A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
Firmware update via NRP
I am using the ultra segmentation mode to minimize the blind time. But this is not indicated. Is there a way to calculate it?
TM/RTA - Edge A/B Trigger - Remote commands for the trigger level
Some parts of my program cause timeouts. Is it possible to track the traffic via my VISA installation?
With version 1.7.20 we made changes to some parameters which lead to incompatibility with elder savesets.
I have several traces with markers in one channel. When I query the result of marker 1 I always get the response of trace 1. How can I get the result of marker 1 for trace 2?
Most accurate way to measure the length of a cable with a VNA
I do RMS measurement on a signal after switching the channels. Even with *OPC? or *WAI the result is implausible: 9.91e+37 . How can I get a correct result?
How can I generate, transfer and process an arbitrary waveform file for the HMF2550 using remote control? I found no command to load a wave form file from the USB stick.
Convert the trace data in a dataset file (*.SET) to a CSV file
Connecting power sensors
Initialize RF Generator, change start level for immunity testing using EMC32
I would like to be sure about the high impedance state of a dedicated channel for my power supply unit. Do you have a process to test and to ensure that? Can you also please explain, how the high impedance mode works?
I want to do a calibration with 75 Ohms at the ZNB/ZND/ZVA. Do these VNAs accept the auto cal unit ZV-Z53 with 75 Ohms impedance?
When looking at the data sheet of the LCX series I can not find any specifications concerning L and C. Where do I find these informations?
Transducer Factor: Transducer Factor for LISN?
Recover the Demodulated Data
Reading the magnitude (dB) and phase (degrees) values directly
FAQ; LabWindows/CVI 7.0 Bug
Calibrating a vector network analyzer (VNA) with different connectors on each port
FAQ: I have a portable license. Second installation on a device does not work.
Baud Rate Setting Resets After Power Line Disconnection
I want to perform a screenhsot on my FSH Spectrum Analyzer using a USB stick. Unfortunately all the pictures get saved to the \PUBLIC folder, but not to the USB stick.
Description of Antifreeze Mode in liquid cooled transmitters THx9
Reading *.spe files on a PC
EMC32-S: Amplifier properties, reverse coupling path attenuation
So far I only have experience how to add a transducer to a slidebar, a 2-Line-LISN or 4-Line LISN. Now, I want to add a transducer for an 8-Wire ISN (e.g. ENY81) to EMC32.
Distribution of accuracy HM8118
I want to save a reference waveform to file with remote commands. What is the correct SCPI sequence?