Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1118 Results
1TD04 1TD04, DC/DC, Oscilloscopes The objective of this paper is to evaluate the performance of a power supply using an oscilloscope. The main measurements taken are the input frequency, output voltage, output current, and the switching frequency. Initial Evaluation of a DC/DC Switch Mode Power Supply 1TD04 1TD04, DC/DC, Oscilloscopes The objective of this paper is to evaluate the performance of a
26-Nov-2013 | AN-No. 1TD04
Due to today’s worldwide highly competitive communications market, achieving shorter product design cycles, quicker response to customer requests and high-volume product runs at low costs is vital for manufacturers of wireless devices and components. These requirements inevitably lead to demands for improving the throughput of Automated Test Equipment (ATE) by increasing its speed. This application note describes in detail how the special features of the R&S® SMATE200A can be used to optimize speed and throughput in an automated test environment.
17-Apr-2007 | AN-No. 1GP63
Rohde & Schwarz offers unique one-box solutions for reliable testing of air navigation systems such as ILS, VOR and DME.
04-Nov-2010
This application note describes how to configure a Rohde & Schwarz Network Analyzer to make spectral measurements directly on a device under test.
16-Mar-2012 | AN-No. 1EZ62
- not available -
20-Jul-2001 | AN-No. 7BM25
Frequency Modulated Continuous Wave (FMCW) radar signals are often used in short range surveillance, altimeters and automotive radars. To ensure proper functionality, signal quality measures such as frequency linearity are of great importance.This application note focuses on fully automated, fast and accurate measurements, of linear FMCW radar signals. It explains the basic signal processing, the impact on radar key performance indicators in case of linearity deviations and explains test and measurement of linear FMCW signals in detail.Measurement of an FMCW radar signal in the 77-81 GHz band with 500 MHz of measurement bandwidth is demonstrated.
25-Apr-2014 | AN-No. 1EF88
This white paper describes the basic functionality of antennas. Starting with Hertz's Antenna model followed by a short introduction to the fundamentals of wave propagation, the important general characteristics of an antenna and its associated parameters are explained. A more detailed explanation of the functionality of some selected antenna types concludes this white paper.
04-Nov-2014 | AN-No. 8GE01
Determining the noise figure of a component can be difficult in unshielded lab environments. Measuring small noise figures (less than 3 dB) and reproducing the results is sometimes not possible. These difficulties are caused by interference effects (electric fields) that can occur in any environment. A suitable remedy is a measurement environment able to shield the Device Under Test (DUT) against all interfering fields in the range up to 3 GHz. When used in conjunction with a spectrum analyzer and Noise Measurement Software FS-K3, the Shielded Box ZA-SB10 provides a complete noise measurement system.
16-Oct-2002 | AN-No. RSH01
Coaxial connectors are a key component in RF and microwave applications. Their importance and contribution to overall system performance is sometimes overlooked. This application note focuses on coaxial connectors found in RF and microwave applications, providing general information on the available types; how to take care of connectors and connector electrical properties. This information is essential for anyone specifying and using Rohde and Schwarz test and measurement equipment and will help with the selection of the correct types of coaxial connector, handling connectors to obtain accurate and repeatable measurements, and to maximize the longevity and performance of coaxial connectors.
09-Apr-2015 | AN-No. 1MA99
A new calibration method, presented by John R. Juroshek (NIST), offers fast and accurate determination of the equivalent source match of three-port devices like power-splitters and directional-couplers. The measurement result is directly displayed as normal trace on the R&S ZVM or R&S ZVK and can be stored in the most common data-formats for further processing and documentation.
13-Dec-2002 | AN-No. 1EZ51
White noise of a defined power is superimposed on the DVB signal. From the noise and the modulated DVB signal, the S/N respectively the C/N ratio in dB (with consideration of the 'roll off' factor) can be calculated. After conversion, the corresponding BER is obtained for each S/N value.
08-May-2002 | AN-No. 7BM03
- not available -
05-Aug-2010 | AN-No. 7BM26
Due to the fact that Microsoft does not maintain the Visual Studio .NET 2003 anymore Rohde & Schwarz has to use the successor compiler product Visual Studio .NET 2005 for building the test case packages. All CRTU-G customers having proprietary test case packages, developed based on Visual Studio .NET 2003, can migrate them to Visual Studio .NET 2005. This is required when the proprietary test case packages are going to be enhanced on a platform with installed Visual Studio .NET 2005.
28-Nov-2007 | AN-No. 1CM63
Most of the tests specified in the 3GPP standard TS 34.121 [1] Release 6 (Rel-6) can be performed with the R&S®CMW500. This document provides a step-by-step guide on how to use a stand-alone R&S®CMW500 to take Rel-6 measurements on transmitter characteristics and execute performance tests according to TS 34.121 V9.7.0, clauses 5 and 10. Test cases that require fading simulation can also be carried out with the aid of a standalone R&S®CMW500 that has been configured with a built-in fading simulator option. That greatly reduces test setup complexity. Furthermore, the R&S®CMW500's wizard enables easy configuration of the test setup for various HSUPA subtests as specified by TS34.121 [1]. The procedure detailing how the wizard is used is also explained for each test case. The test cases mentioned in this application note are carried out using Rel-6 user equipment (UE) that supports Operating Band I and Power Class 3.
27-Nov-2013 | AN-No. 1CM97
The need for an objective evaluation of mobile network quality and performance drives two fundamentally different approaches, crowdsourcing and mobile network testing. The crowdsourcing market is highly saturated. More than 20 companies have a significant focus on crowdsourcing mobile network measurements. To get measurement results, they use different concepts that serve different purposes. This application card describes the structure of the crowdsourcing space and analyzes the pros and cons of both approaches.
06-Oct-2022
When monitoring transmission systems it is often necessary to control the monitoring equipment and to check the measurement results from a remote station. The user may also be interested to know which transmission data cause an error or violate a standard. Rohde & Schwarz offers several instruments that meet all these requirements in the field of digital TV transmission. This application note gives an overview of the design and use of a DTV monitoring system made up of the above-mentioned instruments and meeting the requirements.
15-Feb-2002 | AN-No. 7BM38
In frequent cases, it appears that the MPEG2 decoder is not located in the control/monitoring room. The present application note describes how to operate a remote control of up to four DVMDs over an ethernet link.
31-Mar-1999 | AN-No. 7BM01
The high-definition multimedia interface (HDMI™) is used to transmit audio and video data. HDMI has become the standard for a variety of consumer electronic products, such as Blu-ray™ players, A/V receivers, set-top box, TV monitors and digital video/ still cameras. The HDMI interface measurements needed for these products require specialized T&M equipment. This equipment is not only needed for certification, but is also used for a variety of tests during development, for quality assurance and for end-of-line production testing. The R&S®VTC, R&S®VTE and R&S®VTS video testers from Rohde & Schwarz make it possible to test A/V interfaces such as HDMI easily, reliably and cost efficiently. This application note focuses on functional testing and debugging of HDMI interfaces using the R&S®VTC/VTE/VTS. It explains how these instruments can be used to assess the HDCP implementation, the ARC or the CEC functionality.
04-Jun-2014 | AN-No. 7BM85
The terrestrial television standard DVB T2 is gaining in significance as a result of the growing scarcity of available frequencies. New systems are being tested in many countries around the world. Other countries have already completed the introductory phase for DVB T2. Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers or even disrupt adjacent channels.A single instrument, the R&S®ETL TV analyzer, performs all required DVB-T2 transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.The measurements described here satisfy many country-specific and customer-specific test specifications. Users need only set the limit values accordingly.
24-Jul-2014 | AN-No. 7BM106
While RF communication signal distortions in nonlinear transmission paths have been predicted theoretically and studied experimentally for various signals, it is interesting to examine a wideband nonlinear system reaction to a wideband 3G signal and a narrowband 2G signal. Research and testing have demonstrated that, while most vital signal parameters remain within the limits specified by applicable standards even if composite signal power approaches specified maximum power, a relatively high level of spurious emissions caused by cross- and intermodulation can result. To avoid degrading both existing and new systems, this and other signal quality issues must be considered when designing and deploying multitechnology systems.
03-Nov-2006 | AN-No. 1MA110
3GPP TS25.141 defines conformance tests for UTRA base stations (NodeB). This application note describes how performance tests (TS25.141 Chapter 8) can be performed quickly and easily by using vector signal generators from Rohde & Schwarz. Examples illustrate the manual operation. A free software program enables and demonstrates remote operation.
04-Mar-2015 | AN-No. 1MA78
Especially with test receivers not comprising a built-in disk drive (ESHS10, ESVS10, ESVD, ESVB and ESPC) it is necessary to store instrument settings before a firmware update or before changing the battery of the static memory to be able to restore the settings later on. Frequently it is desirable to exchange settings or comprehensive data like transducer sets between receivers, or receivers have to be set up to suit different applications.
18-Jan-2002 | AN-No. 1EE20
TeleZüri, Switzerland’s most successful regional TV station, has switched from tape-based operations to file-based workflows. At the same time, TeleZüri was introducing HD as standard resolution in its workflows.
18-Nov-2014
This application note discusses WLAN standard IEEE 802.11n. It first describes the most important amendments to previous releases and the ambitious new measurement tasks. Then, it describes how to deal with these tasks using Rohde & Schwarz instruments. The main focus here is on transmission over several TX and RX antennas (MIMO). Building multistandard signals using Rohde & Schwarz generators is also described. Screenshots from the analyzer taken on 802.11n signals complete the document.
26-Apr-2013 | AN-No. 1MA179
The duration of a measurement in multi evaluation list mode is sensitive to the test setup. This document describes various methods to achieve optimized performance for such measurements. The availability of the methods depends on the CMW500 version.
17-Jul-2012 | AN-No. 1CM100
Volker Fischer 1EF86 LTE, MIMO, LTE-MIMO, RTO1044, SMU200A, K102, K103, K102PC, K103PC This application note describes the possibilities to measure LTE MIMO with the LTE-Software R&S®FS-K102/K103PC in combination with an R&S®RTO1044 oscilloscope. Testing LTE MIMO Signals using a R&S®RTO Oscilloscope Volker Fischer 1EF86 LTE, MIMO, LTE-MIMO, RTO1044, SMU200A, K102, K103, K102PC, K103PC This application
24-Apr-2013 | AN-No. 1EF86
This application note describes how to configure the signal source analyzer R&S FSUP for highest dynamic range phase noise measurement in the microwave frequency range up to 50 GHz. It compares performance in terms of phase noise sensitivity using an additional internal down converter versus an external down converter or a frequency divider. Both methods are described and differences are shown.
18-Feb-2009 | AN-No. 1EF68