513 Results
Up and down Chirp analysis in time and frequency domain Video, RTO2000, Oscilloscope, Analysis of complex radar signals Up and down Chirp analysis in time and frequency domain
Scopefield - Poster
R&S®RT-Zxx High Voltage and Current Probes - Specifications Brochures and Data Sheets Specifications
Russian version - времени простоя цифрового осциллографа на измерения
Russian version - Анализ джиттера с помощью цифрового осциллографа R&S®RTO
How to use realtime deembedding on a USB 3.1 Gen1 device video, oscilloscope, RTO2000, USB 3.1 How to use realtime deembedding on a USB 3.1 Gen1 device.
Video, oscilloscope, RTO2000, Time delay analysis of multiple wideband RF signals Analysis of multiple RF signals, which are typically used e.g. for direction finding.
Oscilloscope bus decoding, RTO2000, bus decoding, I2C Dive into your protocol to check for any problems with your I²C interface.
This application note along with its corresponding white paper 1MA207 show how to use the R&S radar product portfolio to tackle test and measurement tasks in modern radar technology.
10-Aug-2012 | AN-No. 1MA127
R&S VSE-K70x/FSx-K70x/FPx-K70x Vector Signal Analysis Application - Specifications
Generating models with a VNA and using these on an oscilloscope via the deembedding
23-May-2023 | AN-No. 1SL393
Discover some of the key parameters of an oscilloscope and how they impact on the performance in this video series: Part 1: Bandwidth and frequency response R&S®RTO2000 Video, application videos, oscilloscope, troubleshooting, mixed signal oscilloscope R&S Talking about bandwidth Open Lightbox Talking about bandwidth
The R&S®RTO-K92 eMMC Compliance Test option offers an automated test solution for the electrical interface of an eMMC device according to the JEDEC specification, revision 5.1. Oscilloscope Application Videos, Application Video, Application Videos, Videos, eMMC Interface Compliance Test Learn how you can use the eMMC compliance test of R&S for automated testings of electrical interfaces!
RTO2000, debugging, EMI When debugging EMI problems in electronic circuits, development engineers face the challenging problem of quickly and accurately identifying and eliminating the sources of unwanted emissions. Many problems can be eliminated during development by using oscilloscopes for EMI debugging.
This application note summarizes the Rohde &Schwarz test solutions for LTE-Advanced (Release 10) using Vector Signal Generators, Signal and Spectrum Analyzers and the Wideband Radio Communication Tester.
03-Sep-2014 | AN-No. 1MA166
Oscilloscope bus triggering, RTO2000, bus triggering, history mode, break condition Use the hardware trigger to isolate break conditions. Break conditions can be corellated with their root cause one by one using the History Mode.
Based on the new high-performance R&S®SMW200A vector signal generator and the R&S®RTO digital oscilloscope, the solution provides MIMO signal generation and realtime channel emulation (up to 4x4 or 8x2) as well as synchronous analysis of multiple TX antenna signals.
RTO2000, waveform display, R&S®SmartGrid, complex measurements Use the R&S®SmartGrid function to configure the display. For complex measurement tasks where several screen displays are helpful, you can superposition windows in multiple tabs. All measurement diagrams have labeled scales so you can immediately read important signal characteristics.
Compliance Testing, maximum output droop, RTO, Test Mode 6 A guide to carrying out a 100BASE-T1 compliance test for the MDI return loss using an R&S®ZND 2-port vector network analyser controlled by the ScopeSuite automation software.
This document provides an introduction to SDR as used for military radios and presents the relevant T&M solutions offered by Rohde & Schwarz.
15-Sep-2012 | AN-No. 1MA206
RTO2000, user interface, toolbar, display, cockpit The advanced user interface enables clear orientation thanks to colour coding, as well as having a high-resolution capacitive touchscreen with gesture support. The toolbar at the top of the screen provides access to frequently used functions such as measurements, zoom and FFT.
Video, RTO2000, Oscilloscope, Power integrity test Today’s highly integrated electronic devices use smaller voltage levels and therefore require much smaller ripple levels on the power rails for reliable operation.
Webinar, RTO2000, Automotive Ethernet compliance testing This webinar presents details on the individual test cases of the compliance test and provides useful information on the required test setup.
Oscilloscope bus debugging, RTO2000, bus debugging, UART, RS232, RS485 Let your Oscilloscope decode your UART/RS232/RS485 interfaces for you! So you can quickly understand the data and correlate the data content with the electrical signal.
RTO2000, toolbar, measurement functions, fast access The toolbar at the top of the screen provides access to frequently used functions such as measurements, zoom and FFT. Configure measurement in a few seconds by simply activating the measurement setup in the toolbar and choosing the desired measurement function and source channel in the sidebar.
For this video, we will be using a 2 GHz R&S®RTO oscilloscope, an 8 GHz R&S®ZND two-port VNA as well as the R&S®ScopeSuite automated test software. Webinar, Automotive, Ethernet This webinar will focus on 1000BASE-T1 automotive Ethernet compliance testing based on the Open Alliance (OA) TC8 specification for the physical layer.
The DUT operates in Test Mode 4 which is a PRBS sequence and it is exposed on a 125MHz disturber signal which comes out of theB6 signal generator which is integrated in the RTO6 oscilloscope. The ScopeSuite software provides a step by test foto guided test execution and reports the test results.
Comprehensive test solutions guide for production and R&D
Small cell is a compact base station with smaller form factor and lower transmission power in comparison to the conventional macro base station. It covers relatively small area and serves less users. Usually, small cell can be integrated into the existing mobile network. By the evolution of radio access technology, the role of small cell has been changing through the evolution path. In the 2G/3G time, its role was to provide coverage in corner cases. Later during LTE, networks are not just providing coverage but capacity too. Small cells were then used to provide the addition capacity where required without adding additional spectrum. Now in 5G era, network operators use densification as an important strategy to provide seamless 5G services which demand coverage, capacity and performance too. With use cases requiring the 5G millimeter wave (mmW) rollouts, it makes sense to use small cells for densification due to the propagation characteristics of mmW.In this application note, we will shed light on the testing aspects of a small cell throughout the product life cycle with particular focus on the production test solution for the small cell device under test (DUT) in FR2 (frequency range 2, mmW frequency band) in Over the Air (OTA) environment for option 6 split based on radio communication tester R&S®CMP200 and OTA chamber R&S®CMQ200. The document is complemented with more insights into test solutions used in typical R&D test applications towards the second half of the application note.
19-Jun-2023 | AN-No. 1SL395
12-Nov-2020 | Press Release | Automotive
Rohde & Schwarz supports the UNH-IOL in Automotive Ethernet testing services for OPEN Alliance TC9 test specificationTest and measurement specialist Rohde & Schwarz extends its support to the University of New Hampshire Interoperability Laboratory (UNH-IOL) with an extension to their compliance test services. As a result, UNH-IOL customers can now achieve compliance for automotive Ethernet cables and connectors (link segment) based on the OPEN Alliance TC9 working group test specification supporting both unshielded (UTP) and shielded twisted pair cables and connectors (STP).
The radio unit activity versus power consumption is monitored using the R&S RTO oscilloscope to detect short power pulses or spikes. The results make it easy to evaluate energy efficiency measures such as advanced sleep modes and provide ratings for radio units based on their power consumption.