154 Results
Save/recall files: own folder in 'Look In'
License Keycode for VNAMUC is not accepted
The MINUS key on the keypad does not work.
How can I start a SSST calibration?
I want to control my Analyzer using Remote Desktop from my PC. My Analyzer does not react.
Calibration of two channels simultaneously with remote commands
I have an existing limit line. Is it possible to apply a vertical offset?
Is there a way to query the data of all traces at once?
TRL calibration - middle of line or end of line
Export complex data of a trace with mathematics and time gating.
Store several diagrams in one file and each diagram on its own page
VNA - do I really need a sliding match for calibration?
Calibrating a vector network analyzer (VNA) with different connectors on each port
Rohde & Schwarz user manual for the external RFFE/GPIO interface R&S®ZN-Z15
Active cal kit or cal unit does not contain all standards needed for selected cal procedure.
I have several traces with markers in one channel. When I query the result of marker 1 I always get the response of trace 1. How can I get the result of marker 1 for trace 2?
I query the values of a trace using scpi commands. But I get the y-values only. Is there a possibility to get the y-values also (frequency)?
I have a file on my device. How can I get it in a simple way to my PC?
How do I calculate these frequency points when I have a logarithmic sweep and know the center frequency, the span and the number of sweep points?
This application note describes how to configure a Rohde & Schwarz Network Analyzer to make spectral measurements directly on a device under test.
16-Mar-2012 | AN-No. 1EZ62
Rohde & Schwarz Technical Information for the R&S ZV-Z129/-Z135/-Z170 calibration kits.
Rohde & Schwarz Technical Information for the R&S ZN-Z170/-Z135/-Z129/-Z129E calibration kits.
This paper shows how to perform a n-port multi-port calibration by using calibration unit with a lower number of ports than available of the vector network analyzer.
06-Feb-2013 | AN-No. 1EZ70
This document describes how a Windows®-based R&S® T&M instrument is remotely operated by an Android™ tablet as if working on it locally.
22-Aug-2013 | AN-No. 1MA236
This application note describes Methods of Implementation (MOI) for precise, fast, and error-free compliance testing of USB Type-C to legacy cable assemblies supporting USB3.1 Gen2, USB3.1 Gen1, and USB2.0. Based on 5 Gbps signaling per lane with vector network analyzers from Rohde & Schwarz.
18-Jan-2024 | AN-No. 1SL406
This application note describes Methods of Implementation (MOI) for precise, fast, and error-free compliance testing of USB 3.2 Legacy Cable Testing for USB Type A, Type B, and Micro family connector types. Based on 5 Gbps and 10 Gbps signaling per lane with vector network analyzers from Rohde & Schwarz.
09-Nov-2023 | AN-No. 1SL408
This application note describes Methods of Implementation (MOI) for precise, fast, and error-free compliance testing of USB Type-C to Type-C cable assemblies supporting USB4 Gen3, USB4 Gen2, USB 3.2 Gen2, USB3.2 Gen1, and USB2.0.
30-Nov-2023 | AN-No. 1SL405
25-Nov-2021
Rohde & Schwarz empowers Allion labs to offer Automotive Ethernet testing according to the OPEN Alliance TC9Rohde & Schwarz Taiwan, subsidiary of the global technology group, and Allion Labs, a leading professional services group providing certification testing services, have jointly developed test capabilities for Automotive Ethernet Shielded & Unshielded Twisted Pair (UTP & STP) in compliance with the OPEN Alliance TC9 standards.
This document describes how a Windows®-based R&S® T&M instrument is remotely operated by an Apple iPad as if working on it locally.
28-Mar-2013 | AN-No. 1MA216