For NB-IoT applications to function correctly, sufficient network coverage is required. Coverage must be measured to ensure a robust NB-IoT connection. Rohde & Schwarz mobile network testing provides a unique combined test solution that accurately measures the DL coverage using network scanners. It measures the device/network interaction, UL behavior, protocol, signaling load and energy efficiency during communications using NB-IoT devices connected to R&S®ROMES.
20-Feb-2018
Three hardware modifications of the option External Measurements ZVR-B25 enable the bidirectional network analyzers of the ZVR-family to carry out 4-port measurements. For the measurements, the four ports PORT 1, PORT 2, INPUT b1 and INPUT b2 at the front panel of the ZVR(E) are utilized. The fifth connector, ie OUTPUT a1, is not required for this purpose. As detailed below, the necessary modifications of the test set of the analyzer are described for the model ZVR. Of course, the modifications can be done in a similar way for the model ZVRE as well.
28-Jul-1998 | AN-No. 1EZ25
Using R&S®ELEKTRA Migration Tool
The R&S®ELEKTRA EMC test software is the successor of the R&S®EMC32 EMC measurement software. Like the R&S®EMC32 EMC measurement software, the R&S®ELEKTRA offers a solution that controls complete EMC systems and automates measurements on equipment under test (EUT) that is being tested for emissions (EMI) and immunity (EMS) compliance. It has more features and test types compared to R&S®EMC32.As both software platforms use different file formats, R&S®EMC32 users who upgrade their existing software to the R&S®ELEKTRA platform need to perform a file conversion before migrating their data to the R&S®ELEKTRA platform. This is done by using the R&S®ELEKTRA Migration Tool, which is installed automatically with each R&S®ELEKTRA installation.This Application Note describes how to use the R&S®ELEKTRA Migration Tool (version 4.4 onwards) for converting the backup data into the XML format that can be interpreted by the R&S®ELEKTRA software. It also provides recommended conversion steps (Chapter 5) and troubleshooting tips (Chapter 6). For instructions on migrating the data using R&S®ELEKTRA Migration Tool below version 4.4, refer to the R&S®ELEKTRA user manual. For better user experience, we recommend using the latest software version for migration.This Application Note does not describe the steps to backup data using the R&S®EMC32 or R&S®ES-SCAN software. For procedures on how to do so, refer to their respective manuals.
04-May-2023 | AN-No. 1SL396
In the satellite sector, components, subsystems and entire satellites must be qualified in a thermal vacuum chamber before they can be used in space. This qualification proves that equipment can not only survive but also function in the harsh conditions encountered during launch and in space.
05-Oct-2022
Calibration and Verification Solution
The UWB (Ultra-Wideband) technology is a short range wide-band radio technology specified for device to device communication operating in unlicensed spectrum. It is an RF positioning technology that enables accurate and secure peer-to-peer ranging between mobile devices with robust resistance to interference while consuming very low energy and coexisting well with other radio communication systems. UWB is used for a variety of different applications, such as asset tracking, secure payment, personal tracker, real time location services and keyless access and start of a vehicle etc. According to ABI Research forecasts, there will be well over 1 billion UWB annual device shipments by 2026. Almost every smart phone shipped in 2026 will support UWB services.Talking about testing aspect of a UWB device, in general two test methodologies can be adopted as other wireless products, either the traditional testing mode (so-called conducted test mode) with wired RF connection between the test measurement equipment and device under test (DUT) or over the air (OTA) test mode in an OTA anechoic chamber. Sometimes, it is not always possible or necessary to perform the tests under conducted mode due to the limiting factors, e.g. cost, space, complexity and direct access to the RF connectors of the product. In this case, OTA testing is then becoming a non-evitable approach. Moreover, OTA testing reflects the usage of DUT in a real condition.In this application note, R&S® OTA test solution covering transmitter (Tx), receiver (Rx) and Time of Flight (ToF) testing in Wireless Automated Testing (WMT) environment is described. The measurement results throughout the whole document are based on NXP Trimension™ NCJ29D5 UWB automotive IC.
12-Apr-2023 | AN-No. 1SL394
Performing essential RF tests gets your Sigfox device ready for certification and deployment
15-Nov-2018
Present-day sound studios are hardly conceivable without A/D converters. A/D converters are essential components when music is recorded and they directly influence the recording quality. The current Application Note describes a test program permitting automatic measurements of all parameters of sound studio equipment with the aid of Audio Analyzers UPD or UPL. Measuring converter chips with mostly serial interfaces that are not to standard are not the subject of this Application Note.
26-Jun-1998 | AN-No. 1GA30
TETRA, the TErrestrial Trunked RAdio, is the professional mobile radio standard (PMR) used world wide by governmental safety and security authorities and organizations, as well as by private utilities from energy suppliers through to transport. Rohde & Schwarz provide test instruments idealy suited for both the development and production of TETRA base stations and user equipment, as well as for network planning, network coverage and quality of service, network monitoring and optimization, maintenance, and service. This Application Note shows examples for measurements with R&S instruments covering the entire range of TETRA test requirements.
26-Apr-2013 | AN-No. 1MA189
Compliance testing is essential to ensuring that dynamic random access memory (DRAM) signals meet the JEDEC specifications for parameters such as timing, slew rates and voltage levels. For system verification and debugging, eye diagram measurements are the most important tools for efficiently analyzing the signal integrity in any digital design. The specific nature of DDR requires a dedicated solution with a powerful read/write separation to get meaningful eye diagrams on the DDR data bus.
19-Feb-2019
This application note highlights various aeronautical radio navigation signals such as VHF omnidirectional radio range (VOR), instrument landing system (ILS) for glide slope (GS) and localizer (LLZ), as well as marker beacon (MB). Rohde & Schwarz test and measurement solutions for avionics navigation equipment are introduced based on application scenarios, including calibration, research and development, field tests, and transceiver testing.
01-Feb-2012 | AN-No. 1MA193
Current Radar development is focusing the area of signal processing. This is taken into account by this educational note, where the R&S®SMW / SMBV instruments on the transmitter side and R&S®FSW / FSV instruments on the receiver side are combined to a closed loop Radar system, performing radar detection by means of pulse compression and digital signal processing. Appropriate Rohde & Schwarz sofware tools for such applications are described as well as the interface between the tools and the test instruments. Target reader group are engineering students who want to perform tests using pulsed or chirped signals.
20-Nov-2014 | AN-No. 1MA234
Using a Vector Network Analyzer from the ZVR family, not only magnitude and phase can be measured, but also group delay and even phase delay. Whereas phase delay measurements produce the highest accuracy for the electrical length of non-dispersive devices under test, such as coaxial cables, group delay measurements also give a detailed insight into the frequency dependent delay characteristics of dispersive devices, such as filters. In addition to the traditional step aperture technique, Vector Network Analyzers from the ZVR family offer a frequency aperture technique, which allows a well defined and constant aperture for group delay measurements also for a nonlinear frequency sweep.
28-Jul-1998 | AN-No. 1EZ35
The 3GPP TS 36.521-1 “Radio transmission and reception” LTE User Equipment (UE) conformance specification defines the measurement procedures for LTE terminals with regard to their transmitting characteristics, receiving characteristics and performance requirements as part of the 3G Long Term Evolution (3G LTE) standard. This application note describes how to use the LTE Frequency Division Duplex (FDD) and Time Division Duplex (TDD) measurement functionality provided by the R&S®CMW500 wideband radio communication tester to perform LTE transmitter and receiver measurements according to this test specification.
17-May-2013 | AN-No. 1CM94
An error in DVB-T2 signal feed to the transmitter can cause failure of the entire DVB-T2 network. For this reason, the established ETSI TR 101 290 DVB measurement guidelines have been expanded to include measurements for the new T2-MI interface. The instruments of the R&S®DVMS family monitor T2-MI signals by performing these newly defined measurements and even provide in-depth analysis of these signals.
01-Sep-2011
The converters offered for the R&S®ZVA family extend the network analyzers' frequency range up to 325 GHz. This Application Note describes typical measurements on millimeter-wave mixers and millimeter-wave frontends. It also discusses a signal identification method that enables spurious measurements to be performed in the millimeter-wave range using an R&S®ZVA network analyzer in conjunction with a converter.
17-Nov-2008 | AN-No. 1EZ57
All digital oscilloscopes are temporarily blind. During this blind time the user will miss critical signal events at his device under test. Thus, it is necessary to understand the impact of blind time to the measurement. This application note explains the background of blind time and points out why a high acquisition rate is important. It furthermore explains the R&S RTO oscilloscope capabilities and how they help for faster debugging, measurement and analysis.
17-May-2011 | AN-No. 1ER02
Analyzing high speed datacom interfaces is an important task and ensures signal integrity. One major challenge of this analysis is the connection between the physical interface and the oscilloscope, as most of the datacom interfaces do not provide test connections suitable for RF. A test fixture is required as a bridge between the high speed datacom IF and the RF connector of the oscilloscope, but this will affect the signal integrity measurement. The R&S®RTP and R&S®RTO2000 oscilloscopes with the advanced jitter option can analyze and separate jitter contributions. Additionally, the option can evaluate the impact of test fixtures and traces inherently and give the user a good understanding of the impact of their test setup.
31-Mar-2021
This Application Note provides an overview of the Bit Error Rate (BER) test capabilities of the Universal Radiocommunication Tester CMU300 on GSM / EDGE Base Stations. It includes information about measurement principles, the supported test environment and channels, CMU settings, operation, and ordering information.
15-Jan-2002 | AN-No. 1CM32
The R&S®FSW signal and spectrum analyzer with the R&S®FSW-K160R realtime option and the R&S®FSW-K6 pulse measurement option is ideal for testing modern radars.
04-Jul-2013
Vector Network Analyzers of t ZNA and ZNB family are able to measure magnitude and phase of complex S-parameters of a device under test (DUT) in the frequency domain. By means of the inverse Fourier transform the measurement results can be transformed to the time domain. Thus, the impulse or step response of the DUT is obtained, which gives an especially clear form of representation of its characteristics. For instance, faults in cables can thus be directly localized. Moreover, special time domain filters, so-called gates, are used to suppress unwanted signal components such as multireflections. The measured data "gated" in the time domain are then transformed back to the frequency domain and an Sparameter representation without the unwanted signal components is obtained as a function of frequency. As usual, other complex or scalar parameters such as impedance or attenuation can then be calculated and displayed.
30-Jul-2020 | AN-No. 1EP83
Simultaneous DL throughput verification and UL transmission testing with the R&S®CMW500
29-Jul-2009
During the design process of chipsets or modules, FPGA-based hardware emulators are utilized to perform early tests with real test and measurement instruments. These hardware emulators usually run at artificially reduced speed, but apart from that function like the finished design. In this application note we explain how to test FPGA-based hardware emulators using Rohde & Schwarz vector signal generators for creating suitable real-time test signals at reduced sample rates. We further explain how to correctly adapt AWGN signal generation and fading simulation for “slow I/Q”.
10-Dec-2012 | AN-No. 1GP95
The R&S®CMW wideband radio communication tester platform (R&S®CMW500, R&S®CMW270) uses high accuracy distance measurements (HADM) with phase based ranging (PBR) for a comprehensive and fully automated test solution to verify Bluetooth® Low Energy physical layer functionality
06-Sep-2023
Rohde & Schwarz offers a complete test solution for WiMAX applications by combining its Signal Generator R&S SMU200A and Signal Analyzer R&S FSQ plus the appropriate options. This application note provides an overview of the differences between OFDM and OFDMA and demonstrates, how convenient it is to generate and analyze WiMAX OFDMA signals according to standard IEEE 802.16e-2005.
23-May-2007 | AN-No. 1EF58
The R&S®ELEKTRA EMC test software is a solution that controls complete EMC systems and automates measurements on equipment under test that is being tested for emissions and immunity compliance. It can be used to remotely control R&S®AdVISE, which is a visual inspection software to monitor up to 32 different Regions of Interest in one video for visible and audible changeThis Application Note describes how to set up R&S®ELEKTRA and R&S®AdVISE for remote testing.
23-Jul-2020 | AN-No. 1S005
EMI Automotive Band Evaluation extension is an on-board EMI measurement sequence in broadband and communications frequency bands for automotive and aerospace applications. This application notes shows how to configure, run, and automatically document tests in a sequence coming with EMC32-K51.
17-Jul-2014 | AN-No. 1SP07
The new WiMAX radio technology - worldwide interoperability for microwave access - is based on wireless transmission methods defined by the IEEE 802.16 standard. WiMAX has been developed to replace broadband cable networks such as DSL and to enable mobile broadband wireless access. Rohde & Schwarz offers a complete test solution for WiMAX applications by combining its Signal Generator R&S SMU200A and Signal Analyzer R&S FSQ plus the appropriate options.RuS_WiMAX_OFDM is a 10 minutes video on WiMAX OFDM measurements.Please see also 1MA96 for General information about the WiMAX standard and 1MA97 for Generating and analyzing 802.16-2004 and 802.16e-2005 signals.
11-Jul-2006 | AN-No. 1EF57
This application note describes how Bluetooth devices are tested and measured using the R&S CMU200/CBT by means of the CMUgo/CBTgo remote control program or manual operation.
06-Oct-2006 | AN-No. 1CM50
In response to the growing number of WLAN modules that also support a cellular network (converged devices), CTIA published a plan with new tests in August 2006 that certifies Wi-Fi conformance. This Application Note first addresses the transmitter tests of the CTIA plan. For these tests Rohde&Schwarz offers preprogrammed instrument setups. They enable you to perform the measurements on the WLAN test set easily and quickly. Moreover, this Application Note shows how you can check the spectrum transmit mask defined for OFDM by means of only one keystroke on the Rohde&Schwarz spectrum analyzers.