Miloslav Macko 1MA196 1MA196, Forum, Instrument, Remote, Control, Python, R&S Forum, RS Forum, R&SForum, RSForum R&S®Forum for Instrument Remote Control Using R&S®Forum Application for Instrument Remote Control Miloslav Macko 1MA196 1MA196, Forum, Instrument, Remote, Control, Python, R&S Forum, RS Forum, R&SForum, RSForum R&S®Forum for Instrument Remote Control Related products
28-Jun-2018 | AN-No. 1MA196
The UPL Audio Analyzer can be remote-controlled via the IEEE bus or the RS-232-C interface. Test results are output either individually or in blocks. ASCII or binary files such as setup files can be transferred to the audio analyzer from an external controller. This Application transfers files from the audio analyzer to an external controller via the serial interface. Utility programs for the audio analyzer and the external controller (PC) are required.
15-Nov-2001 | AN-No. 1GA42
Remote control of test and measurement equipment with a serial interface is limited to PC’s located in close proximity determined by the length of a typical serial cable connection (several feet). Usage of terminal server allows connecting through LAN or WAN networks thus controlling the instrument from further away even around the globe. The terminal server interfaces between TCP/IP protocol and the RS232 line. This application describes set-up of a popular terminal server from Black Box® Corporation to remotely and conveniently control the instruments EFA with EFA Scan software and DVRM or DVMD with Realtime Monitor / Stream Explorer software through a LAN or WAN network.
07-Jul-2003 | AN-No. 7BM41
This application note has been replaced by application note .
28-Aug-2009 | AN-No. 1MA45
The I/Q-Modulation Generator AMIQ provides high precision I/Q analog output for data calculated by the software WinIQSIM. Additionally, the software AMIQ-K2 enables you to read, convert, and transfer existing data files from various other programs to AMIQ format. Input formats supported by AMIQ-K2 are: - The propriety R&S programs IQSIM and DAB-K1. - Mathematic calculation programs like Matlab and Mathcad. - AWG202, COSSAP and ADS data files. AMIQ-K2 also provides you with remote control for AMIQ. For hardware and software requirements see section 2. AMIQ-K2 transfers data to AMIQ using either - GPIB - RS232. An extensive manual is supplied to help you use AMIQ-K2.
24-Nov-1999 | AN-No. 1MA10
Rohde & Schwarz signal generators can be connected in various ways to system controllers (typically PCs) and external PC peripherals. Although most of these connection operations are also explained in the instrument manuals, it is not always easy to maintain an overview. Operating manuals commonly focus on explaining a dedicated feature of a single instrument. This application note examines a range of typical user tasks and how to solve them with the different instruments.
26-Apr-2013 | AN-No. 1GP72
For several years, vehicle manufacturers and government agencies have sought ways to increase road safety, manage traffic efficiently and, in the future, make driving more comfortable, convenient and safe. Vehicle-to-everything (V2X) is a new generation of information and communication technology that connects vehicles to everything and can support these objectives. V2X is designed to offer low-latency vehicle-to-vehicle (V2V), vehicle-to-roadside infrastructure (V2I) and vehicle-to-pedestrian (V2P) communications to add a new dimension to future driver assistance systems.Cellular V2X (C-V2X) is defined as the communications standard by 3GPP in Release 14 and uses LTE technology as the physical interface for communications.The LTE C-V2X Scanner provides customers an opportunity to verify, test, and optimize ITS traffic systems that are being deployed or are already established. The scanner accomplishes this by passively listening to PC (5.9GHz) messages that are being broadcast from RSU (roadside units), vehicles or any other C-V2X enabled device. Traditional scanner measurements regarding RF signal power and quality such as RSRP, RS-CINR and RSSI, are provided for each physical channel (PSCCH and PSSCH) as well as decoded ITS message content for all three regions (North America, EU, China).
21-Oct-2022 | AN-No. 8NT07
Propagation measurements are indispensable in the planning of digital, cellular mobile radio net-works. To find the optimum sites for the base stations, a mobile test transmitter system simulating the base station is operated from a number of possible locations. The test receiver system is accommodated in a vehicle, which is driven along a test route to perform measurements. The parameters measured, such as level, bit error rate or channel impulse response, provide information on the coverage within the cell. The main problem is to minimize interference caused by multipath propagation in the reception area. The SME offered by Rohde & Schwarz is a universal test generator that can be used as the core of a test transmitter system. The SME generates the GMSK-modulated signals required for GSM propagation measurements in line with the rele-vant standards. Thanks to its low weight of 17 kg it can be carried even to remote sites. Fitted with the new optional DM Memory Extension (SME-B12, in the following referred to as XMEM), the SME is able to store data sequences of up to 8 Mbit which are long enough for receiver measurements with test mobile stations. A suitable test receiver system is for instance a test mobile station for measuring level and bit error rate and the Impulse Response Analyzer PCS from Rohde & Schwarz for measuring the channel impulse response. The present Application Note describes how the XMEM can be loaded with suitable data (test sequence) by the GSM Radiocommunication Test Set CRTP from Rohde & Schwarz and how the SME has to be adjusted for GMSK modulation of these data. First, however, an overview is given of all functions of the XMEM and their operation supplementary to the Operating Manual. Finally, it is explained how the XMEM data can be transferred between PC and SME via the IEEE-488 or RS-232 interface.
01-Jul-1999 | AN-No. 1GPAN14
Rohde & Schwarz offers a wide range of essential lab equipment, like power supplies, LCR meters and power analyzers. To enhance the versatility of these instruments, a selection of application programs is available. These application programs typically remote-control equipment for more complex tasks like sweeps, logging and battery testing.In a larger lab there may be a larger number of such instruments present, and a selection of available application programs installed on a PC. In such a case it is desirable to have a kind of dashboard providing an overview over both, including version check and links to documentation on the Rohde & Schwarz website. The R&S® application dashboard for power supplies and meters is providing this functionality. The application document contains the description and user manual for the software. Furthermore a package is provided containing installers for all related application programs.
13-Sep-2024 | AN-No. 1GP140
This application note applies to DC power supplies R&S®NGL200, R&S®NGM200, R&S®NGP800, R&S®NGU201 and R&S®NGU401, as well as LCR meters R&S®LCX100 and R&S®LCX200. It provides an overview over ethernet-based remote services provided by the referenced R&S® instruments. These services comprise an instrument web page, VNC remote control and FTP file transfer between the instrument and a remote computer. The application note gives instructions on how to set up the instrument and the remote computer in order to be able to utilize these services.
19-May-2022 | AN-No. 1GP135
The combination of R&S® CMU200 and R&S® UPV is in use for various tests of mobile phone speech functionality, such as acoustic tests according to 3GPP 26.132 or speech quality tests according to ITU-T P.862 (PESQ®) or ITU-T P.863 (POLQA®). This application note explains how to replace the R&S® CMU200 in these tasks with R&S® CMW500.
25-Jul-2014 | AN-No. 1GA65
All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies. In the case of parallel and serial connections it is usually desired to switch all channels simultaneously on and off for protecting the supplied circuitry and for avoiding overcurrent on other power supply channels.This application note describes how to connect and configure DC power supplies R&S®NGL200 and R&S®NGM200 for synchronized on and off switching of all channels across multiple power supplies.
15-Jun-2020 | AN-No. 1GP126
This application note is about measurement accuracy of the LCR-Meters R&S®LCX100 and R&S®LCX200. On the R&S®LCX100 and R&S®LCX200, the accuracy is calculated in real time, depending on the instrument settings and on the measured impedance. It is displayed on the lower part of the instrument display. If no test instrument is available, or information about the measurement accuracy at a certain measured impedance is sought without having a DUT at hand, this accuracy calculation tool provides the desired values.The document explains the background of the calculation and the prerequisites for installing and running the program. The installer provided installs the program on your PC.
11-May-2023 | AN-No. 1GP138
This application note is about creating your own battery model for the R&S®NGM200 or R&S®NGU201, beyond the standard models provided within the battery simulation option NGM-K106. The main purpose is to gradually discharge a battery or a rechargeable battery using the internal QuickArb function. The discharge of the battery can then be recorded using the fast data logging functionality FastLog. The recorded data are stored in a .CSV file. This file can then be adapted to be used as a battery model in the battery simulation mode of the R&S®NGM200. For this purpose, Rohde & Schwarz provides a tool for developers to make their work easier. This tool calculates all the data required for a battery model.Note: More advanced tools are available with application notes 1GP130 (Battery Cycle Tool) and 1GP136 (Battery Simulation).
26-Jul-2023 | AN-No. 1GP128
A large variety of measurements is performed in audio engineering in order to ensure transmission quality of analog and digital devices. An audio analyzer suitable for all these tasks will, therefore, incorporate a multitude of functions, resulting in a correspondingly large number of settings.This application note is to help test engineers using the R&S®UPP and R&S®UPV audio analyzers. It presents setting examples for all basic audio measurements to be performed immediately. For each setup, information is given on the type of measurement, the underlying standards, and on how to modify the graphic display results.
07-Jul-2014 | AN-No. 1GA64
This Application Note describes how the R&S® UPV and R&S® UPP200 audio analyzers can be used to replace the obsolete Agilent model 8903B audio analyzer in remote control applications.
24-Nov-2010 | AN-No. 1GA54
The LCR meters R&S®LCX100 and R&S®LCX200 precisely measure the complex impedance and the resulting components values over a wide frequency range. Dynamic impedance measurements allow to perform these measurements while sweeping the test signal frequency or other parameters like test signal level and DC bias. This application note provides a PC-based software tool for comfortably setting the sweeps and displaying the results in numerous charts.
14-Mar-2022 | AN-No. 1GP132
R&S®VISA is a standardized software library that allows fast communications over diverse interfaces with a wide variety of T&M instruments that are detected on the network from PC applications. R&S®VISA also includes a trace tool that simultaneously monitors communications between multiple applications and T&M instruments, and permits targeted analysis with the aid of efficient filters.
26-May-2020 | AN-No. 1DC02
This application program supports the logging and fast logging functionality of the power supplies R&S® NGM200, NGU201 and NGU401. Standard logging is also supported with power supply R&S® NGL200 and NGP800. Power supplies R&S® NGA100 and NGE100 are supported in the data collection mode. Charting functionality is available for logged voltage, current and power values.
14-Nov-2019 | AN-No. 1GP122
This application note describes how measurement results can be logged over time in the audio analyzer R&S® UPV. A Visual Basic.NET application program is included which stores results to ASCII files.
29-Jun-2012 | AN-No. 1GA59
Source measure units R&S®NGU401 and R&S®NGU201 are capable of precise current measurements from sub-microampere up to ampere. This application note provides a tool which generates a voltage or current sweep using the arbitrary function of the instruments. A fast log captures voltage and current values during the sweep. Subsequently the application program determines the voltage and current value for each sweep step and plots the results in an I-V curve .The tool can be utilized to characterize all kinds of two-pole devices like diodes, LEDs and solar panels.This application note can also be used in connection with DC power supplies R&S®NGM201 and R&S®NGM202.
15-Feb-2021 | AN-No. 1GP129
This application note provides an application program for level alignment, test automation and reporting with PESQ, POLQA and delay measurements on the Audio Analyzer R&S®UPV or R&S®UPV66.
08-May-2013 | AN-No. 1GA62
This application note proposes a digital level shifter for connecting the I2S interfaces R&S®UPP-B2 and R&S®UPV-B41 to devices under test with a logic voltage different from 3.3 V.
27-Mar-2020 | AN-No. 1GA71
This application note provides a tool for printing a report about measurement results on the audio analyzer R&S® UPV. The executable can be freely configured to include any result graphs and figures into the report. In addition it is an application example for a class library which can be included into custom application programs to add a printing function.
18-Jul-2011 | AN-No. 1GA57
Applications requiring higher voltages or currents, or a stack of voltage sources with taps in-between, demand the combination of several DC power supply channels in series or in parallel.All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies.When a large number of power supply channels is used, it is desirable to have a tool for configuring all instruments and channels from one user interface, and for keeping an overview over the states and measurement values from all channels.The application program of this application note provides such a tool. The document contains background information and user manual for the software.
27-Aug-2020 | AN-No. 1GP127
This application note is about creating your own battery model for the R&S®NGM200 and R&S®NGU201, beyond the standard models provided within the battery simulation option NGM-K106 and NGU-K106. To get to a battery model, a few steps are required. To determine the parameters for the battery model, it is necessary to discharge a battery using a selected method, to record the data and to calculate the model on this basis. With this software, a connection can be established to the instrument, batteries can be measured using various measurement methods, and a model can then be created from these measurements. These models, which are determined from the measurements, can then be simulated with the power supply, thus creating a digital twin of the battery. Using these, test scenarios can be carried out in a safe and reproducible environment.
21-Nov-2022 | AN-No. 1GP136
Most application notes for audio analyzer R&S® UPV include an application program which runs locally using the universal sequence controller option UPV-K1. This application note explains how sequence control programs can be modified to run on a remote PC using remote control option UPV-K4.
30-Jun-2012 | AN-No. 1GA60
This application note provides an application program for the audio analyzer R&S®UPV which calculates and displays the loudness of non-stationary sounds according to ISO 532-1 (Zwicker method). The theoretic background of the evaluation method is briefly explained.
14-Dec-2017 | AN-No. 1GA67
This application note explains how to use acoustic calibrations in order to be able to enter or read sound pressure level directly in the Audio Analyzer R&S® UPV. An application program is described which performs the necessary measurements for the calibration of microphones and loudspeakers, manages the calibration values and enters them into any appropriate user defined setup.
11-Oct-2012 | AN-No. 1GA47
This application note gives background information about the psychoacoustic measurements PESQ® (Perceptual Evaluation of Speech Quality) and PEAQ® (Perceptual Evaluation of Audio Quality). It also describes how to perform these measurements using the Rohde & Schwarz Audio Analyzer.
03-Apr-2009 | AN-No. 1GA49