R&S®Scope Rider handheld oscilloscope

R&S®Scope Rider handheld oscilloscope
Open Lightbox
R&S®Scope Rider handheld oscilloscope
Open Lightbox
R&S®Scope Rider handheld oscilloscope
Open Lightbox
R&S®Scope Rider handheld oscilloscope
Open Lightbox
R&S®Scope Rider handheld oscilloscope
Open Lightbox
R&S®Scope Rider handheld oscilloscope
Open Lightbox
R&S®Scope Rider handheld oscilloscope
Open Lightbox
R&S®Scope Rider handheld oscilloscope
Open Lightbox
R&S®Scope Rider handheld oscilloscope
Open Lightbox
R&S®Scope Rider Handheld Oscilloscope, Front view R&S®Scope Rider Handheld Oscilloscope, Front High R&S®Scope Rider Handheld Oscilloscope, Hero view R&S®Scope Rider Handheld Oscilloscope, Side view R&S®Scope Rider Handheld Oscilloscope, Front High R&S®Scope Rider Handheld Oscilloscope, Back view R&S®Scope Rider Handheld Oscilloscope, Side view R&S®Scope Rider Handheld Oscilloscope, Application Image R&S®Scope Rider Handheld Oscilloscope, Application Image

Key facts

  • Bandwidth: 60 MHz to 500 MHz
  • Sample rate: up to 5 Gsample/s
  • Memory depth: up to 500 kpts, 50 Mpts segmented memory
  • ADC resolution: 10-bit
  • Isolated channels (CAT IV 600 V (RMS) / CAT III 1000 V (RMS))

Lab performance in a rugged, portable design

When debugging embedded devices in the lab or analyzing complex problems in the field, the R&S®Scope Rider offers the performance and capabilities of a lab oscilloscope as well as the form factor and ruggedness of a battery-operated handheld device. Isolated channels combined with 500 MHz bandwidth makes it a perfect choice for power electronics applications. An integrated multimeter (two-channel model) or a multimeter mode (four-channel model) make the instrument the perfect tool for troubleshooting all kinds of electronics problems.

Features & benefits

Superior performance

Lab performance in a rugged, portable design

When debugging embedded devices in the lab or analyzing complex problems at the customer site, the R&S®Scope Rider offers the performance and capabilities of a lab oscilloscope as well as the form factor and ruggedness of a battery-operated handheld device.

37 automatic measurement functions with easy-to-understand graphical explanation
Open Lightbox

37 automatic measurement functions with easy-to-understand graphical explanation

A custom-designed 10-bit A/D converter and frontend IC provide the excellent resolution and linearity needed to display signals with high precision.

Eight instruments in one portable design

Debugging power in your hands

With the power of eight instruments, R&S®Scope Rider provides the capabilities and the flexibility needed to debug all kinds of electronic systems in the lab and in the field.

Lab performance oscilloscope
Open Lightbox

Lab performance oscilloscope

Lab performance oscilloscope, logic analyzer, protocol analyzer, data logger, digital multimeter, spectrum analyzer, harmonics analyzer, frequency counter

Intuitive to use

Capacitive touchpad and keypad operation

Making use of the latest display technology, R&S®Scope Rider offers a crystal-clear signal display with a high-resolution capacitive touch color display.

Intuitive to use
Open Lightbox

Intuitive to use

A central multifunction wheel allows quick adjustment of settings such as the trigger level or the vertical position of each channel.

Outstanding protection

CAT IV 600 V/CAT III 1000 V in an IP51 housing

Isolated inputs with CAT IV 600 V/CAT III 1000 V rating allow safe measuring in all environments. 

Overview of measurement categories CAT I through CAT IV
Open Lightbox

Overview of measurement categories CAT I through CAT IV

Unmatched connectivity

And much more

Wireless LAN* and Ethernet for web-based remote control, easy documentation of measurement results and more than four hours of battery power make the R&S®Scope Rider the right tool for your everyday troubleshooting needs in the lab and in the field.
* Not available in all countries. For more information, see our datasheet.

Unmatched connectivity
Open Lightbox

Unmatched connectivity

Available models

Available models
Models
Bandwidth
Channels
Sample rate
Max. memory depth
Optional MSO
Starting at

R&S®RTH1002

Order number 1317.5000P02

Click on order no. to copy
Order number 1317.5000P02 is now copied to your clipboard.
Bandwidth
60 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
500 kpts
Optional MSO
8 digital channels
Starting at
Price On Request

R&S®RTH1004

Order number 1317.5000P04

Click on order no. to copy
Order number 1317.5000P04 is now copied to your clipboard.
Bandwidth
60 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
500 kpts
Optional MSO
8 digital channels
Starting at
Price On Request

R&S®RTH1002 + RTH-B221

Order number 1317.5000P12

Click on order no. to copy
Order number 1317.5000P12 is now copied to your clipboard.
Bandwidth
100 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
500 kpts
Optional MSO
8 digital channels
Starting at
Price On Request

R&S®RTH1004 + RTH-B241

Order number 1317.5000P14

Click on order no. to copy
Order number 1317.5000P14 is now copied to your clipboard.
Bandwidth
100 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
500 kpts
Optional MSO
8 digital channels
Starting at
Price On Request

R&S®RTH1002 + RTH-B222

Order number 1317.5000P22

Click on order no. to copy
Order number 1317.5000P22 is now copied to your clipboard.
Bandwidth
200 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
500 kpts
Optional MSO
8 digital channels
Starting at
Price On Request

R&S®RTH1004 + RTH-B242

Order number 1317.5000P24

Click on order no. to copy
Order number 1317.5000P24 is now copied to your clipboard.
Bandwidth
200 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
500 kpts
Optional MSO
8 digital channels
Starting at
Price On Request

R&S®RTH1002 + RTH-B223

Order number 1317.5000P32

Click on order no. to copy
Order number 1317.5000P32 is now copied to your clipboard.
Bandwidth
350 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
500 kpts
Optional MSO
8 digital channels
Starting at
Price On Request

R&S®RTH1004 + RTH-B243

Order number 1317.5000P34

Click on order no. to copy
Order number 1317.5000P34 is now copied to your clipboard.
Bandwidth
350 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
500 kpts
Optional MSO
8 digital channels
Starting at
Price On Request

R&S®RTH1002 + RTH-B224

Order number 1317.5000P52

Click on order no. to copy
Order number 1317.5000P52 is now copied to your clipboard.
Bandwidth
500 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
500 kpts
Optional MSO
8 digital channels
Starting at
Price On Request

R&S®RTH1004 + RTH-B244

Order number 1317.5000P54

Click on order no. to copy
Order number 1317.5000P54 is now copied to your clipboard.
Bandwidth
500 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
500 kpts
Optional MSO
8 digital channels
Starting at
Price On Request
Specifications
Vertical system
Analog channels R&S®RTH1002
R&S®RTH1012/R&S®RTH1022
R&S®RTH1032/R&S®RTH1052
2
R&S®RTH1004/R&S®RTH1014/R&S®RTH1024/R&S®RTH1034/R&S®RTH1054 4
Digital channels (opt.) 8
Bandwidth (-3 dB) R&S®RTH1002 and R&S®RTH1004
R&S®RTH1012 and R&S®RTH1014
R&S®RTH1022 and R&S®RTH1024
R&S®RTH1032 and R&S®RTH1034
R&S®RTH1052 and R&S®RTH1054
60 MHz,
100 MHz,
200 MHz,
350 MHz,
500 MHz
Rise time R&S®RTH1002 and R&S®RTH1004
R&S®RTH1012 and R&S®RTH1014
R&S®RTH1022 and R&S®RTH1024
R&S®RTH1032 and R&S®RTH1034
R&S®RTH1052 and R&S®RTH1054
60 MHz, <5.8 ns
100 MHz, <3.5 ns
200 MHz, <1.75 ns
350 MHz, <1 ns
500 MHz, <700 ps
Input impedance 1 MΩ ± 1 % || 12 pF ± 2 pF (meas.)
Input sensitivity 2 mV/div to 100 V/div
ADC resolution 10 bit
Offset range +/-200 V
Maximum input voltage CAT IV 300 V (RMS), 424 V (Vp)
CAT IV 600 V, CAT III 1000 V
Acquisition system
Realtime sampling rate 1/2/4 channels active 5/2.5/1.25 Gsample/s
Acquisition memory 1/2/4 channels active 500/250/125 ksample/channel
Max. acquisition rate 50,000 waveforms/s
Decimation modes sample, high resolution, peak detect
Waveform arithmetics envelope, average
Horizontal system
Timebase range 1 ns/div to 500 s/div
Accuracy (after delivery/calibration) ±10 ppm
Channel deskew ±100 ns
Trigger system
Standard Trigger types edge, glitch, width
Optional Trigger types TV/Video, pattern, state, runt, slew rate, window, Data2clock, serial pattern, timeout, interval, protocol
Analysis and measurement functions
Automatic measurements 37 measurement functions
Mask testing
Mask definition tolerance tube
Actions on violation none, beep, stop
History and segmented memory
Number of segments up to 5000
Protocol trigger and decode
Supported protocols (optional: R&S®RTH-K1, R&S®RTH-K2, R&S®RTH-K3, R&S®RTH-K9, R&S®RTH-K10) I2C, UART/RS-232/RS-422/RS-485, CAN, LIN, CAN-FD, SENT
Logic analyzer (MSO) functionality
Digital input channels 8
General data
Dimensions W x H x D 201 mm x 293 mm x 74 mm
(7.91 in x 11.54 in x 2.91 in)
Weight with battery 2.4 kg (5.3 lb) (nom.)
Display 7.0" LC TFT 800 x 480 color display
Interfaces USB host, USB device, LAN, wireless LAN (optional)
Operating system Embedded
Data logger
Number of simult. logging channels 4
Measurement speed 1/2/5 measurements/s
Memory depth 2 Msample per logging channel
Digital voltmeter/digital multimeter
Resolution 2-channel version (digital multimeter): 11 000 counts
4-channel version (digital voltmeter): 999 counts
Voltage and current current with optional current probe or shunt DC, AC, AC+DC
Temperature with PT100 temperature sensor
IP rating IP51, in line with IEC 60529

Available options

General
Product
Description

Order number 1325.9981.02

Click on order no. to copy
Order number 1325.9981.02 is now copied to your clipboard.
Description

Mixed signal option: 250 MHz

Turns the R&S®RTH oscilloscopes into fast, precise and portable mixed signal oscilloscopes (MSO).

Bandwidth upgrade
Product
Description
R&S®RTH-B221

Order number 1325.9717.02

Click on order no. to copy
Order number 1325.9717.02 is now copied to your clipboard.
Description

Bandwidth upgrade of the R&S®RTH1002 to 100 MHz

R&S®RTH-B222

Order number 1325.9723.02

Click on order no. to copy
Order number 1325.9723.02 is now copied to your clipboard.
Description

Bandwidth upgrade of the R&S®RTH1002 to 200 MHz

R&S®RTH-B223

Order number 1325.9730.02

Click on order no. to copy
Order number 1325.9730.02 is now copied to your clipboard.
Description

Bandwidth upgrade of the R&S®RTH1002 to 350 MHz

R&S®RTH-B224

Order number 1326.0571.02

Click on order no. to copy
Order number 1326.0571.02 is now copied to your clipboard.
Description

Bandwidth upgrade of the R&S®RTH1002 to 500 MHz

R&S®RTH-B241

Order number 1326.0588.02

Click on order no. to copy
Order number 1326.0588.02 is now copied to your clipboard.
Description

Bandwidth upgrade of the R&S®RTH1004 to 100 MHz

R&S®RTH-B242

Order number 1326.0594.02

Click on order no. to copy
Order number 1326.0594.02 is now copied to your clipboard.
Description

Bandwidth upgrade of the R&S®RTH1004 to 200 MHz

R&S®RTH-B243

Order number 1326.0607.02

Click on order no. to copy
Order number 1326.0607.02 is now copied to your clipboard.
Description

Bandwidth upgrade of the R&S®RTH1004 to 350 MHz

R&S®RTH-B244

Order number 1326.0613.02

Click on order no. to copy
Order number 1326.0613.02 is now copied to your clipboard.
Description

Bandwidth upgrade of the R&S®RTH1004 to 500 MHz

Serial triggering and decoding
Product
Description

Order number 1325.9969.02

Click on order no. to copy
Order number 1325.9969.02 is now copied to your clipboard.
Description

I²C/SPI triggering and decoding

Analysis of I2C and SPI signals on analog and logic channels.

Order number 1325.9975.02

Click on order no. to copy
Order number 1325.9975.02 is now copied to your clipboard.
Description

UART/RS-232 triggering and decoding

Analysis of UART/RS-232/422/485 signals on analog and logic channels.

Order number 1333.0550.02

Click on order no. to copy
Order number 1333.0550.02 is now copied to your clipboard.
Description

CAN/LIN triggering and decoding

Analysis of CAN and LIN signals on analog and logic channels.

Order number 1326.3829.02

Click on order no. to copy
Order number 1326.3829.02 is now copied to your clipboard.
Description

CAN-FD triggering and decoding

Analysis of CAN-FD signals on analog and logic channels. Requires R&S®RTH-K3.

Order number 1326.3835.02

Click on order no. to copy
Order number 1326.3835.02 is now copied to your clipboard.
Description

SENT triggering and decoding

Analysis of SENT signals on analog and logic channels.

General analysis
Product
Description

Order number 1326.1803.02

Click on order no. to copy
Order number 1326.1803.02 is now copied to your clipboard.
Description

History and segmented memory

Order number 1333.0680.02

Click on order no. to copy
Order number 1333.0680.02 is now copied to your clipboard.
Description

Spectrum analysis

Order number 1326.0642.02

Click on order no. to copy
Order number 1326.0642.02 is now copied to your clipboard.
Description

Advanced trigger

Order number 1333.0696.02

Click on order no. to copy
Order number 1333.0696.02 is now copied to your clipboard.
Description

Frequency counter

Order number 1333.0673.02

Click on order no. to copy
Order number 1333.0673.02 is now copied to your clipboard.
Description

Harmonic analysis

Other
Product
Description
R&S®RTH-K38

Order number 1801.4632.02

Click on order no. to copy
Order number 1801.4632.02 is now copied to your clipboard.
Description

User scripting

Order number 1326.0620.02

Click on order no. to copy
Order number 1326.0620.02 is now copied to your clipboard.
Description

Wireless LAN, all countries except US, Canada and EU

Order number 1332.9890.02

Click on order no. to copy
Order number 1332.9890.02 is now copied to your clipboard.
Description

Wireless LAN, for US and Canada, only

Order number 1326.0636.02

Click on order no. to copy
Order number 1326.0636.02 is now copied to your clipboard.
Description

Web interface remote control

General accessories
Product
Description
R&S®RT-ZA12

Order number 1333.0809.02

Click on order no. to copy
Order number 1333.0809.02 is now copied to your clipboard.
Description

PT100 temperature probe (4 mm Banana plug)

Order number 1326.1978.02

Click on order no. to copy
Order number 1326.1978.02 is now copied to your clipboard.
Description

Accessory replacement set for R&S®RT-ZI10 and R&S®RT-ZI11

Contains push-on hook clip, push-on reference contact, reference lead with crocodile clip, push-on insulating sleeve, set of color clips.

Order number 1326.1984.02

Click on order no. to copy
Order number 1326.1984.02 is now copied to your clipboard.
Description

Accessory extension set for R&S®RT-ZI10 and R&S®RT-ZI11

Contains test clip with steel jaws, push-on safety jaw clip, silicone-insulated reference leads, push-on Ø 4 mm test probe, Ø 2 mm reference lead with hook clip, BNC male connector to Ø 4 mm sockets, push-on BNC male connector.

Order number 1326.0988.02

Click on order no. to copy
Order number 1326.0988.02 is now copied to your clipboard.
Description

Safety test leads, red and black, silicone, 600 V CAT IV

R&S®HA-Z220

Order number 1309.6175.00

Click on order no. to copy
Order number 1309.6175.00 is now copied to your clipboard.
Description

Carrying bag

R&S®HA-Z210

Order number 1309.6152.00

Click on order no. to copy
Order number 1309.6152.00 is now copied to your clipboard.
Description

Spare LAN cable

R&S®HA-Z211

Order number 1309.6169.00

Click on order no. to copy
Order number 1309.6169.00 is now copied to your clipboard.
Description

Spare USB cable

R&S®RTH-Z4

Order number 1326.2774.02

Click on order no. to copy
Order number 1326.2774.02 is now copied to your clipboard.
Description

Hard shell protective carrying case

Dimensions: 455 mm x 368 mm x 166 mm. Weight: 2.5 kg.

R&S®HA-Z302

Order number 1321.1340.02

Click on order no. to copy
Order number 1321.1340.02 is now copied to your clipboard.
Description

Power supply for vehicles

Powers the instrument and the R&S®HA-Z303 external battery charger

R&S®HA-Z303

Order number 1321.1328.02

Click on order no. to copy
Order number 1321.1328.02 is now copied to your clipboard.
Description

External battery charger

Charges batteries outside of the instrument

R&S®HA-Z306

Order number 1321.1334.02

Click on order no. to copy
Order number 1321.1334.02 is now copied to your clipboard.
Description

Battery pack

Lithium-ion battery with discharge indicator, 6.4 Ah

R&S®RT-ZA14

Order number 1326.2874.02

Click on order no. to copy
Order number 1326.2874.02 is now copied to your clipboard.
Description

Spare power supply for R&S®Scope Rider

Order number 1800.2707.00

Click on order no. to copy
Order number 1800.2707.00 is now copied to your clipboard.
Description

Accessory kit for R&S®RT-ZHD probes and R&S®Scope Rider multimeter

Contains 2 x safety alligator clip, 2 x pincer clip, 2 x test clip, 2 x spade terminal, 2 x lead 17 cm, 2 x lead 100 cm

Passive probes
Product
Description

Order number 1326.1761.02

Click on order no. to copy
Order number 1326.1761.02 is now copied to your clipboard.
Description

Passive probe, 500 MHz, 10:1, isolated

Order number 1326.3106.02

Click on order no. to copy
Order number 1326.3106.02 is now copied to your clipboard.
Description

Compact passive probe, 500 MHz, 10:1, isolated

Order number 1326.1810.02

Click on order no. to copy
Order number 1326.1810.02 is now copied to your clipboard.
Description

Passive probe, 500 MHz, 100:1, isolated

Current probes
Product
Description

Order number 1333.0850.02

Click on order no. to copy
Order number 1333.0850.02 is now copied to your clipboard.
Description

AC/DC 20 kHz current probe

Order number 1333.0844.02

Click on order no. to copy
Order number 1333.0844.02 is now copied to your clipboard.
Description

100 kHz current probe

Order number 1801.4932.02

Click on order no. to copy
Order number 1801.4932.02 is now copied to your clipboard.
Description

120 MHz current probe

Application bundles
Product
Description
R&S®RTH-PK1

Order number 1801.3242.02

Click on order no. to copy
Order number 1801.3242.02 is now copied to your clipboard.
Description

Application bundle (R&S®RTH-K1, K2, K3, K9, K10, K15, K18, K19, K33, K34, K38 and K201)

Contains trigger and decoding I²C/SPI (R&S®RTH-K1), UART/RS-232 (R&S®RTH-K2), CAN/LIN (R&S®RTH-K3), CAN-FD (R&S®RTH-K9), SENT (R&S®RTH-K10), history and segmented memory (R&S®RTH-K15), spectrum analysis (R&S®RTH-K18), advanced trigger (R&S®RTH-K19), frequency counter (R&S®RTH-K33), harmonic analysis (R&S®RTH-K34), user scripting (R&S®RTH-K38) and web interface remote control (R&S®RTH-K201) for R&S®RTH models

Application packages
Product
Description
R&S®RTH-PKPWR

Order number 1338.0413.02

Click on order no. to copy
Order number 1338.0413.02 is now copied to your clipboard.
Description

Power electronics bundle (R&S®RTH-K15, -K19, -K34)

Power electronics bundle, contains history and segmented memory (R&S®RTH-K15), advanced triggering (R&S®RTH-K19) and harmonics analysis (R&S®RTH-K34)

R&S®RTH-ZELEC

Order number 1338.0436P02

Click on order no. to copy
Order number 1338.0436P02 is now copied to your clipboard.
Description

Industrial bundle (R&S®RTH-Z4; R&S®HA-Z303, -Z306)

Industrial bundle, contains hard shell protective carrying case (R&S®RTH-Z4), battery charger for lithium-ion battery (R&S®HA-Z303) and replacement lithium-ion battery pack (R&S®HA-Z306)

R&S®RTH-PKAUTO

Order number 1338.0420.02

Click on order no. to copy
Order number 1338.0420.02 is now copied to your clipboard.
Description

Automotive bundle (R&S®RTH-K3, -K9, -K10)

Automotive bundle, contains trigger and decoding CAN/LIN (R&S®RTH-K3), CAN-FD (R&S®RTH-K9) and SENT (R&S®RTH-K10)

Application videos

Oscilloscopes – Designed for you. Not for the hype

Affordable digital oscilloscopes with outstanding features. Wowee, are we right?

29-Aug-2024

Also interesting for you

10 years of Rohde & Schwarz oscilloscope innovation

What do our devices have in common? They are precise, compact and versatile, and find signal errors quickly. What makes them different and outstanding?

More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.