26 Results
Versatile Software Tool for Rohde & Schwarz Instruments
RSCommander is a versatile software tool for a wide range of Rohde & Schwarz spectrum-, network analyzers, signal generators and oscilloscopes. It allows for automatic instrument discovery, making screenshots, reading traces, file transfer and simple script creation.
24-Dec-2017 | AN-No. 1MA074
Noise Power Ratio Signal Generation and Measurement
Noise Power Ratio (NPR) is an add-on tool for WinIQSIM™ to generate noise power ratio stimulus signals and measure the resulting noise power ratio of a device under test (DUT) using Rohde & Schwarz instruments via LAN or GPIB bus.
06-Nov-2015 | AN-No. 1MA29
A Test Port Adapter System is implemented for all Rohde & Schwarz equipment, which operates above 26 GHz in order to protect the RF front-end from mechanical damage. The Test Port Adapter System consists of an RF front-end interface called the Test Port Adapter Body, and the Test Port Adapter Head which is attached to the Body. The Head provides an interface to a cable or device under test. This Application Note identifies the various types of Test Port Adapters, their parameters, compatibilities and usages.
28-Apr-2015 | AN-No. 1MA100
The use of Rohde & Schwarz device drivers under VEE software is not complicated. However, a number of factors are involved, the errors that occur are often difficult to diagnose. This application provides easy and detailed support for installation and troubleshooting using National Instruments or Agilent GPIB boards.
20-Dec-2012 | AN-No. 1MA035
This application note gives a short summary on how to use harmonic mixers in combination with Rohde & Schwarz Signal and Spectrum Analyzers. Focus of this application note is the use of conversion loss tables with different R&S analyzers. It also provides a tool to convert different formats of the conversion loss tables.
06-Aug-2010 | AN-No. 1EF75
Application note 1MA25 has been replaced by application note .
28-Aug-2009 | AN-No. 1MA25
Spectrum and network analyzers are capable of measuring large amounts of data that require complex mathematical processing; MATLAB is a powerful tool for such operations. This application note describes how instruments can be controlled directly from MATLAB scripts and how measurement data can be imported into MATLAB. Only 32-bit MATLAB is supported.
24-Sep-2007 | AN-No. 1EF46
This application note describes the different memory types and locations that user information can be stored in a spectrum analyzer R&S® FSEA, R&S® FSEB, R&S® FSEM, R&S® FSEK or R&S® FSIQ, as well as the different ways in which it can be erased/cleared for security reasons.
20-Sep-2004 | AN-No. 1EF54
In digital wireless communication systems one or multiple users are assigned to a physical RF channel. With analog systems only one user per carrier is possible. Output spectrum of the transmitter has to be restricted to the assigned channel in order to avoid interference with the neighbor channels. With the switch over to digital modulation formats more user per channel are possible. They share one channel by using only part of the time for transmission (Time Division Multiplex Access, TDMA) or by coding the transmission by orthogonal sequences for distinction to other users (Code Division Multiples Access, CDMA). Beneath the restriction of modulation spectrum with TDMA systems also time behavior of the transmitted signal is critical. One reason is that in a multi-user situation only one user is allowed to transmit within his assigned time slots. Another reason is that by switching a carrier on and off spectrum of the transmitter splatters and causes additional interference in other RF channels.
17-Jan-2002 | AN-No. 1EF32
The following application note describes the function and operation of user menus for FSE Spectrum Analyzers including option Vector Signal Analysis (FSE-B7). For measurements according to the PCS 1900 standard user menus are provided, which perform settings on FSE for Base Station testing required in the standard. The menu and the accompanying setups are stored on a floppy disk. For operation of the menus firmware version 1.40 or higher is required. Option Vector Signal Analysis FSE-B7 has to be installed for the use of the application menu.
17-Jan-2002 | AN-No. 1EF24
In addition to frequency, power and long-term stability, short-term stability or its equivalent, phase noise, is an important characteristic of signal sources. For example, the phase noise of conversion oscillators of receivers obtained in the presence of a strong signal determines adjacent-channel sensitivity. In the case of transmitters, the phase noise of the oscillator together with the modulator characteristics is responsible for the power generated in adjacent channels. The phase noise of oscillators or synthesizers and the relevant measurements therefore play an important role in radio transmission systems.
16-Jan-2002 | AN-No. 1EF16
Measuring the spurious emissions of transmitters used in GSM, DCS 1800 and PCS 1900 networks requires highly complex test setups since con-ventional spectrum analyzers do not have the necessary dynamic range. To obtain this range, notch filters are used to suppress the useful sig-nal. The spectrum analyzers of the FSE family make it possible for the first time to verify com-pliance with stipulated limit values for spurious emissions within the transmission band and out-side the reception band without the use of notch filters. The measurement problem and its solution by means of FSE are described in the following by way of the example of a GSM base station.
16-Jan-2002 | AN-No. 1EF17
TDMA communications systems like GSM, DCS 1800 or PCS 1900 make effective use of the frequency spectrum by assigning several subscribers to the same frequency channel. Each subscriber has access to one predefined time slot for transmitting information. With GSM eight subscribers share one frequency channel with a bandwidth of 200 kHz. In order not to disturb the other users of the 200-kHz channel it has to be ensured that, for instance, a mobile sends in the assigned time slot only and that no power is emitted by the transmitter at other times. For this reason the transmitter power is practically switched off in the transmission intervals.
16-Jan-2002 | AN-No. 1EF18
The following application note describes the function and operation of user menus for FSE Spectrum Analyzers including option Vector Signal Analysis (FSE-B7). For measurements according to the GSM standard user menus are provided, which perform settings on FSE for Base Station testing required in the standard. The menu and the accompanying setups are stored on a floppy disk. For operation of the menus firmware version 1.40 or higher is required. Option Vector Signal Analysis FSE-B7 has to be installed for the use of the application menu.
16-Jan-2002 | AN-No. 1EF23
Adjacent Channel Power performance of power amplifiers used in digital TV systems has to be guaranteed over a wide frequency range, 54 to 890 MHz, which may lead to time consuming test procedures. The application software described here provides swept ACP analysis, using AMIQ and SMIQ for signal generation and FSP, FSU or FSE for signal analysis. ACP measurement is performed according to FCC Regulation 47CFR 73.622(h).
16-Oct-2001 | AN-No. 1MA43
Power amplifiers in digital TDMA mobile phones are fed with current only during the active slot to save power. Using conventional measuring equipment, the noise figure, an important parameter in power amplifiers, can only be determined with the amplifier in continuous operation. However, continuous operation can lead to amplifier overload and produce distorted results. Now there is a convenient way of determining the noise figure of amplifiers with pulsed power supply: using a Spectrum Analyzer (FSP or FSE or FSIQ or ESI), Noise Measurement Software FS-K3 and a function or pulse generator.
19-Dec-2000 | AN-No. 1MA32
The combination of an SMIQ Signal Generator and an FSE / FSIQ Analyzer enables the most important transmitter and receiver tests on ICO user terminals in quality management and development. This application note presents a series of quick tests in unsynchronized, non-signalling mode. To facilitate integration of SMIQ and FSE / FSIQ into existing test systems, complex instrument settings are supplied as sets of IEC/IEEE-bus commands. Sample files with burst data for uplink and downlink signals allow the configuration, execution and optimization of the tests described, even without a DUT.
08-May-2000 | AN-No. 1MA23
The CMD 57/59 output level for BER measurement can be calibrated to high accuracy to match GSM 11.21, (with modulated signals and adjacent timeslots + 50 dB above the used timeslot) using a simple test setup containing an NRVD power meter and an FSE spectrum analyzer.
10-Mar-2000 | AN-No. 1MA24
MobiDemo is an application software for controlling a combination of Generator SMIQ and Analyzer FSE/ FSE-B7 or FSIQ. MobiDemo offers a convenient user interface to facilitate testing of components used in digital mobile radio systems, for instance amplifiers or filters. The software can handle the GSM, PHS, IRIDIUM, IS-95 and W-CDMA standards. The corresponding test signals can be activated on SMIQ with a few keystrokes and mouse clicks. FSE/FSIQ is set up in accordance with SMIQ and analyzes signals in the modulation analysis or adjacent-channel power measurement mode. The settings for SMIQ and FSE/FSIQ are transferred via the IEC/IEEE bus.
09-Jul-1999 | AN-No. 1MA11
This application note describes the principle of harmonic mixing and the requirements to be met by spectrum analyzers and external mixers.
05-Mar-1999 | AN-No. 1EF43
An FSE Spectrum Analyser equipped with the Vector Signal Analysis option (FSE-B7) can measure oscillator settling time or transmitter attack and release times with high accuracy up to 40 GHz. No additional measurement equipment is needed.
12-Feb-1999 | AN-No. 1MA15
A test setup is described for easy demonstration of the Bit Error Rate Test (BERT) function of AMIQ/AMIQ-B1. The test setup contains I/Q Modulation Generator AMIQ/AMIQ-B1 controlled by I/Q Simulation Software WinIQSIM, Vector Signal Generator SMIQ and Spectrum/Vector Signal Analyzer FSE/FSE-B7. The FSE with FSE-B7 is used as online FSK demodulator (setting: Analog demodulation, FM Signal, DC coupling, Real Time On) to demodulate the SMIQ RF signal FSK-modulated by PRBS data. The AMIQ is controlled by WinIQSIM software and receives the demodulated AF output signal from the FSE for BER testing.
29-Sep-1998 | AN-No. 1MA16
DECT standard ETS 300 175-2 prescribes among others measurement of the transmit power and the unwanted power in adjacent channels. Following a brief introduction into DECT, this Application Note describes the standard-conforming measurement of the normal transmit power NTP and the unwanted adjacent-channel power ACP using a spectrum analyzer from the FSE family ( firmware version 1.63 and higher). Option FSE-B7 (Vector Signal Analyzer) is required for measuring the normal transmit power NTP since the signal must be demodulated for this measurement. Due to the wide dynamic range of FSEA20 and FSEA30, the adjacent channel power ACP can be measured without bandpass filters suppressing the transmit channel. Option FSE-B7 is not required for measuring the adjacent-channel power.
28-Apr-1998 | AN-No. 1EF42
Use of FSE Spectrum Analyzer for adjacent channel power measurements with wideband CDMA signals is explained. Optimum operation is shown by explanation the signal behavior and the internal structure of the FSE. The spectrum analyzer family FSE, featuring a very high dynamic range is an outstanding equipment for this purpose. Up to 73 dB dynamic range are attained.
17-Mar-1998 | AN-No. 1EF40
Level or power measurement of especially modulated signals using spectrum analyzers is becoming more and more important . Whereas the first choice in terms of accuracy for power measurement of any carrier (modulated or non-modulated) is a power meter, power measurement of spurious or in the adjacent channel of a transmission system needs a selective power meter with high dynamic range. A power meter, however, is a non-selective device with limited dynamic range and is not appropriate for these types of measurements. The first choice is a spectrum analyzer because of its versatile use as a general-purpose instrument. Compared to a power meter its power measurement accuracy is worse. In general this can be overcome by substitution methods using a power meter, an attenuator and a signal generator. But substitution is time-consuming and requires more investment in test equipment than a single instrument. Therefore it is most important to have a spectrum analyzer like the FSE, which can fulfill at least most of the requirements in terms of measurement accuracy.
13-Jan-1998 | AN-No. 1EF36
The following application note describes the function and operation of user menus for FSE Spectrum Analyzers including option Vector Signal Analysis (FSE-B7). For measurements according to the PCS 1900 standard for Mobile Stations user menus are provided, which perform settings on FSE for the different measurements required in the standard. The menu and the accompanying setups are stored on a floppy disk.
01-Nov-1996 | AN-No. 1EF22