Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
735 Results
R&S IMS Hardware Setup according IEC / EN 61000-4-3 (radiated immunity)
29-Mar-2007 | AN-No. 1SP32
RF Level Measurement Accuracy of DTV Test Receivers
20-Jul-2001 | AN-No. 7BM12
Measurements on S-VHS and RGB Signals with Video Measurement System R&S VSA and Video Analyzer R&S UAF
21-Feb-2003 | AN-No. 7BM29E
Testing Power Amplifiers for 3G Base Stations
04-Sep-2002 | AN-No. 1MA40
Lip-Sync Measurement (AV Delay) for TV Displays
21-Apr-2010 | AN-No. 7BM77
The analog demodulation measurement application R&S®FSxx-K7 performs frequency and phase settling time measurements using a modern wideband concept..
18-Jun-2022 | AN-No. 1EF112
Power Measurement on Pulsed Signals with Spectrum Analyzers
16-Jan-2003 | AN-No. 1EF48
From designing a test setup to performing accurate measurements
This application note discusses important aspects of double-pulse test setups as well as how to perform accurate measurements. Double-Pulse testing is a standard test-method.
22-Mar-2021 | AN-No. GFM347
For system verification and debugging, eye diagram measurements are the most important tools for efficiently analyzing the signal integrity in any digital design
19-Feb-2019
This application note briefly summarizes the history of SCPI and outlines in which fields of application a SCPI based test system software has still advantages over a driver (e.g. IVI) based approach.
18-Oct-2017 | AN-No. 1GP98
This document answers frequently asked questions regarding Rohde & Schwarz Broadband Amplifiers. It describes remote operation and monitoring of the R&S® Broadband Amplifier series through a standard web browser.
04-Nov-2016 | AN-No. 7TA1
Remote Emulation with the R&S<sup>®</sup>SMC100A Signal Generator
28-Feb-2012 | AN-No. 1GP90
MIPI D-PHY is a low-power, cost-effective physical layer interface, essential in mobile devices and advanced technology systems. It's a high-speed, source-synchronous interface used in smartphone cameras, smartwatch displays, drones, in-car entertainment, automobile cameras, and radar sensors. This application note explores MIPI D-PHY's features, functionality, and testing practices for device compliance, addressing common issues. It highlights Rohde & Schwarz's equipment for ensuring compatibility and solving issues with MIPI D-PHY, aligned with MIPI D-PHY specification version 2.5.Developed by the MIPI Alliance, D-PHY connects cameras and displays to a host processor via CSI-2 or DSI protocols. It features a master-slave, asymmetrical design for reduced link complexity. Key aspects include a unidirectional clock, optional data signal directions, different data rates for half-duplex operation, point-to-point communication, and high-speed (HS) and low-power (LP) modes for data transfer and battery preservation. In HS mode, D-PHY uses differential signaling with specific impedance, while in LP mode, it operates in a single-ended manner with high impedance termination.The application note from Rohde & Schwarz provides insights into characterizing and debugging MIPI D-PHY, offering conformance verification with MIPI Alliance standards and protocol decoding options.
31-Jan-2024 | AN-No. 1SL410
The R&S®SMA100B offers outputs for the analog input signal of the ADC as well as the clock input signal in one single instrument - both with outstanding signal purity.
11-Jan-2021 | AN-No. 1GP66
DOCSIS has become the established standard for return channels when it comes to implementing interactive services in broadband cable networks. The quality of these signals is essential to network efficiency. The analysis can be done using the highprecision R&S®ETL, R&S®EFA and R&S®FSH3-TV TV test receivers that have proven themselves in the downstream. These T & M instruments can be quickly and easily configured for measuring the upstream.
13-Jul-2012
Time Domain Measurements using Vector Network Analyzer ZVR
04-Aug-1998 | AN-No. 1EZ44
Using R&S®CMU200 Drivers in Microsoft Visual Studio 2008 with Visual Basic .NET and C#
30-Jun-2009 | AN-No. 1MA157
Remote Emulation with the R&S<sup>®</sup>SMB100A RF and Microwave Signal Generator
20-Mar-2012 | AN-No. 1GP89
Virtual Embedding Networks for ZVR and ZVC Network Analyzers
25-Sep-1998 | AN-No. 1EZ45
Simple Network Management Protocol - Remote Controlling for Monitoring Devices
16-Mar-2007 | AN-No. 7BM65
CDMA2000® 1xRTT / 1xEV-DO Measurement of time relationship between CDMA RF signal and PP2S clock
09-Nov-2007 | AN-No. 1CM33
This application note introduces the IVI High Speed LAN Instrument Protocol (HiSLIP) and outlines its features. HiSLIP is the successor to the VXI-11 LAN remote control protocol. This document also describes guidelines for using this protocol.
12-Nov-2014 | AN-No. 1MA208
The demand having a snubber circuit in the power supply topology leads to specific verification methods during the design which are the main focus within this document.
23-Jun-2021 | AN-No. 1SL363
Doc.A/74 ATSC Receiver Performance Tests Made Easy with the R&S<sup>®</sup> SFU Broadcast Test System and the R&S<sup>®</sup> SFE Broadcast Tester
27-Sep-2012 | AN-No. 7BM71
R&S<sup>®</sup>NRP-Z Power Sensor Programming Guide
06-Mar-2012 | AN-No. 1GP69
The R&S®ZNA vector network analyzer with integrated LO output and direct IF input options is a simple, cost-effective solution for 2-port and 4-port measurements using Rohde & Schwarz mmWave converters.
19-Jul-2021
This application note introduces the R&S®Pulse Sequencer software and outlines necessary steps to generate a real life RF signal environment.
17-Jan-2017 | AN-No. 1MA288
This application note describes topics such as: characteristics and implementation of RF signal paths, image responses etc. for the R&S®ESW EMI test receiver.
19-Nov-2020 | AN-No. 1EE26