Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
735 Results
This application note describes DFS measurements with a spectrum analyzer. An external program, the DFS Analysis Tool, is used to improve measurement speed.
30-Mar-2007 | AN-No. 1EF59
The R&S®ELEKTRA EMC test software is a solution that controls complete EMC systems and automates measurements on equipment under test that is being tested for emissions and immunity compliance. It can be used to remotely control R&S®AdVISE, which is a visual inspection software to monitor up to 32 different Regions of Interest in one video for visible and audible changeThis Application Note describes how to set up R&S®ELEKTRA and R&S®AdVISE for remote testing.
23-Jul-2020 | AN-No. 1S005
When measuring audio components with unknown transients, the experienced engineer watches the settling of the DUT before accepting a measured result to be valid. The settling function in the UPL/UPD simulates this process and automates it by continuously comparing the measured value with a number of measured values stored before. A measured value is only accepted as being valid if it is within the tolerance limits entered by the user. This application note explains the settling process and gives hints for practical use.
03-Jun-1998 | AN-No. 1GA12
Short test times in conjunction with accurate and repeatable measurement results are essential when testing and calibrating mobile phones at board level. The R&S FSP Spectrum Analyzer offers wide dynamic range, stable and accurate results within shortest sweep time, making it the ideal choice for high-volume production testing. The utilisation of both the list mode feature and the marker list function for the Spectrum Analyzer R&S FSP, with its unsurpassed measurement speed via remote control are demonstrated in this application note.
29-Aug-2003 | AN-No. 1MA65
The R&S®QPS quick personnel security scanner transforms people-screening technology with its high-performance, fully electronic and solidstate flat panel design that has no moving parts. The R&S®QPS improves the security screening experience and operations by having a simple open design for a spacious screening environment and unobstructed view for security personnel, making high-resolution people screening more comfortable and efficient than ever before.
15-Apr-2019
Monitoring on up to 10 000 channels with different parameter settings
13-Jul-2012
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers. A single instrument, the R&S®ETL TV analyzer, performs all required ISDB-T transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.
13-May-2013 | AN-No. 7BM103
The R&S®SMW200A vector signal generator offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace signal generators, e.g. from other manufacturers, with the R&S®SMW200A without having to change the remote control code. This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
29-Apr-2016 | AN-No. 1GP110
This application note describes how to generate 3GPP (UTRA-FDD) signals for receiver tests under fading conditions for user equipment. The test setup requires an R&S®CMU200 Universal Radio Communication Tester with option R&S®CMU-B17 IQ-IF interface and an R&S®SMIQ Vector Signal Generator. The test setup can be calibrated with either a R&S®NRP-Zx USB power sensor or an NRP, NRVD, or NRVS Power Meter. To calibrate the baseband and RF path and configure performance tests according to the 3GPP test specification 34.121 easily, the program 3GFadLevCor is included.
01-Mar-2005 | AN-No. 1MA76
Reliable small cell planning is essential for important deployments like hospitals, manufacturing facilities, simply VIP (CxO) office floors or meeting rooms (the list of examples is endless). Often planning tools do not provide this high reliability and required accuracy.This application note is a simple step-by-step guide that introduces a practical method to perform reliable small cell planning.
09-Feb-2017 | AN-No. 1MA297
This application note describes the different memory types and locations that user information can be stored in a spectrum analyzer R&S® FSP, R&S® FSU or R&S® FSQ, as well as the different ways in which it can be erased/cleared for security reasons.
20-Sep-2004 | AN-No. 1EF53
The simulation of impulsive noise for tests on set-top boxes for digital TV (DTV) has so far been a highly complex task regarding the reproducibility of test signals. Using state-of-the-art technology from Rohde & Schwarz, this task can be accomplished with a simple test setup
07-Jul-2003 | AN-No. 7BM45
Level or power measurement of especially modulated signals using spectrum analyzers is becoming more and more important . Whereas the first choice in terms of accuracy for power measurement of any carrier (modulated or non-modulated) is a power meter, power measurement of spurious or in the adjacent channel of a transmission system needs a selective power meter with high dynamic range. A power meter, however, is a non-selective device with limited dynamic range and is not appropriate for these types of measurements. The first choice is a spectrum analyzer because of its versatile use as a general-purpose instrument. Compared to a power meter its power measurement accuracy is worse. In general this can be overcome by substitution methods using a power meter, an attenuator and a signal generator. But substitution is time-consuming and requires more investment in test equipment than a single instrument. Therefore it is most important to have a spectrum analyzer like the FSE, which can fulfill at least most of the requirements in terms of measurement accuracy.
13-Jan-1998 | AN-No. 1EF36
This Application Note gives 10 useful Tips & Tricks for the users of Rohde & Schwarz attribute-based instrument drivers. It is recommended for the first-time LabVIEW users as well as for the experienced programmers.
30-Jan-2017 | AN-No. 1MA228
Describtion and explanation of the MPEG and DVB-Standards and TV T&M
10-Dec-2011 | AN-No. 7BM_ADD01
This application note shows how to perform user equipment (UE) receiver tests, such as block error rate (BLER) and throughput tests, under fading conditions with the R&S®CMW500 RF tester and the R&S®SMW200A vector signal generator in LTE(-A), W-CDMA (HSPA+), TD-SCDMA, GSM (GRPS and EGPRS(2)), CDMA2000 and 1xEV-DO.
03-Nov-2015 | AN-No. 1MA194
As well as static tests, modern mobile communication standards also stipulate measurements under fading conditions, sometimes with additional white gaussian noise AWGN. Rohde & Schwarz supports these tests with the combination of the R&S®CMU200 Radio Communication Tester and the R&S®SMU200A or R&S®AMU200A Vector / Baseband Signal Generator and Fading Simulator. Applying fading and noise always raises the crest factor of a signal considerably. Thus, automatic path attenuation inside the Rohde & Schwarz baseband fader prevents the new signal peaks from being clipped at I/Q full scale. Any additional attenuation in the baseband, however, makes the RF output fall below its intended level. This application note shows how to achieve an accurate RF output level by compensating for the I/Q attenuation - without modifying the test setup or using additional instruments.
09-Jan-2009 | AN-No. 1MA135
With the R&S®RTO-K17/RTE-K17 High Definition Option the user will see more signal details with up to 16 bit vertical resolution.In combination with the superior analog front end of the R&S®RTO and R&S®RTE, the user has a versatile instrument in his hands to analyze a wide range of applications. From Switch Mode Power Supplies to Radar RF, the user can inspect all with one scope.
13-Apr-2015 | AN-No. 1TD06
The International Electrotechnical Commission (IEC) created the MBRAI specifications, which call for strict conformance tests that ensure the proper functionality of mobile receiver terminals for DVB-T/H transmissions. MBRAI is a common abbreviation of the IEC 62002 standard and stands for “mobile and portable DVB-T/H radio access interface”. This Application Note describes how the Broadcast Test System R&S®SFU provides all functions to generate MBRAI-compliant test signals. Only two special measurements require additional sources. For this purpose, the Test Transmitter R&S®SFE100 is used.
28-Nov-2007 | AN-No. 7BM61
This application note describes Methods of Implementation (MOI) for precise, fast, and error-free compliance testing of USB Type-C to legacy cable assemblies supporting USB3.1 Gen2, USB3.1 Gen1, and USB2.0. Based on 5 Gbps signaling per lane with vector network analyzers from Rohde & Schwarz.
18-Jan-2024 | AN-No. 1SL406
3-Port Adapter ZVR-B8 is an optional accessory to all Vector Network Analyzers of the ZVR family, namely ZVRL, ZVRE, and ZVR, and extends the two test ports PORT1 and PORT2 to a total of three test ports PORT1, PORT2 and PORT3. The option comprises an electronic single-pole double-throw switch (SPDT) by means of which PORT1 of the analyzer is switched to either PORT1 or PORT3 of 3-Port Adapter. Test port PORT2 of the analyzer is directly connected to PORT2 of the 3-Port Adapter and is not switched over.
04-Aug-1998 | AN-No. 1EZ26
This application note gives a short summary on how to use harmonic mixers in combination with Rohde & Schwarz Signal and Spectrum Analyzers. Focus of this application note is the use of conversion loss tables with different R&S analyzers. It also provides a tool to convert different formats of the conversion loss tables.
06-Aug-2010 | AN-No. 1EF75
This application note offers a straightforward description of how to analyze EMI problems using the Rohde & Schwarz Oscilloscopes. The discussion begins by covering the basic mechanisms that can result in unwanted RF emissions and then describes how to proceed in analyzing EMI problems. Finally, a practical example is given to illustrate the analysis process.
25-Jun-2014 | AN-No. 1TD05
Using the optional three-port or four-port adapter (ZVR-B8 and ZVR-B14), PORT 1 and PORT 2 of the network analyzers of the ZVR family (ZVRL, ZVRE and ZVR) can be expanded to up to four ports. Thus automatic measurements on three- and four-port DUTs can be easily performed without any reconnection of ports being required. With the electronic switches in the adapters, switchover between the various ports is fast to the extent that the known high measurement and display speed of the analyzers of the ZVR family is fully maintained.
04-Aug-1998 | AN-No. 1EZ37
This application note describes how to test audio amplifier audio characteristic using the audio analyzer R&S® UPV in accordance with standard IEC 60268-3. The test items include gain, frequency response, harmonic distortion, modulation distortion, difference-tone intermodulation, dynamic intermodulation distortion, noise and cross-talk. The test items are explained and the test steps are described in detail.
13-Feb-2008 | AN-No. RCS0704-0032
The purpose of the test setup described is to ensure or to enhance the level accuracy of signal generators or the generator part of communication testers. The level accuracy of test signals is particularly important at low levels when measuring BER level sensitivity at digital communication receivers. The highly linear FSP spectrum analyzer is used in combination with a power meter to get the best possible accuracy with high measurement speed over a very wide level range.
18-Feb-2011 | AN-No. 1MA21
Remote control of test and measurement equipment with a serial interface is limited to PC’s located in close proximity determined by the length of a typical serial cable connection (several feet). Usage of terminal server allows connecting through LAN or WAN networks thus controlling the instrument from further away even around the globe. The terminal server interfaces between TCP/IP protocol and the RS232 line. This application describes set-up of a popular terminal server from Black Box® Corporation to remotely and conveniently control the instruments EFA with EFA Scan software and DVRM or DVMD with Realtime Monitor / Stream Explorer software through a LAN or WAN network.
07-Jul-2003 | AN-No. 7BM41
An FSE Spectrum Analyser equipped with the Vector Signal Analysis option (FSE-B7) can measure oscillator settling time or transmitter attack and release times with high accuracy up to 40 GHz. No additional measurement equipment is needed.
12-Feb-1999 | AN-No. 1MA15
This Application Note describes two programs for calculating conversions: 1.: The Power Unit Calculator Power, dBm, dBmV and Volts @ 50 W 2.: The VSWR Calculator Reflection, VSWR, Return loss and Power reflection Reflections, Reflectionl to Mismatch Uncertainty.
03-Jul-1998 | AN-No. 1MA12