FPL Spectrum analyzer

High performance wherever you are

FPL Spectrum analyzer
Open Lightbox
FPL Spectrum analyzer
Open Lightbox
FPL Spectrum analyzer
Open Lightbox
FPL Spectrum analyzer
Open Lightbox
FPL Spectrum analyzer
Open Lightbox
FPL Spectrum analyzer
Open Lightbox
FPL Spectrum analyzer
Open Lightbox
R&S®FPL1000 spectrum analyzer, front low R&S®FPL1000 spectrum analyzer, front low R&S®FPL1000 spectrum analyzer, hero view R&S®FPL1000 spectrum analyzer, side view R&S®FPL1000 spectrum analyzer, front low R&S®FPL1000 spectrum analyzer, front low R&S®FPL1000 spectrum analyzer, back low

Key facts

  • Frequency range 5 kHz to 26.5 GHz
  • SSB phase noise: typ. –108 dBc (1 Hz) at 10 kHz 
  • DANL with preamplifier: typ. –163 dBm from 10 MHz to 2 GHz
  • Lightweight with small footprint
  • 40 MHz analysis bandwidth (option)

Brief description

In RF labs, FPL instruments are indispensable oscilloscopes or multimeters. A single instrument can perform many measurement tasks. FPL analyzers can be used for spectrum analysis, highly accurate power measurements for power sensors and analysis of analog and digitally modulated signals.

Features & benefits

One instrument for multiple applications

A single instrument for a wide variety of measurements
 

The FPL can be used for spectral measurements, high accuracy power measurements with power sensors and analyzing analog and digitally modulated signals.

Measurement modes
Open Lightbox

Measurement modes

The standard FPL base unit supports various advanced spectrum measurement modes

Solid RF performance

Low phase noise and low displayed average noise level
 

Featuring a phase noise of typ. –108 dBc (1 Hz) at 10 kHz offset (1 GHz carrier), a third-order intercept point of typ. +20 dBm, 1 Hz to 10 MHz resolution bandwidth and typ. The FPL is comparable to higher class analyzers with –163 dBm displayed average noise level. It is ideal for the lab, production and service.

Phase noise measurement
Open Lightbox

Phase noise measurement

Simple phase noise measurement with a marker function

Intuitive user interface

As intuitive as a smartphone
 

The touchscreen can be used to configure and perform measurements. A one-finger swipe across the screen adjusts the center frequency or the reference level. A two-finger swipe can adjust the displayed span or level range.

Multiview of the R&S®FPL1000
Open Lightbox

Multiview of the R&S®FPL1000

The sequencer can perform spectrum measurements, adjacent channel power measurements, time domain measurements and spectrogram measurements

Fully portable

It can be used almost everywhere…
 

The low-weight optional battery pack weighs just 6 kg and can last for three hours of operation together with the carrying bag and shoulder harness let you use the FPL spectrum analyzer from anywhere.

Carrying bag for the FPL1000
Open Lightbox

Carrying bag for the FPL1000

Optional FPL1 carrying bag. The R&S®FPL1-B31 battery option allows operation while inside the bag.

Available models

Available models
Models
Frequency range
Phase noise
DANL @ 1 GHz
Max. analysis bandwidth
Instrument type

R&S®FPL1003

Order number 1304.0004.03

Click on order no. to copy
Order number 1304.0004.03 is now copied to your clipboard.
Frequency range
5 kHz - 3 GHz
Phase noise
< –108 dBc (1 Hz)
(f = 1 GHz, 10 kHz offset)
DANL @ 1 GHz
< –163 dBm/Hz
Max. analysis bandwidth
40 MHz (FPL1-B40)
Instrument type
Signal and spectrum analyzer

R&S®FPL1007

Order number 1304.0004.07

Click on order no. to copy
Order number 1304.0004.07 is now copied to your clipboard.
Frequency range
5 kHz - 7.5 GHz
Phase noise
< –108 dBc (1 Hz)
(f = 1 GHz, 10 kHz offset)
DANL @ 1 GHz
< –163 dBm/Hz
Max. analysis bandwidth
40 MHz (FPL1-B40)
Instrument type
Signal and spectrum analyzer

R&S®FPL1014

Order number 1304.0004.14

Click on order no. to copy
Order number 1304.0004.14 is now copied to your clipboard.
Frequency range
5 kHz - 14 GHz
Phase noise
< -108 dBc (1 Hz)
(f=1 Ghz, 10 kHz offset)
DANL @ 1 GHz
< -160 dBm/Hz Pre-amp on
Max. analysis bandwidth
40 MHz (FPL1-B40, and FPL1-B11)
Instrument type
Signal and spectrum analyzer

R&S®FPL1026

Order number 1304.0004.26

Click on order no. to copy
Order number 1304.0004.26 is now copied to your clipboard.
Frequency range
5 kHz - 26.5 GHz
Phase noise
<-108 dBc (1 Hz)
(f=1 GHz, 10 kHz offset)
DANL @ 1 GHz
<-160 dBm/Hz Pre-amp on
Max. analysis bandwidth
40 MHz (FPL1-B40, and FPL1-B11)
Instrument type
Signal and spectrum analyzer

Available options

Hardware options
Product
Description
R&S®FPL1-B4

Order number 1323.1902.02

Click on order no. to copy
Order number 1323.1902.02 is now copied to your clipboard.
Description

OCXO accurate reference frequency

High precision frequency reference

R&S®FPL1-B5

Order number 1323.1883.02

Click on order no. to copy
Order number 1323.1883.02 is now copied to your clipboard.
Description

Additional interfaces

Video out, IF out, noise source control, AUX port, connector for R&S®NRP power sensors

R&S®FPL1-B9

Order number 1323.1925.03

Click on order no. to copy
Order number 1323.1925.03 is now copied to your clipboard.
Description

Internal generator up to 3 GHz 

R&S®FPL1-B9

Order number 1323.1925.07

Click on order no. to copy
Order number 1323.1925.07 is now copied to your clipboard.
Description

Internal generator for 7/14/26.5 GHz

R&S®FPL1-B10

Order number 1323.1890.02

Click on order no. to copy
Order number 1323.1890.02 is now copied to your clipboard.
Description

GPIB interface

Additional interface for remote control by GPIB, plug-in unit

R&S®FPL1-B11

Order number 1323.1619.02

Click on order no. to copy
Order number 1323.1619.02 is now copied to your clipboard.
Description

YIG preselector bypass

Enables full 40 MHz bandwidth analysis in frequencies up to 26.5 GHz

R&S®FPL1-B12

Order number 1353.6660.02

Click on order no. to copy
Order number 1353.6660.02 is now copied to your clipboard.
Description

External generator control

R&S®FPL1-B19

Order number 1304.0427.02

Click on order no. to copy
Order number 1304.0427.02 is now copied to your clipboard.
Description

Second hard disk (SSD)

(mounted on PC board)

R&S®FPL1-B22

Order number 1323.1719.02

Click on order no. to copy
Order number 1323.1719.02 is now copied to your clipboard.
Description

RF preamplifier for 3/7.5 GHz.

R&S®FPL1-B22

Order number 1323.1702.02

Click on order no. to copy
Order number 1323.1702.02 is now copied to your clipboard.
Description

RF Preamplifier 14 GHz

R&S®FPL1-B22

Order number 1323.1777.02

Click on order no. to copy
Order number 1323.1777.02 is now copied to your clipboard.
Description

RF Amplifier 26.5 GHz

R&S®FPL1-B25

Order number 1323.1990.02

Click on order no. to copy
Order number 1323.1990.02 is now copied to your clipboard.
Description

1 dB Steps for electronic attenuator

R&S®FPL1-B30

Order number 1323.1877.02

Click on order no. to copy
Order number 1323.1877.02 is now copied to your clipboard.
Description

DC Power supply for 12/24 V supply

R&S®FPL1-B31

Order number 1323.1725.02

Click on order no. to copy
Order number 1323.1725.02 is now copied to your clipboard.
Description

Li-Ion battery pack

R&S®FPL1-B40

Order number 1323.1931.02

Click on order no. to copy
Order number 1323.1931.02 is now copied to your clipboard.
Description

40 MHz analysis bandwidth

Enables the use of 40 MHz bandwidth for R&S®ZNLx-B1 spectrum analysis option

Measurement application options
Product
Description
R&S®FPL1-K7

Order number 1323.1731.02

Click on order no. to copy
Order number 1323.1731.02 is now copied to your clipboard.
Description

AM/FM/PM analog modulation analysis

Modulation analysis for analog (AM, FM, PM) modulated single carrier signals
(for use with the R&S®ZNL, the R&S®ZNLx-B1 is required )

R&S®FPL1-K9

Order number 1323.1754.02

Click on order no. to copy
Order number 1323.1754.02 is now copied to your clipboard.
Description

Measurements with R&S®NRP power sensors

Supports R&S®NRP power sensors for power measurements.
(For use with the R&S®ZNL, the R&S®ZNLx-B1 is required )

R&S®FPL1-K40

Order number 1323.1831.02

Click on order no. to copy
Order number 1323.1831.02 is now copied to your clipboard.
Description

Phase noise measurement application

Order number 1323.1783.02

Click on order no. to copy
Order number 1323.1783.02 is now copied to your clipboard.
Description

EMI measurement application

Finding, classifying and eliminating electromagnetic interference

R&S®FPL1-K70

Order number 1323.1748.02

Click on order no. to copy
Order number 1323.1748.02 is now copied to your clipboard.
Description

Vector signal analysis

The R&S®FPL1-K70 vector signal analysis option is a powerful tool for analyzing individual digitally modulated signals down to the bit level.

R&S®FPL1-K70M

Order number 1323.1625.02

Click on order no. to copy
Order number 1323.1625.02 is now copied to your clipboard.
Description

Multi-modulation analysis

The R&S®FPL1-K70M multicarrier modulation analysis application (R&S®FPL1-K70 option required) allows DVB‑S2X signals to be analyzed.

R&S®FPL1-K70P

Order number 1323.1631.02

Click on order no. to copy
Order number 1323.1631.02 is now copied to your clipboard.
Description

BER measurements with PRBS data

The R&S®FPL1-K70P is an extension of the R&S®FPL1-K70 vector signal analysis option that allows the measurement of raw bit error rate (BER) on PRBS data up to PRBS23.

PC software
Product
Description

Order number 1345.1011.06

Click on order no. to copy
Order number 1345.1011.06 is now copied to your clipboard.
Description

Software

Brings the experience and power of Rohde & Schwarz signal analysis to PC and cloud

R&S®VSE-K70

Order number 1320.7522.06

Click on order no. to copy
Order number 1320.7522.06 is now copied to your clipboard.
Description

Vector signal analysis

R&S®VSE-K106

Order number 1320.7900.06

Click on order no. to copy
Order number 1320.7900.06 is now copied to your clipboard.
Description

EUTRA/LTE

Narrowband IoT analysis

Order number 1345.1105.06

Click on order no. to copy
Order number 1345.1105.06 is now copied to your clipboard.
Description

R&S®VSE-K7

Order number 1320.7539.06

Click on order no. to copy
Order number 1320.7539.06 is now copied to your clipboard.
Description

Analog modulation analysis (AM/FM/φM)

Modulation analysis for AM/FM/φM modulated single carriers

R&S®VSE-K10

Order number 1320.7574.06

Click on order no. to copy
Order number 1320.7574.06 is now copied to your clipboard.
Description

GSM measurements

GSM/EDGE/ EDGE Evolution

R&S®VSE-K60

Order number 1320.7868.06

Click on order no. to copy
Order number 1320.7868.06 is now copied to your clipboard.
Description

Transient measurements

Transient analysis

R&S®VSE-K60C

Order number 1320.7874.06

Click on order no. to copy
Order number 1320.7874.06 is now copied to your clipboard.
Description

Transient chirp measurements

Transient analysis, requires R&S®VSE-K60

R&S®VSE-K60H

Order number 1320.7880.06

Click on order no. to copy
Order number 1320.7880.06 is now copied to your clipboard.
Description

Transient hop measurements

Transient analysis, requires R&S®VSE-K60

R&S®VSE-K96

Order number 1320.7922.06

Click on order no. to copy
Order number 1320.7922.06 is now copied to your clipboard.
Description

OFDM signal analysis

R&S®VSE-K100

Order number 1320.7545.06

Click on order no. to copy
Order number 1320.7545.06 is now copied to your clipboard.
Description

EUTRA/LTE FDD uplink and downlink measurement application

LTE signal analysis

R&S®VSE-K102

Order number 1320.7551.06

Click on order no. to copy
Order number 1320.7551.06 is now copied to your clipboard.
Description

EUTRA/LTE advanced and MIMO (downlink)

LTE signal analysis

R&S®VSE-K104

Order number 1320.7568.06

Click on order no. to copy
Order number 1320.7568.06 is now copied to your clipboard.
Description

EUTRA/LTE TDD uplink and downlink measurement application

LTE signal analysis

Noise sources
Product
Description

Order number 1338.8008.18

Click on order no. to copy
Order number 1338.8008.18 is now copied to your clipboard.
Description

Smart noise source 10 MHz to 18 GHz

Order number 1338.8008.26

Click on order no. to copy
Order number 1338.8008.26 is now copied to your clipboard.
Description

Smart noise source 10 MHz to 26.5 GHz

General
Product
Description
R&S®FPL1-Z1

Order number 1323.1960.02

Click on order no. to copy
Order number 1323.1960.02 is now copied to your clipboard.
Description

Protective hard cover

R&S®FPL1-Z2

Order number 1323.1977.02

Click on order no. to copy
Order number 1323.1977.02 is now copied to your clipboard.
Description

Transport bag, transparent cover

R&S®FPL1-Z3

Order number 1323.1683.02

Click on order no. to copy
Order number 1323.1683.02 is now copied to your clipboard.
Description

Carrying vest holster

R&S®FPL1-Z4

Order number 1323.1677.02

Click on order no. to copy
Order number 1323.1677.02 is now copied to your clipboard.
Description

Spare battery pack

R&S®FPL1-Z6

Order number 1323.1954.02

Click on order no. to copy
Order number 1323.1954.02 is now copied to your clipboard.
Description

Rack mount kit (RAL5014 pigeon blue)

R&S®FPL1-Z6B

Order number 1323.1954.03

Click on order no. to copy
Order number 1323.1954.03 is now copied to your clipboard.
Description

Rack mount kit (RAL5000 violet blue)

R&S®FPL1-Z7

Order number 1353.6648.02

Click on order no. to copy
Order number 1353.6648.02 is now copied to your clipboard.
Description

D-Sub cable for TTL-synchronization

Instrument security
Product
Description
R&S®FPL1-K33

Order number 1323.1290.02

Click on order no. to copy
Order number 1323.1290.02 is now copied to your clipboard.
Description

Security write protection for solid-state drive

Application videos

Spectrum analyzers – Designed for you. Not for the hype

Benchtop essentials that combine quality and versatility at a great price. Such fun!

29-Aug-2024

Spectrum & Vector network analyzer promotion

Spectrum & Vector network analyzer promotion

Widest variety of fully equipped products up to 36% off.

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.