This application note and associated application software may be used to conduct psychoacoustic speech quality evaluation for Voice over LTE (VoLTE) connections. The measurements are based on recommendations ITU-T P.862 and ITU-T P.863, respectively.
21-Feb-2014 | AN-No. 1MA204
This application note provides an application program for level alignment, test automation and reporting with PESQ, POLQA and delay measurements on the Audio Analyzer R&S®UPV or R&S®UPV66.
08-May-2013 | AN-No. 1GA62
Recent mobile test methods could not evaluate the quality of data reduced speech signals with different coded and decoded signals. The Perceptual Evaluation of Speech Quality (PESQ) provides the solution for this measuring problem. WCDMA PESQ is an add-on tool for CMUgo for automatic measurement of the PESQ for WCDMA mobile phones according to recommendation ITU-T P.862.1 featuring selectable fading profiles and variable Additional White Gaussian Noise (AWGN).
05-Jan-2012 | AN-No. 1MA137
This application note describes how measurement results can be logged over time in the audio analyzer R&S® UPV. A Visual Basic.NET application program is included which stores results to ASCII files.
29-Jun-2012 | AN-No. 1GA59
This application note provides a program which allows to record total harmonic distortion, single harmonic distortion factors and level with one generator sweep. The executable may be installed and used without caring about programming. The source code is provided as basis for custom modifications.
16-Jul-2011 | AN-No. 1GA56
This application note provides a tool for printing a report about measurement results on the audio analyzer R&S® UPV. The executable can be freely configured to include any result graphs and figures into the report. In addition it is an application example for a class library which can be included into custom application programs to add a printing function.
18-Jul-2011 | AN-No. 1GA57
This application note gives background information about the psychoacoustic measurements PESQ® (Perceptual Evaluation of Speech Quality) and PEAQ® (Perceptual Evaluation of Audio Quality). It also describes how to perform these measurements using the Rohde & Schwarz Audio Analyzer.
03-Apr-2009 | AN-No. 1GA49
This Application Note describes how the R&S® UPV and R&S® UPP200 audio analyzers can be used to replace the obsolete Agilent model 8903B audio analyzer in remote control applications.
24-Nov-2010 | AN-No. 1GA54
This application note explains how to use the Audio Analyzer R&S UPV for measurements of maximum sound pressure level of headphones according to EN50332. It is possible to measure a combination of music player / FM receiver and headphones, the maximum output voltage of a player / FM receiver alone or the wideband characteristic voltage of headphones alone. An application program is available for download as installer file and as VB.NET project.
17-Jun-2009 | AN-No. 1GA48
Most application notes for audio analyzer R&S® UPV include an application program which runs locally using the universal sequence controller option UPV-K1. This application note explains how sequence control programs can be modified to run on a remote PC using remote control option UPV-K4.
30-Jun-2012 | AN-No. 1GA60
This application note investigates and discusses the influence of wideband noise on harmonic distortion measurements.
06-Jul-2011 | AN-No. 1GA55
PESQ measurements employ a level adaptation algorithm and are hence widely insensitive to absolute level. However, if the tests are performed via a speech codec, the driving level of the codec has an influence on the MOS result. Therefore careful alignment of the level is required. This application note provides an application program which runs on the Audio Analyzer R&S UPV or R&S UPV66 and can be used to calibrate signal levels for the PESQ measurement.
30-Jun-2011 | AN-No. 1GA50
This application note provides an application program for the audio analyzer R&S®UPV which calculates and displays the loudness of non-stationary sounds according to ISO 532-1 (Zwicker method). The theoretic background of the evaluation method is briefly explained.
14-Dec-2017 | AN-No. 1GA67
This application note provides software and instructions for a simple check of the acoustic performance of mobile phones. It targets mainly service centers and repair workshops which have to perform incoming tests of defective mobile phones and final tests of repaired mobiles. A focus is set on short test times and ease of use, without compromising accuracy and repeatability of results.
14-Dec-2017 | AN-No. 1GA69
A large variety of measurements is performed in audio engineering in order to ensure transmission quality of analog and digital devices. An audio analyzer suitable for all these tasks will, therefore, incorporate a multitude of functions, resulting in a correspondingly large number of settings.This application note is to help test engineers using the R&S®UPP and R&S®UPV audio analyzers. It presents setting examples for all basic audio measurements to be performed immediately. For each setup, information is given on the type of measurement, the underlying standards, and on how to modify the graphic display results.
07-Jul-2014 | AN-No. 1GA64
This application note provides an application program and instructions for performing speech quality tests and delay measurements in a live network, using the R&S®UPV audio analyzer.
14-Dec-2017 | AN-No. 1GA68
Acoustic properties like reverberation time and early reflections are important for test rooms as well as for speech intelligibility and music performance in assembly rooms and concert halls. This application note explains the basics behind these properties and offers an application program for their measurement.