Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1120 Results
Rohde & Schwarz offers a wide range of essential lab equipment, like power supplies, LCR meters and power analyzers. To enhance the versatility of these instruments, a selection of application programs is available. These application programs typically remote-control equipment for more complex tasks like sweeps, logging and battery testing.In a larger lab there may be a larger number of such instruments present, and a selection of available application programs installed on a PC. In such a case it is desirable to have a kind of dashboard providing an overview over both, including version check and links to documentation on the Rohde & Schwarz website. The R&S® application dashboard for power supplies and meters is providing this functionality. The application document contains the description and user manual for the software. Furthermore a package is provided containing installers for all related application programs.
13-Sep-2024 | AN-No. 1GP140
This application note is about measurement accuracy of the LCR-Meters R&S®LCX100 and R&S®LCX200. On the R&S®LCX100 and R&S®LCX200, the accuracy is calculated in real time, depending on the instrument settings and on the measured impedance. It is displayed on the lower part of the instrument display. If no test instrument is available, or information about the measurement accuracy at a certain measured impedance is sought without having a DUT at hand, this accuracy calculation tool provides the desired values.The document explains the background of the calculation and the prerequisites for installing and running the program. The installer provided installs the program on your PC.
11-May-2023 | AN-No. 1GP138
This application note investigates and discusses the influence of wideband noise on harmonic distortion measurements.
06-Jul-2011 | AN-No. 1GA55
This application note applies to DC power supplies R&S®NGL200, R&S®NGM200, R&S®NGP800, R&S®NGU201 and R&S®NGU401, as well as LCR meters R&S®LCX100 and R&S®LCX200. It provides an overview over ethernet-based remote services provided by the referenced R&S® instruments. These services comprise an instrument web page, VNC remote control and FTP file transfer between the instrument and a remote computer. The application note gives instructions on how to set up the instrument and the remote computer in order to be able to utilize these services.
19-May-2022 | AN-No. 1GP135
Useful tips and tricks for your first measurement experience
Resistors, capacitors and inductors are the most basic components in electric circuits. It must be ensured that they work properly and accurately. Therefore, they need to be tested thoroughly during circuit design. This is usually done using LCR meters, which have become indispensable in the lab and in production. This application note looks at how to perform basic capacitor and inductor measurements accurately and reliably.
22-Feb-2024 | AN-No. 1GP142
This application note explains how to use the Audio Analyzer R&S UPV for measurements of maximum sound pressure level of headphones according to EN50332. It is possible to measure a combination of music player / FM receiver and headphones, the maximum output voltage of a player / FM receiver alone or the wideband characteristic voltage of headphones alone. An application program is available for download as installer file and as VB.NET project.
17-Jun-2009 | AN-No. 1GA48
R&S®VISA is a standardized software library that allows fast communications over diverse interfaces with a wide variety of T&M instruments that are detected on the network from PC applications. R&S®VISA also includes a trace tool that simultaneously monitors communications between multiple applications and T&M instruments, and permits targeted analysis with the aid of efficient filters.
26-May-2020 | AN-No. 1DC02
This application note explains how to use acoustic calibrations in order to be able to enter or read sound pressure level directly in the Audio Analyzer R&S® UPV. An application program is described which performs the necessary measurements for the calibration of microphones and loudspeakers, manages the calibration values and enters them into any appropriate user defined setup.
11-Oct-2012 | AN-No. 1GA47
A large variety of measurements is performed in audio engineering in order to ensure transmission quality of analog and digital devices. An audio analyzer suitable for all these tasks will, therefore, incorporate a multitude of functions, resulting in a correspondingly large number of settings.This application note is to help test engineers using the R&S®UPP and R&S®UPV audio analyzers. It presents setting examples for all basic audio measurements to be performed immediately. For each setup, information is given on the type of measurement, the underlying standards, and on how to modify the graphic display results.
07-Jul-2014 | AN-No. 1GA64
Application program with documentation for sending a sequence of logged SCPI commands to the firmware of the R&S® Audio Analyzer UPV.
19-Jul-2010 | AN-No. 1GA53
This application note provides software and instructions for a simple check of the acoustic performance of mobile phones. It targets mainly service centers and repair workshops which have to perform incoming tests of defective mobile phones and final tests of repaired mobiles. A focus is set on short test times and ease of use, without compromising accuracy and repeatability of results.
14-Dec-2017 | AN-No. 1GA69
This application note describes how measurement results can be logged over time in the audio analyzer R&S® UPV. A Visual Basic.NET application program is included which stores results to ASCII files.
29-Jun-2012 | AN-No. 1GA59
Miloslav Macko 1MA196 1MA196, Forum, Instrument, Remote, Control, Python, R&S Forum, RS Forum, R&SForum, RSForum R&S®Forum for Instrument Remote Control Using R&S®Forum Application for Instrument Remote Control Miloslav Macko 1MA196 1MA196, Forum, Instrument, Remote, Control, Python, R&S Forum, RS Forum, R&SForum, RSForum R&S®Forum for Instrument Remote Control Related products
28-Jun-2018 | AN-No. 1MA196
This application note provides an application program for the audio analyzer R&S®UPV which calculates and displays the loudness of non-stationary sounds according to ISO 532-1 (Zwicker method). The theoretic background of the evaluation method is briefly explained.
14-Dec-2017 | AN-No. 1GA67
The application program of this application note provides a tool for cycling battery samples, using two-quadrant DC power supplies from Rohde & Schwarz. The batteries can be repeatedly charged and discharged while collecting information about open-circuit voltage, loaded voltage and internal resistance, depending on the charged and discharged capacity. The tool provides a variety of charts for displaying the collected data. It can be used for characterizing battery samples, as well as for creating battery models which can be used in the battery simulations of R&S®NGU201 and R&S®NGM200.This tool is meant for the use by knowledgeable experts. The application note does not provide instructions on how to properly charge and discharge batteries.
17-Dec-2021 | AN-No. 1GP130
This application note gives background information about the psychoacoustic measurements PESQ® (Perceptual Evaluation of Speech Quality) and PEAQ® (Perceptual Evaluation of Audio Quality). It also describes how to perform these measurements using the Rohde & Schwarz Audio Analyzer.
03-Apr-2009 | AN-No. 1GA49
Application program and documentation for averaging of 1/n octave spectra on the audio analyzer UPV.
19-Jul-2010 | AN-No. 1GA52
5G is the fifth generation of wireless communication technology supporting cellular networks. From GSM (2G) through to LTE (4G), each generation addresses technical challenges not overcome by its predecessor. As with previous generations, 5G requires new mobile devices and new base stations (BTS).Unlike previous generations, the use of radio beams in 5G requires completely new approaches with regard to the compliance, coverage, and quality of service testing.The new air interface is called 5G NR ("new radio"). This application note describes the measurement challenges of 5G NR and makes clear the benefits of using a monitoring receiver for measuring 5G signals.Real-world examples explain how to perform various key 5G measurements. The final section covers further 5G measurement possibilities using R&S products. "Over-the-air" (OTA) measurements are essential in 5G. This means staff from regulators and operators must work in unknown radio environments that vary according to location (e.g. urban or suburban) and mission (e.g. 5G BTS compliance testing or interference hunting). Measurement equipment must operate in a wide range of scenarios (close to the mast and far from the mast) and offer user-friendly functionality that enables the required measurements.Considering current global deployment trends, this paper focuses on the FR1 frequency band (sub 6 GHz).
07-Jun-2021 | AN-No. 1SL366
Applications requiring higher voltages or currents, or a stack of voltage sources with taps in-between, demand the combination of several DC power supply channels in series or in parallel.All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies.When a large number of power supply channels is used, it is desirable to have a tool for configuring all instruments and channels from one user interface, and for keeping an overview over the states and measurement values from all channels.The application program of this application note provides such a tool. The document contains background information and user manual for the software.
27-Aug-2020 | AN-No. 1GP127
This Application Note describes how the R&S® UPV and R&S® UPP200 audio analyzers can be used to replace the obsolete Agilent model 8903B audio analyzer in remote control applications.
24-Nov-2010 | AN-No. 1GA54
Most application notes for audio analyzer R&S® UPV include an application program which runs locally using the universal sequence controller option UPV-K1. This application note explains how sequence control programs can be modified to run on a remote PC using remote control option UPV-K4.
30-Jun-2012 | AN-No. 1GA60
This application note provides a tool for printing a report about measurement results on the audio analyzer R&S® UPV. The executable can be freely configured to include any result graphs and figures into the report. In addition it is an application example for a class library which can be included into custom application programs to add a printing function.
18-Jul-2011 | AN-No. 1GA57
This application note provides a program which allows to record total harmonic distortion, single harmonic distortion factors and level with one generator sweep. The executable may be installed and used without caring about programming. The source code is provided as basis for custom modifications.
16-Jul-2011 | AN-No. 1GA56
This application note provides an application program and instructions for performing speech quality tests and delay measurements in a live network, using the R&S®UPV audio analyzer.
14-Dec-2017 | AN-No. 1GA68
This paper reviews the classical spectrum analyzer measurement of L(f) and its shortcomings and discusses how modern phase noise test sets measure phase noise and avoid the limitations imposed by direct spectrum measurements.
31-Mar-2020
This application program supports the logging and fast logging functionality of the power supplies R&S® NGM200, NGU201 and NGU401. Standard logging is also supported with power supply R&S® NGL200 and NGP800. Power supplies R&S® NGA100 and NGE100 are supported in the data collection mode. Charting functionality is available for logged voltage, current and power values.
14-Nov-2019 | AN-No. 1GP122
This application note is about creating your own battery model for the R&S®NGM200 and R&S®NGU201, beyond the standard models provided within the battery simulation option NGM-K106 and NGU-K106. To get to a battery model, a few steps are required. To determine the parameters for the battery model, it is necessary to discharge a battery using a selected method, to record the data and to calculate the model on this basis. With this software, a connection can be established to the instrument, batteries can be measured using various measurement methods, and a model can then be created from these measurements. These models, which are determined from the measurements, can then be simulated with the power supply, thus creating a digital twin of the battery. Using these, test scenarios can be carried out in a safe and reproducible environment.
21-Nov-2022 | AN-No. 1GP136
All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies. In the case of parallel and serial connections it is usually desired to switch all channels simultaneously on and off for protecting the supplied circuitry and for avoiding overcurrent on other power supply channels.This application note describes how to connect and configure DC power supplies R&S®NGL200 and R&S®NGM200 for synchronized on and off switching of all channels across multiple power supplies.
15-Jun-2020 | AN-No. 1GP126
Play-only devices like CD- or MP3 players cannot be measured as traditional 4-pole devices. Therefore traditional transfer function measurements using the generator part of the audio analyzer are not possible. Those devices are tested with a pre-recorded test signal available as wav or MP3 file. This application note describes a fast test together with a setup and an executable which runs the test and displays the desired results. The test signal is provided as a linear coded wav file. This file can easily be coded into MP3 format using any commercially available or public domain wave editors or ripper programs. The test can also be executed by IEEE control and all results can be read out by IEEE commands.
28-Jun-2007 | AN-No. 1GA46
This application note proposes a digital level shifter for connecting the I2S interfaces R&S®UPP-B2 and R&S®UPV-B41 to devices under test with a logic voltage different from 3.3 V.
27-Mar-2020 | AN-No. 1GA71