Key facts
- Bandwidth: 200 MHz to 1 GHz
- Sample rate: up to 5 Gsample/s
- Memory depth: up to 1 Gsample
- ADC resolution: 10-bit
- Display: 10.1’’ capacitive touchscreen
Starting at USD 7,420
Key facts
Starting at USD 7,420
Designed with top class signal integrity and responsive ultra-deep memory, the R&S®RTA4000 brings the power of 10 to a new level. The Rohde & Schwarz designed 10-bit ADC plus best-in-class noise and memory depth for sharp waveforms, more accurate measurements and confidence when faced with unexpected measurement challenges.
Quick links
See small signal details in the presence of large signals
The R&S®RTA4000 has a customized Rohde & Schwarz 10-bit A/D converter and is a four-fold improvement over conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltage across the switching device must be determined during the on/off times within the same acquisition.
100 Mpoint standard and 200 Mpoint interleaved
The R&S®RTA4000 has top-class memory depth of 100 Mpoints per channel and 200 Mpoint in interleaved mode. This is ten times more than similar oscilloscopes in the same instrument class. Users can capture longer acquisition sequences even at high sampling rates for more analysis results, such as when examining transients in switched-mode power supplies.
Segmented memory: 1000 Mpoint with history function
The R&S®RTA-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. The variable segment sizes enable optimal utilization of the 1000 Mpoint memory. In history mode, previous acquisitions in the maximum segmented memory depth of 1000 Mpoint can be used for further analysis.
16 additional digital channels
The R&S®RTA-B1 option turns every R&S®RTA4000 into an intuitive MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from the analog and digital components of an embedded design - synchronized and time correlated to each other. The delay between A/D converter input and output can be conveniently determined with cursor measurements.
Generate analog and digital stimuli
The R&S®RTA-B6 waveform and pattern generator for up to 50 Mbit/s can be used in educational settings and prototype hardware implementation. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns include. I2C, SPI, UART and CAN/LIN.
Measure and display electrical potential
The R&S®RTA4000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Standard measurement functions include DC, AC+DC (RMS) and AC (RMS).
Difficult-to-find faults often result from the interaction between time and frequency signals. The R&S®RTA4000 FFT function is activated at the push of a button or by simply entering the center frequency and span. The high-performance FFT function in the R&S®RTA4000 oscilloscope can be used to analyze signals with up to 128k points. Other practical tools include cursor measurements and autoset in frequency domain.
Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. Masks assess the quality and stability of a DUT based on statistical pass/fail evaluations. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation generates a pulse output at the AUX-OUT connector on the R&S®RTA4000. This pulse output can be used to trigger actions in the measurement setup.
See power signal details with up to 10-bit resolution
Even the smallest details of a high dynamic signal are important to power measurements. RDS (on) verification for a MOSFET is one example. The high ADC resolution of R&S®RTA4000 oscilloscopes increases vertical resolution up to 10 bits. Previously unseen signal details are revealed and measurable. The RDS(on) example shows how the slope of the drain-to-source-voltage can be measured while the switch is closed.
Order number 1335.7700P04
Order number 1335.7700P34
Order number 1335.7700P54
Order number 1335.7700P64
Vertical system | ||
Analog channels | 4 | |
Digital channels (opt.) | 16 | |
Bandwidth (-3 dB) | R&S®RTA4004 (with R&S®RTA-B24x options) | 200 MHz, 350 MHz, 500 MHz, 1 GHz |
Rise time | R&S®RTA4004 (with R&S®RTA-B24x options) | 1.75 ns, 1 ns, 700 ps, 350 ps |
Input impedance | 50 Ω ± 1,5% (meas.), 1 MΩ ± 1 % (meas.) || 14 pF ± 1 pF (meas.) | |
Input sensitivity | max. bandwidth in all range | at 1 MΩ: 500 μV/div to 10 V/div at 50 Ω: 500 μV/div to 1 V/div |
ADC resolution | 10 bit, up to 16 bit with high resolution decimation | |
DC gain accuracy | offset and position = 0, maximum operating temperature change of ±5°C after self-alignment | input sensitivity > 5 mV/div: ±1 % of full scale input sensitivity ≤ 5 mV/div to ≥ 1 mV/div: ±1.5 % of full scale input sensitivity < 1 mV/div: ±2.5 % of full scale |
Acquisition system | ||
Real-time sampling rate | 2.5 Gsample/s; 5 Gsample/s, interleaved | |
Acquisition memory | 100 Mpoint (200 Mpoint, interleaved); 1 Gsample segmented memory |
|
Max. acquisition rate | 64 000 waveforms/s (2 000 000 in fast segmented memory mode) |
|
Horizontal system | ||
Timebase range | selectable between 0.5 ns/div and 500 s/div | |
Accuracy (after delivery/calibration) | ±0.5 ppm | |
Channel-to-channel skew | < 200 ps (meas.) | |
Channel deskew | ±500 ns | |
Trigger system | ||
Standard trigger types | edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus | |
Optional trigger types | I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN, audio (I2S),ARINC 429, MIL-STD-1553 | |
Trigger sensitivity | with DC, AC, LF reject, noise reject 1 GHz, 500 MHz, 350 MHz > 2.2 mVpp input sensitivity + 1 div (nom.) (input sensitivity: [mV/div]) 200 MHz, 100 MHz > 1.5 mVpp input sensitivity + 0.8 div (nom.) (input sensitivity: [mV/div]) 20 MHz > 0.6 mVpp input sensitivity + 0.4 div (nom.) (input sensitivity: [mV/div]) with HF reject all input sensitivities 1 div (meas.) | |
Analysis and measurement functions | ||
Automatic measurements | 32 | |
Cursor measurements | 4 | |
Waveform mathematics | Five equations math-on-math functions (addition, subtraction, multiplication, division, square, square root, abs. value, reciprocal, inverse, common log,, natural log., derivative, integral, low pass, high pass, track unipolar + bipolar on period, frequency, pulse width, duty cycle) | |
Mask testing | ||
Mask definition | elementary (tolerance mask around the signal) | |
History and segmented memory | ||
Number of segments | up to 87 380 | |
Protocol trigger and decode | ||
Supported protocols | I2C, SPI, UART/RS-232/RS-422/RS-485, CAN, LIN, I2S, MIL-STD-1553, ARINC429 | |
Waveform generator | ||
Resolution | 14 bit | |
Sample rate | 250 Mpoint/s | |
Amplitude | high Z; 50 Ω | 20 mV to 10 V (Vpp); 10 mV to 5 V (Vpp) |
DC offset | high Z; 50 Ω | ±5 V; ±2.5 V |
Arbitrary | max. 10 Mpoint/s; 32k point | |
Logic analyzer (MSO) functionality | ||
Digital input channels | 16 | |
MSO memory depth | two logic probes: 100 Mpoint for every channel one logic probe: 200 Mpoint for every channel |
|
MSO Bandwidth | 400 MHz (meas.) | |
MSO sampling rate | 2.5 Gsample/s; 5 Gsample/s, interleaved | |
MSO input impedance | 100 kΩ ± 2 % || ~4 pF (meas.) at probe tips | |
Parallel buses | up to 4 | |
General data | ||
Dimensions | W × H × D | 390 mm × 220 mm × 152 mm (15.4 in × 8.66 in × 5.98 in) |
Weight | 3.3 kg (7.3 lb) | |
Display | 10.1" WXGA TFT color display (1280 × 800 pixel) | |
Interfaces | USB host with MTP, USB device, LAN, powerful web server for remote display and operation | |
Operating system | Embedded |
Order number 1335.7823.02
Mixed signal option: 400 MHz
Turns R&S®RTA4000 oscilloscopes into fast, precise and easy-to-use mixed signal oscilloscopes (MSO).
Order number 1335.7830.02
Arbitrary waveform generator
Adds a 25 MHz signal generator and a 4-bit pattern generator to your R&S®RTA4000 oscilloscopes.
Order number 1335.7846.02
Bandwidth upgrade of the R&S®RTA4004 to 350 MHz bandwidth
Order number 1335.7852.02
Bandwidth upgrade of the R&S®RTA4004 to 500 MHz bandwidth
Order number 1335.7869.02
Bandwidth upgrade of the R&S®RTA4004 to 1 GHz bandwidth
Order number 1335.7681.02
I²C/SPI serial triggering and decoding
Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses
Order number 1335.7698.02
UART/RS-232/RS-422/RS-485 serial triggering and decoding
Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses
Order number 1335.7717.02
CAN/LIN serial triggering and decoding
Triggering and decoding of CAN and LIN interfaces
Order number 1335.7723.02
I²S/LJ/RJ/TDM triggering and decoding
Triggering and decoding of I²S buses
Order number 1335.7730.02
MIL-1553 serial triggering and decoding
Triggering and decoding of MIL-STD-1553 buses
Order number 1335.7746.02
ARINC 429 serial triggering and decoding
Triggering and decoding of ARINC 429 buses
Order number 1335.7769.02
Power analysis
When analyzing power electronics, the input and output and the internal transfer function of the component have to be characterized. The power analysis option provides the necessary measurement functions, including inrush current, output spectrum and safe operating area (SOA).
Order number 1335.7975.02
Frequency Response Analysis (Bode plot)
The R&S®RTA-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio.
Order number 1335.7981.02
Spectrum analysis and spectrogram
The spectrum analysis option enhances the powerful FFT capability of R&S®RTA4000 oscilloscopes with spectrogram display.
Order number 1333.1728.02
Front cover
Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000
Order number 1333.1734.02
Soft bag
Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories
Order number 1335.9290.02
Transit case with wheels for R&S®RTB
Order number 1335.7875.02
Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes
Order number 1338.0007.02
Probe adapter
Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface
Order number 1333.1711.02
19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU
Order number 1333.2401.02
Passive probe, 500 MHz, 10:1
Order number 1409.7550.00
Passive probe, 500 MHz, 10:1
Order number 1333.1370.02
Passive probe, 38 MHz, 1:1
Order number 1418.7007.02
Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface
Order number 1410.4080.02
Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Order number 1410.3502.02
Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Order number 1410.4715.02
Active differential probe, 1 GHz, Rohde & Schwarz probe interface
Order number 1410.4409.02
Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface
Order number 1800.5006.02
Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
2.0 GHz, 1:1, 50 kΩ, R&S probe interface
Order number 1333.0873.02
250 MHz passive high voltage probe
Order number 1409.7720.02
400 MHz passive high voltage probe
Order number 1409.7737.02
400 MHz passive high voltage probe
Order number 1800.2307.02
200 MHz High voltage differential probe
Order number 1800.2107.02
100 MHz High voltage differential probe
Order number 1800.2207.02
200 MHz High voltage differential probe
Order number 1800.2007.02
100 MHz High voltage differential probe
Order number 1333.0850.02
AC/DC 20 kHz current probe
Order number 1333.0844.02
100 kHz current probe
Order number 1409.8204.02
2 MHZ current probe
Order number 1409.7750K02
10 MHZ current probe
Order number 1409.8210.02
10 MHZ Current probe
Order number 1409.7766K02
100 MHZ current probe
Order number 1409.8233.02
100 MHZ current probe
Order number 1409.7772K02
120 MHz current probe
Order number 1801.4932.02
120 MHz current probe
Order number 1147.2736.02
E and H near-field probe set
Order number 1333.0721.02
400 MHz logic probe
Order number 1409.7789.02
Power supply for probes
Power supply for R&S®RT-ZC10/20/30/31 probes, +/-12V DC, +/-2.5A
Order number 1410.4744.02
External attenuator
10:1, 2.0 GHz, 1.3 pF, 60 V DC, 42 V AC (peak) for R&S®RT-ZD20/30 probes. Included in R&S®RT-ZD10.
Order number 1800.0004.02
Power deskew fixture
Deskew fixture for voltage and current probes for power measurements; includes USB 2.0 cable for power supply
Order number 1326.3641.02
3D probe positioner
3D positionier with central tensioning knob for easy clamping and positioning of probes (span width: 200 mm, clamping range: 15 mm)
Order number 1335.7775.02
Application bundle (R&S®RTA-K1, -K2, -K3, -K5, -K6, -K7, -K31, -K36, -K37 and -B6)
Application bundle contains triggering and decoding I²C/SPI (R&S®RTA-K1), UART/RS-232/RS-422/RS-485 (R&S®RTA-K2) and CAN/LIN (R&S®RTA-K3), I²S (R&S®RTA-K5), MIL-1553 (R&S®RTA-K6), ARINC429 (R&S®RTA-K7), spectrum analysis and spectrogram (R&S®RTA-K37), power analysis (R&S®RTA-K31), frequency response analysis (R&S®RTA-K36), arbitrary generator (R&S®RTA-B6) for R&S®RTA4000 models
Order number 1335.7998.02
Application bundle (R&S®RTA-K1, -K2, -K3, -K5, -K6, -K7, -K31, -K36, -K37 and -B6)
Application bundle contains triggering and decoding I²C/SPI (R&S®RTA-K1), UART/RS-232/RS-422/RS-485 (R&S®RTA-K2) and CAN/LIN (R&S®RTA-K3), I²S (R&S®RTA-K5), MIL-1553 (R&S®RTA-K6), ARINC429 (R&S®RTA-K7), power analysis (R&S®RTA-K31), frequency response analysis (R&S®RTA-K36), spectrum analysis and spectrogram (R&S®RTA-K37), arbitrary generator (R&S®RTA-B6) for R&S®RTA4000 models * ONLY distributed in North America
Related products
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes
1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).
2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.
3. Participation is free of charge and not dependent on the purchase of goods or services.
4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.
5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:
Prize: 1x R&S®RTB2000 Digital Oscilloscope
6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.
7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.
8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.
9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.
10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.
11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.
12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.
13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.