaling with specific impedance, while in LP mode, it operates in a single-ended manner with high impedance termination.The application note from Rohde & Schwarz provides insights into characterizing and debugging MIPI D-PHY, offering conformance verification with MIPI Alliance standards and protocol decoding options.
31-Jan-2024 | AN-No. 1SL410
The focus is on understanding as early as possible in the design process performance enhancements through linearization of non-linear devices.
20-Apr-2022 | AN-No. 1SL383
I perform a calibration with remote commands. With the command to start the calibration sweep with a short standard I get this error message. What is the problem?
All the user needs are the logic probes required to start using the 16 digital channels. R&S®MXO 4 SERIES OSCILLOSCOPE, oscilloscope, scope, R&S®MXO 4,digital logic channel Add 16 digital channels to the R&S®MXO 4 and use them simultaneously with all analog channels.
This video presents how to create simple pulse sequences by using repetitions and loops together with pulses with R&S®SMW200A and R&S®Pulse Sequencer software. This video presents how to create simple pulse sequences by using repetitions and loops together with pulses with R&S®SMW200A and R&S®Pulse Sequencer software.
A closer look at phase resolution and practical demonstration using cut outs is included.
R&S®NGA100 power supplies are linear, compact and easy to use. All models have excellent readback accuracy with a low-current range for demanding measurements. Features such as data logging, arbitrary waveforms, built-in statistics and remote sensing make the instruments ideal for various bench applications. Equipped with a number of different remote interfaces, including USB and Ethernet, R&S®NGA100 power supplies are great for automated testing.