783 Results
I wrote a remote control script for my HMC series instrument which should get the log data I wrote to an external USB stick before. Using "EXT" will throw the error "File name not found". When I take a look at the USB stick on my PC, I can see that it definitely wrote the file to DRIVE:\Data\LOGFILE.CSV.
I have a R&S Laboratory Power Supply and could find not find a way to make it switch on the output automatically after mains comes up. How can this be done?
Serial and Parallel Channel operation of Power Supply Units (PSUs) in general
Development Hints and Best Practices for Using Instrument Drivers
01-Jan-2013 | AN-No. 1MA153
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
How can a number of files from the sw 'InstrumentView' be converted to CSV format? How can a number of files from the sw 'InstrumentView' be converted to CSV format? Related Products
Where can I download the waveform and stream libraries for the R&S®SMCV100B? Where can I download the waveform and stream libraries for the R&S®SMCV100B? Related Products
Single Pulse via the HMF2525/HMF2550 Signal Generator by using the enter key as a trigger source Single Pulse via the HMF2525/HMF2550 Signal Generator by using the enter key as a trigger source Related Products
What is wrong with my Script?
RTE/RTO/RTP-B6: Output of a single waveform in single mode with remote commands RTE/RTO/RTP-B6 single waveform RTE/RTO/RTP-B6: Output of a single waveform in single mode with remote commands RTE/RTO/RTP-B6 single waveform Related Products
600 ms RF Pulse/Burst Measurement with Accuracy of less than 1 ms?
How to generate separate graphics for the horizontal and vertical result using EMC32-EB
How to automatically transfer IQ-data from FSVR Spectrum Analyzer to VSE software
FSH: How to perform a signal strength measurement showing the results on the outdoor map
Converting the real and imaginary numbers to magnitude in dB and phase in degrees.
Calibrating a clamp and creating a transducer table using the R&S ELEKTRA signal path calibration utility
How can I use the 2nd function to measure DCI and DCV in one setup via remote control?
How to start the internal alignment on the FSL and get the results via external commands.
Add Limit Line to existing EMC32 Test to create a new list of critical frequencies
What is the correct pin layout of the DC inputs on the network analyzer's rear panel?
ENV216 - how to use with DC-DUTs e.g. @ 12 V or 24 V
How can I copy the screen shots from the internal memory to an USB stick?
Active cal kit or cal unit does not contain all standards needed for selected cal procedure.
Copy the entire database from old version of ELEKTRA to the latest version of ELEKTRA
How can I export the traces of a specific channel into one file, i.e. CSV?
What is the calculation base for the sample rate on my R&S RTA / RTM series scope when using FFT?
How can offline logs analyzed with CMW Mars message viewer tool for existing test runs that are saved on the CMW.
I am using the ultra segmentation mode to minimize the blind time. But this is not indicated. Is there a way to calculate it?
RTE/RTO/RTP: Measurement of the level at a designated frequency in FFT with remote commands.
I want to measure the S11 of an antenna over a bigger frequency span as the transmission area is. Can I check for a limit only over a part of the span?