Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
133 Results
The test case wizard enables the signal generator to set up all required parameters for conformance testing of 5G NR base stations in no time with just a few clicks.
25-May-2021
The option R&S®EMC32-K84 extends the internal report generator to support the generation of a summary test report over all selected test cases done for a DUT. Additional the report is directly written to Microsoft®Word and thus can be easily combined with customer specific report templates.This Application Note shows all necessary steps on an example report to configure and execute the report generation.
23-Apr-2015 | AN-No. 1SP09
Stable operation in all circumstances is essential for power converters. Different working conditions, such as load steps, startup/shutdown sequences and input voltage variation, apply to most converter types. In addition to the standard feedback control loop, integrated pulse width modulation (PWM) controllers provide extended functions, such as line feed-forward loop control and soft-start control. These extended control functions improve regulation for specific conditions. Such complex regulation systems require smart methods to ensure proper operation of the converter in all modes. For this task, extensive expertise and the right measurement tools are essential for identifying and locating unexpected events in the system.
11-Oct-2023
Testing radomes and bumpers in all phases – from design to high-volume production Testing radomes, bumpers, QAR50 Ensure a high level of performance and reduce performance degradation of automotive radar sensors caused by radomes and bumpers with the R&S®QAR50.
21-Apr-2022
Complex production workflows in several broadcast, post production or presentation environments not only need a solid storage architecture, but also intelligent project sharing since several teams require access to all data.
18-Nov-2014
This application note describes methods using an R&S®ZVA network analyzer, one or two R&S®SMB100A signal generators and an R&S®FSW signal analyzer to accurately measure all the key parameters of frequency converters with embedded local oscillator. A commercial satellite up-converter is used as a device under test example.
30-Apr-2015 | AN-No. 1MA224
This application note shows all necessary settings for performing Dual Receiver Measurement using the R&S®EMC32-K27 option via R&S® EMC32 Measurement Software.
28-Sep-2017 | AN-No. 1SP20
This application note explains step by step all necessary settings for transmitting parameters of the disturbance signal from an EMS test to a dAV Camera System via serial port or LAN interface. The dAV Camera System overlays these parameters onto the camera signal.
10-Dec-2019
Simulation can be a big time-saver when designing EMI filters for DC/DC converters. Power supply control chip vendors offer various filter design tools that provide reasonable design choices for filter simulation before any hardware prototype is available. However, simulated results can differ significantly for different tools if simulated models are not accurate or do not cover all the relevant components. Performing a hardware measurement to evaluate the effectiveness of a simulated EMI filter is therefore indispensable.
21-Sep-2021
This application note describes how to characterize RMS jitter with the R&S FSUP signal source analyzer. The instrument can distinguish random jitter and periodic jitter easily and measure all parameters of interest. New feature: A filter function can be used for jitter calculation to simulate the frequency response of the PLL in the DUT.
05-Apr-2011 | AN-No. 1EF71
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many listeners. A single instrument, the R&S®ETL TV analyzer, performs all required DAB transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.
24-Jul-2013 | AN-No. 7BM104
Power converters with a full-bridge topology are frequently used in telecommunications and servers that need to be compact, efficient and cost sensitive, making them more complex. Switching patterns for all the main primary switches including synchronous rectifier switches need to be validated after the first protype is built. This complex validation requires proper measurement of switching patterns to prevent catastrophic switching patterns. Expertise and the right measurement tools are essential when identifying unexpected events in the converter switching process.
17-Jan-2024
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
The option R&S®EMC32-K23 extends the emission measurement of the EMI Auto Test (R&S®EMC32-K10) with 3D measurement capabilities.This extension is useful to display the 3D radiation pattern of each frequency.This Application Notes shows all necessary settings for 3D measurement.
26-Aug-2014 | AN-No. 1SP08
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers. A single instrument, the R&S®ETL TV analyzer, performs all required ATSC transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commis-sioning and preventive maintenance.
13-May-2013 | AN-No. 7BM102
Signaling checks, DSMCC object carousel analysis and fault localization all in one instrument: R&S®DVMS, R&S®DVM or R&S®ETL
28-Dec-2012
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers. A single instrument, the R&S®ETL TV analyzer, performs all required DVB-T / DVB-H transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.
13-May-2013 | AN-No. 7BM101
This Application Note gives an introduction to measurements of WiMAX signals according to standards 80216-2004 and 802.16e-2005. It describes all kind of signal generation from simple signals to multiple-zone signals, also under multipath environment (fading), and covers all signal measurements from power and spectrum analysis, crest factor and CCDF measurement down to bit pattern analysis and modulation measurements.Please see also 1MA96 for General information about the WiMAX standard and 1EF57 for an introduction to the WiMAX standard.
10-Jul-2006 | AN-No. 1MA97
radiated conformance testing according to TS 38.141-2, Rel. 16
3GPP defines the Radio Frequency (RF) conformance test methods and requirements for 5G NR Base Stations (BS) in the technical specifications TS 38.141. This application note describes all mandatory radiated RF transmitter tests (TS 38.141-2, chapter 6), according to Release 16.Furthermore, this document provides a brief introduction about the different R&S OTA antenna test solutions and how they are applicable for base station conformance testing. Rohde & Schwarz offers solutions for any test case that is mentioned in this application note.
20-Dec-2019 | AN-No. GFM324
DC power supplies from Rohde & Schwarz can be connected and configured for synchronized on/off switching of all channels across multiple power supplies in intricate and complex systems.
28-Apr-2023
Simultaneously measure various current levels from μA to A in all phases of IoT device activity – from sleep to receive and transmit mode
01-Oct-2019
3GPP TS25.141 defines conformance tests for W-CDMA base stations (including HSPA+ features). This application note describes how all required receiver (Rx) tests (TS25.141 Chapter 7) can be performed easily and quickly by using vector signal generators and CW sources from Rohde & Schwarz. One test additionally requires a spectrum analyzer from Rohde & Schwarz.Example illustrates manual operation. A free software program enables and demonstrates remote operation. The W-CDMA base station transmitter (Tx) tests (TS25.141 Chapter 6) are described in Application Note 1MA67.
21-Oct-2014 | AN-No. 1MA114
Sporadic events and errors may occur when developing new measurement instruments and need to be taken into account in all design stages and analyses. The Rohde & Schwarz power supplies can precisely capture such sporadic events and errors.
02-May-2023
The terrestrial television standard DVB T2 is gaining in significance as a result of the growing scarcity of available frequencies. New systems are being tested in many countries around the world. Other countries have already completed the introductory phase for DVB T2. Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers or even disrupt adjacent channels.A single instrument, the R&S®ETL TV analyzer, performs all required DVB-T2 transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.The measurements described here satisfy many country-specific and customer-specific test specifications. Users need only set the limit values accordingly.
24-Jul-2014 | AN-No. 7BM106
The Application Note summarises all measurements for WLAN test, according to the IEEE Standards 802.11a, b and g. For each measurement, an instrument list, test setups, test method, comments, typical results and implementation hints are included. The enclosed free of charge software provides all IEEE 488 bus sequences ready to run or copy into your own test environment.
28-Jul-2004 | AN-No. 1MA69
conducted conformance testing according to TS 38.141-1, Rel. 16
3GPP defines the Radio Frequency (RF) conformance test methods and requirements for 5G NR Base Stations (BS) in the technical specifications TS 38.141. This application note describes how all mandatory RF performance tests (TS 38.141-1, chapter 8), according to Release 16, can be performed quickly and conveniently with signal generators from Rohde & Schwarz by either choosing manual operation or a remote control approach.In Addition, a new Python software library comes with this application note to enable the remote control approach of base station testing. This example requires the RsInstrument module which can be found on pypi.org or installed via 'pip' and is provided as is.
24-Oct-2019 | AN-No. GFM315
3GPP TS36.141 defines conformance tests for EUTRA base stations (eNodeB). Release 14 (LTEAdvanced Pro) added several tests, such as those for enhanced Licensed Assisted Access (eLAA).This application note describes how all required performance tests (TS36.141 Chapter 8) can be performed quickly and easily by using vector signal generators from Rohde & Schwarz.Examples illustrate the manual operation. A free software program enables and demonstrates remote operation.The LTE base station transmitter (Tx) tests (TS36.141 Chapter 6) are described in Application Note 1MA154.The LTE base station receiver (Rx) tests (TS36.141 Chapter 7) are described in Application Note 1MA195.
11-May-2016 | AN-No. 1MA162
Radar technology is essential for state-of-the art and future vehicles on the path to full autonomous driving. Radar sensors deliver critical information about the surrounding traffic environment or monitor the interior of the vehicle. As safety-relevant parts, radar sensors must adhere to specifications and regulations.
12-Dec-2022
The R&S®CMW Wideband Radio Communication Tester offers an elaborate parametric test concept, including all RF test cases up to Bluetooth®5, that makes this flexible test platform ideal for designing and verifying Bluetooth® Low Energy (LE) circuitsand modules.
27-Jan-2017
Most of today's electronic devices draw non‑sinusoidal current. This gives rise to harmonic currents injected back into the public supply system. These need to be checked on all devices with the CE marking.
12-Oct-2018