Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
14 Results
Taking the R&S ESR EMI test receiver as an example, this paper looks at a CISPR 16-1-1- compliant test instrument with time domain scanning capabilities. The paper compares the measurement speed and level measurement accuracy of a conventional stepped frequency scan versus an advanced FFT-based time domain scan. It also contains guidance on making optimum use of time domain scans.
29-Jan-2014 | AN-No. 1EE24
The MFIA impedance analyzer – a multipurpose instrument for R&D and quality control – can be used to measure the ESR and ESL of DC-link capacitors over a wide frequency range.
04-Sep-2024
This application note provides a description of the Rohde & Schwarz Click Rate Analyzer software.In conjunction with the R&S®ESR EMI Test Receiver 4-channel operation is applicable. With R&S®ESU and R&S®ESCI EMI Test Receivers the Click Rate Analyzer software is limited to one channel. This software performs click rate analysis in accordance with CISPR 16-1-1 and CISPR 14-1 / EN 55014-1. It features realtime graphic display of the maximum peak and quasi-peak values. After the measurement, a test report can be displayed and printed.
15-Jan-2015 | AN-No. 1EE25
The LCR meters R&S®LCX100 and R&S®LCX200 precisely measure the complex impedance and the resulting components values over a wide frequency range. Dynamic impedance measurements allow to perform these measurements while sweeping the test signal frequency or other parameters like test signal level and DC bias. This application note provides a PC-based software tool for comfortably setting the sweeps and displaying the results in numerous charts.
14-Mar-2022 | AN-No. 1GP132
Software tools allow to make the control of T&M instruments more convenient. The adoption of the following tools for Windows®-based T&M instruments is described: ● Synergy:One mouse and one keyboard control a group of T&M instruments ● CamStudio:Video clips of the display of a T&M instrumentare recorded during operation
13-Jun-2013 | AN-No. 1MA218
This document describes how a Windows®-based R&S® T&M instrument is remotely operated by an Apple iPad as if working on it locally. Step-by-step procedures are provided for setting up and configuring the T&M instrument and the iPad. On the iPad, a special App implements the Windows® 'Remote Desktop' functionality. T&M instrument and iPad are connected via WLAN (also denoted as Wi-Fi network).
28-Mar-2013 | AN-No. 1MA216
This application note shows how to configure, calibrate and perform conducted EMS (Electro Magnetic Susceptibility) measurements according to IEC / EN 61000-4-6 and EMI (Electro Magnetic Interference) measurements according to CISPR 16-2-1 with the R&S®EMC32 software tool.
19-Jul-2013 | AN-No. 1MA212
This document describes how a Windows®-based R&S® T&M instrument is remotely operated by an Android™ tablet as if working on it locally. Step-by-step procedures are provided for setting up and configuring the T&M instrument and the tablet. On the tablet, a special App implements the Windows® 'Remote Desktop' functionality. T&M instrument and tablet are connected via WLAN (also called Wi-Fi network).
22-Aug-2013 | AN-No. 1MA236
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
This application note shows all necessary settings for performing Dual Receiver Measurement using the R&S®EMC32-K27 option via R&S® EMC32 Measurement Software.
28-Sep-2017 | AN-No. 1SP20
R&S®VISA is a standardized software library that allows fast communications over diverse interfaces with a wide variety of T&M instruments that are detected on the network from PC applications. R&S®VISA also includes a trace tool that simultaneously monitors communications between multiple applications and T&M instruments, and permits targeted analysis with the aid of efficient filters.
26-May-2020 | AN-No. 1DC02
Rohde & Schwarz recognizes the potential risk of computer virus infection when con-necting Windows®-based test instrumenta-tion to other computers via local area net-works (LANs), or using removable storage devices.This white paper introduces measures to minimize malware threats and discusses ways to mitigate risks while insuring that instrument performance is not compro-mised.The paper discusses the use of anti-virus software. It also outlines how to keep the Windows® 7 operating system properly updated through regular installation of OS patches.
27-Jan-2015 | AN-No. 1DC01
Versatile Software Tool for Rohde & Schwarz Instruments
RSCommander is a versatile software tool for a wide range of Rohde & Schwarz spectrum-, network analyzers, signal generators and oscilloscopes. It allows for automatic instrument discovery, making screenshots, reading traces, file transfer and simple script creation.
24-Dec-2017 | AN-No. 1MA074
Rohde & Schwarz recognizes the potential risk of computer virus infection when connecting Windows®-based test instrumentation to other computers via local area networks (LANs), or using removable storage devices. This white paper introduces measures to minimize malware threats and discusses ways to mitigate risks while insuring that instrument performance is not compromised. The paper discusses the use of anti-virus software, with recommended configuration settings. It also outlines how to keep the Windows® XP operating system properly updated through regular installation of OS patches.
04-Oct-2012 | AN-No. 1EF73