Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1113 Results
Power converters with a full-bridge topology are frequently used in telecommunications and servers that need to be compact, efficient and cost sensitive, making them more complex. Switching patterns for all the main primary switches including synchronous rectifier switches need to be validated after the first protype is built. This complex validation requires proper measurement of switching patterns to prevent catastrophic switching patterns. Expertise and the right measurement tools are essential when identifying unexpected events in the converter switching process.
17-Jan-2024
A whole series of measurements has to be carried out for drafting an acceptance test report for a VHF sound broadcasting transmitter in compliance with ARD Specifications 5/3.1 (= TL 5820-3018 of the Deutsche Bundespost). As in most cases parameters like transmitter output power, frequency stability, spurious modulation, etc. have to be measured in the two stereo channels of the transmitter separately and at different modulation frequencies and frequency deviation, manual-controlled measurements are very time-consuming. In addition, a great variety of test equipment eg AF generator, stereodecoder, level meter, etc. is required for the measurements. FMAB with option FMA-B4 (AM/FM Calibrator / AF Generator) is ideally suitable for these measurements on VHF sound broadcasting receivers. The internal AF generator provides the signals required for the left and the right stereo channel. The MPX signal from the VHF transmitter is decoded by the built-in stereodecoder. As a result many of the tests and measurements required for the acceptance of VHF sound broadcasting receivers can be carried out without any additional test equipment being required. To give an example, a test program running under the graphics user interface Microsoft Windows has been developed for carrying out automatic power and modulation measurements via a PC.
04-Jun-1998 | AN-No. 1EF09
Vector Network Analyzers of t ZNA and ZNB family are able to measure magnitude and phase of complex S-parameters of a device under test (DUT) in the frequency domain. By means of the inverse Fourier transform the measurement results can be transformed to the time domain. Thus, the impulse or step response of the DUT is obtained, which gives an especially clear form of representation of its characteristics. For instance, faults in cables can thus be directly localized. Moreover, special time domain filters, so-called gates, are used to suppress unwanted signal components such as multireflections. The measured data "gated" in the time domain are then transformed back to the frequency domain and an Sparameter representation without the unwanted signal components is obtained as a function of frequency. As usual, other complex or scalar parameters such as impedance or attenuation can then be calculated and displayed.
30-Jul-2020 | AN-No. 1EP83
R&S®Series4200 detection of simultaneous transmissions (DSiT) option for air traffic control
21-Aug-2014
Using option ZVR-B4 (Frequency Converting Measurements), a ZVR Vector Network Analyzer can be used for measurements on frequency converting devices such as mixers and amplifiers. Using the ZVR's ARBITRARY mode, the source and receiver frequency ranges of the ZVR's generator and receiver, plus for two external signal generators, can be defined independently. As a result, mixer and intermodulation products such as conversion loss or sampling mixers, can all be measured. Used together with option ZVR-B6 (Reference Channel Ports), group delay measurements can also be made on frequency converting devices.
19-Jan-1999 | AN-No. 1EZ47
This application note describes how the most important fading tests for mobile phonesin all GSM frequency bands can be carried out cost-effectively using a combination of a CRTP/C02 Radiocommunication Tester and SMIQ Signal Generator.
23-May-2000 | AN-No. 1MA19
The R&S®CMP200 radio communication tester together with the R&S®CM-Z300A time of flight kit provides an accurate setup for time of flight measurements – in validation, calibration and certification.
27-Jul-2022
This Application Note provides an overview of the Bit Error Rate (BER) test capabilities of the Universal Radiocommunication Tester CMU300 on GSM / EDGE Base Stations. It includes information about measurement principles, the supported test environment and channels, CMU settings, operation, and ordering information.
15-Jan-2002 | AN-No. 1CM32
This application note describes Methods of Implementation (MOI) for precise, fast, and error-free compliance testing of USB Type-C to Type-C cable assemblies supporting USB4 Gen3, USB4 Gen2, USB 3.2 Gen2, USB3.2 Gen1, and USB2.0.
30-Nov-2023 | AN-No. 1SL405
The Rohde & Schwarz R&S®CMU200 can be configured to perform packet data testing in a Mobile IP or Simple IP environment. This application note is intended as a guide to configuring the necessary Mobile IP or Simple IP network elements and R&S®CMU200 instrument for CDMA2000®1xEV-DO.
04-May-2007 | AN-No. 1CM64
Active, high-impedance probes can be connected to spectrum analyzers, providing a practical and highly precise measurement solution to overcome an otherwise cumbersome RF testing issue. This application note provides information on how to use oscilloscope probes in RF measurements using spectrum analyzers.
04-Jul-2023 | AN-No. 1EF116
The FLO in MediaFLO stands for 'forward link only'. MediaFLO technology covers transmission of files and multimedia content to handheld devices. The FLO device minimum performance specification (MPS) was created to ensure that FLO receivers can receive a FLO service that fulfils the compatibility guidelines of the FLO air interface specification. This Application Note shows how the Broadcast Test System R&S SFU from Rohde & Schwarz can be used to generate all test scenarios required by the minimum performance specification.
31-Aug-2006 | AN-No. 7BM62
This Application Note describes the internal transfer of ZVR measurement data in Excel, carried out on the PC option of the ZVR, and the evaluation of the data in Excel tables. To start the data transfers, macros are implemented under Excel.
28-Jul-1998 | AN-No. 1EZ39
TS-EMF2 TS-EMF TRD Conversion TRD Conversion TS-EMF2 TS-EMF TRD Conversion Related products
25-Jan-2007 | AN-No. TS-EMF2
There are proposals for broadband measurements on hearing aids, for example the proposed standard ANSI S3.42. Such measurements are intended to simulate more accurately the behaviour of hearing aids under normal hearing conditions also in the presence of ambient noise. Audio Analyzer UPD fitted with High-Speed Option UPD-B3 makes it possible already now to generate the proposed test signal and to perform all the related measurements including coherence and transfer functions. These measurements may become more and more important in the future but have scarcely been performed up to now as they require highly complex test equipment. Audio Analyzer UPD enables the user to measure to tomorrow’s standards even today.
04-Jun-1998 | AN-No. 1GA34
This application note provides information how to perform noise figure measurements under pulsed or bursted conditions with spectrum analyzers and noise sources, and introduce the capabilities of the Rohde & Schwarz FSW signal and spectrum analyzer to perform this measurement.
28-Jun-2018 | AN-No. 1EF103
Application Note 1MA68 has been replaced by .
10-Dec-2008 | AN-No. 1MA68
O-RAN radio units (O-RU) contribute significantly to the high power consumption of 5G networks. Making O-RUs energy efficient without sacrificing O-RAN innovations is a top priority.
19-Mar-2024
Introduction to the fundamentals of programming the R&S Smart Instruments Family 300 in different developement environments.
25-Jun-2007 | AN-No. 1MA73
Deembedding, often a necessary and complex task, is made easier with an integrated hardware and software solution.
25-Sep-2018
The R&S®SMF100A microwave signal generator offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace signal generators, e.g. from other manufacturers, with the R&S®SMF100A without having to change the remote control code. This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
11-Oct-2016 | AN-No. 1GP92
Some of the new Rohde & Schwarz instruments, such as the R&S®OSP and R&S®FSC, only have a LAN interface. To be able to operate these instruments in a purely GPIB system, a converter must be connected between the instrument and the GPIB. Rohde & Schwarz now offers such a GPIB to LAN converter.
03-Aug-2010 | AN-No. 1SP30
The R&S®QPS millimeterwave security scanner delivers the most accurate measurement results in 1.5 to 2.5 s. The instantaneous scan requires only 64 ms, or five times faster than the blink of an eye, virtually eliminating the ambiguous readings that occur due to accidental movement with the longer scan time of other imaging technology.
22-Jan-2019
The R&S®NRP2 power meter offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace power meters, e.g. from other manufacturers, with the R&S®NRP2 power meter without having to change the remote control code. This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
28-Feb-2012 | AN-No. 1GP83
The new buffer analysis feature was introduced with firmware version 2.80 for the R&S DVM family. This application note describes this feature and explains how it represents a valuable asset to your daily business operations This application note first provides background information and then explains how monitoring and measurement have been implemented in the R&S DVM family.
23-Mar-2006 | AN-No. 7BM53
Trace minimum hold function with the R&S®MNT100, R&S®PR200, R&S®PR100 and R&S®DDF007
15-Jul-2019
For A/V devices such as smartphones, tablet PCs, Blu-ray players, set-top boxes and TV sets, the perceived video quality must satisfy very high standards. A/V devices need to hold their own in three main areas:ı Stability (environmental influences, response to source signal disturbances, etc.)ı Performance (switching times, delays)ı Compliance with standards (input and output formats)Any deviations from the expected video and audio output can be automatically and precisely detected with R&S A/V distortion analysis on all common analog and digital interfaces such as HDMI™ and MHL™.This document examines the relevant setups and configurations.
15-Oct-2014 | AN-No. 7BM87
Despite the now standard digital distribution of video signals, analog video signals are still an integral part of AV terminals in the home. This application note covers the fundamentals of analog component signals and shows how the signal quality can be measured with the measuring equipment from Rohde & Schwarz.
28-May-2015 | AN-No. 7MH107
This application note provides information about the spurious emission measurement on 3 GPP base station transmitters. The basic requirements and the limiting factors of a spectrum analyzer are explained in detail. Dynamic range calculations with measurement examples show the practical realisation of spurious emission measurements.
10-Jan-2002 | AN-No. 1EF45
Particle acceleration requires cavity resonators that are driven with high RF powers at defined frequencies. Rohde & Schwarz offers RF solid-state amplifiers for frequencies ranging from 9 kHz to 6 GHz, delivering CW power up to 80 kW.
27-Apr-2016