726 Results
RTP oscilloscopes can trigger on signals as small as 1/1000th of a vertical division thanks to digital triggering and adjustable hysteresis. 3 12 RTP, oscilloscope, scope, MSO, update rate, trigger, digital trigger RTP- see the difference. Trigger with highest sensitivity at full bandwidth.
Video, RTB2000, oscilloscope, Easy report creation The R&S®RTB2000 makes sharing your results easy.
Video, RTM3000, Oscilloscope, harmonic analysis The R&S®RTM3000 features analysis of input and output as well as transfer function of switched-mode power supplies.
This application note introduces the reader to the SpaceX Hyperloop Pod Competition project and their special demands for the electrical drive train.
31-Mar-2021 | AN-No. GFM360
This application note provides an introduction to the DDR memory technology and explains common challenges, related to the specific nature of DDR data, command and control buses.
30-Oct-2020 | AN-No. GFM340
The R&S®RTE and R&S®RTO oscilloscopes can measure currents down to 100 uA using their low noise and high-sensitivity current probe. Video, RTO2000, Oscilloscope, Measurement of very small currents The R&S®RTE and R&S®RTO oscilloscopes can measure currents down to 100 uA using their low noise and high-sensitivity current probe.
Thanks to 18-bit resolution, it is possible to measure active mode and sleep mode currents at the same time and correlate this to other signals captured with the oscilloscope. power consumption measurements, IoT, R&S RT-ZVC, multi-channel, probe, 18-bit, resolution This video demonstrates how to perform power consumption measurements on IoT devices with the R&S RT-ZVC multi-channel power probe.
Video, RTA4000, Oscilloscope, Vertical Zoom The R&S®RTA4000 features a vertical zoom.
Video, RTA4000, Oscilloscope, ADC, 10-bit, 8-bit The R&S®RTA4000 features a customized Rohde & Schwarz engineered 10-bit A/D converter.
Additional tools such as the spectrogram illustrate the signal characteristic over time. 8 12 RTP, oscilloscope, scope, MSO, spectrum analysis, spectrogram, RF signal, wide-band RTP- see the difference. Use the accuracy of the RTP for the analysis of wide band RF signals.
At any point in time, acquisition can be stopped and any waveform in the history buffer can be analyzed using the full oscilloscope functionality. history mode, analyze, recent, acquisitions, automatically, stores, 5000, waveforms, buffer This video demonstrates how to use the history mode to analyze recent acquisitions.
It catches infrequent events faster, reacts more responsively on setup changes and collects data for statistical analysis more rapidly. 2 12 RTP, oscilloscope, scope, MSO, update rate, display rate, acquisition rate See the difference. Test and debug more quickly with the RTP oscillscope offering the industries fastest update rate.
Video, Oscilloscope, Debugging high-speed designs We discuss key test challenges and present methods and tools for debugging digital designs including high-speed interfaces with a data rate of up to 5 Gbps.
Learn to use it most easily. 6 12 RTP, oscilloscope, scope, MSO, automated measurements, measurements, time, voltage, jitter, eye RTP - see the difference. Learn how to perform faster and more in-depth measurements on analog, RF or digital signals.
Affordable digital oscilloscopes with outstanding features. Wowee, are we right? The R&S®ESSENTIALS digital oscilloscopes . Wowee, are we right? With outstanding features like super-fast update rate, low blind time and deep memory , our inexpensive oscilloscope range does exactly what it should, so you can do exactly what you should . Shine. So, how does that make you feel? Curious?
Video, RTO2000, Oscilloscope, Industry-leading mask test Defining masks is easy and flexible with the R&S®RTO.
Based on the new high-performance R&S®SMW200A vector signal generator and the R&S®RTO digital oscilloscope, the solution provides MIMO signal generation and realtime channel emulation (up to 4x4 or 8x2) as well as synchronous analysis of multiple TX antenna signals.
This is 10 times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates. Video, RTB2000, oscilloscope, 10 Msample memory The R&S®RTB2000 offers a class-leading memory depth:10 Msample per channel are available, even 20 Msample in interleaved mode.
R&S®MXO 5 SERIES OSCILLOSCOPE Use the R&S®MXO 5 Series oscilloscopes with the industry’s largest offset for your power integrity measurements.
Video, RTB2000, oscilloscope, 10 bit ADC The R&S®RTB2000 features a customized Rohde & Schwarz engineered 10-bit A/D converter that delivers a fourfold improvement compared to conventional 8-bit A/D converters.
14-Jul-2022
Granite River Labs and Rohde & Schwarz extend partnership to broaden European test lab’s compliance testing capabilitiesHaving recently opened their new state-of-the-art high-speed digital compliance test laboratory in Germany, Granite River Labs (GRL) has now further extended their scope of industry services for a growing European market. By adding the R&S ZNB20 vector network analyzer from Rohde & Schwarz to complement the previously acquired R&S RTP164 high-performance oscilloscope, the GRL test lab is able to offer an even broader range of testing services around established and future high-speed digital technologies like Automotive Ethernet or USB.
Transient Measurements on GSM/PCN Synthesizers
03-Jun-1998 | AN-No. 1EF08
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
Video, RTB2000, oscilloscope, Video FFT Frequency analysis mode R&S®RTB2000 includes frequency analysis as a standard feature. is activated with the push on a button and by just entering center frequency and span.
Video, RTM3000, Oscilloscope, Vertical Zoom Vertical zoom is an easier way to quickly magnify the portion of the signal you want to see, and retain measurement accuracy.
Video, RTM3000, Oscilloscope, Memory Preview The R&S®RTM3000 offers a class-leading memory depth:40 Msample per channel are available, even 80 Msample in interleaved mode.
For most oscilloscopes this creates a problem not being able to trigger on this math signal. The RTP addresses this with an hardware-based math approach in the acquisition path, enabling for the first time triggering on math signals. 10 12 RTP, oscilloscope, scope, MSO, differential, differential signal, common mode, trigger RTP- see the difference.
For this video, we will be using a 2 GHz R&S®RTO oscilloscope, an 8 GHz R&S®ZND two-port VNA as well as the R&S®ScopeSuite automated test software. Webinar, Automotive, Ethernet This webinar will focus on 1000BASE-T1 automotive Ethernet compliance testing based on the Open Alliance (OA) TC8 specification for the physical layer.
It is designed for precise power integrity measurements in combination with the R&S®RTE1000 and R&S®RTO2000 R&S®RTE1000, Application Videos, rto2000 Precise measurements with the R&S®RTE1000 Oscilloscope and the R&S®RT-ZPR20 Power Rail Probe
An LTE-Advanced 2x2 MIMO downlink signal, generated by a small cell, is captured and processed by one R&S®RTO digital oscilloscope. The R&S®FS-K10xPC LTE analysis software enables detailed analysis of the received signal. video, LTE, SMU200A, RTO, FS-K10xPC Rohde & Schwarz at MWC 2013: LTE-Advanced 2x2 MIMO testing in UL and DL