R&S®NGU source measure units, front view R&S®NGU source measure units, front view R&S®NGU source measure units, front low R&S®NGU source measure units, side view R&S®NGU source measure units, side view R&S®NGU source measure units, side view R&S®NGU source measure units, back view R&S®NGU source measure units, hero view

Key facts

  • Two/four quadrants: operates as source and sink
  • High speed data acquisition (FastLog function)
  • Voltage priority and current priority mode
  • High-capacitance mode
  • Intuitive, price-transparent online product configurator

Starting at CAD 11,900

The top-class in supplying power

The extremely high accuracy and fast load recovery times make R&S®NGU source measure units (SMU) perfect for challenging applications, such as:
- battery and power consumption tests
- supplying wireless devices with power
- simulation of voltage drops
A special ammeter design is used to precisely measure current drains from nA to A in one pass – no need to make multiple measurement sweeps. The short recovery times enable the instruments to handle fast load changes when mobile communications devices switch from sleep to transmit mode. Every detail is detected down to 2 μs resolution with high speed data acquisition. R&S®NGU source measure units have two or four quadrant architecture to function both as a source and a sink.
Configure your own R&S®NGU SMU with our online configurator tool and benefit from full price transparency, ease of configuration along with fast processing and shipment through an authorized distribution partner of your choice
Click "Configure and quote" and start configuration now.

Features & benefits

Two/four quadrants: operates as source and sink

Simulates batteries or loads

The two/four-quadrant architecture of these source measure units can function as a source and a sink to simulate batteries or loads. The SMU automatically switches from source mode to sink mode as soon as the externally applied voltage exceeds the set nominal voltage. With its four-quadrant architecture, the R&S®NGU401 can supply positive or negative voltages or currents and can act as a source or sink in both polarities.

Four-quadrant architecture of the R&S®NGU401
Open Lightbox

Four-quadrant architecture of the R&S®NGU401

R&S®NGU supplies positive or negative voltage in source or sink mode.

High speed data acquisition

FastLog function

The R&S®NGU source measure units offer the FastLog function to capture voltage and current measurement results. This data can be stored on an external USB storage device or transferred to an external PC via USB or LAN. With an acquisition rate of up to 500 ksample/s, voltage and current results are available every 2 μs.

FastLog high speed data acquisition
Open Lightbox

FastLog high speed data acquisition

The FastLog function follows voltage/current variations with a resolution of up to 2 μs.

Voltage priority and current priority mode

Optimized for voltage/current regulation

In voltage priority mode, fast voltage regulation provides short recovery times of less than 30 μs. Current regulation is designed to be somewhat slower to avoid oscillation. When precise and quick current regulation is desired, the R&S®NGU source measure units can be operated in current priority mode. Optimized for fast current regulation (load recovery time < 50 μs), this mode allows tasks such as LED testing, which are sensitive to even short current spikes.

Voltage/current priority mode
Open Lightbox

Voltage/current priority mode

The standard mode provides fast voltage regulation when there is risk of current overshoot. The special mode has fast and risk-free current regulation.

High-capacitance mode

Compensate capacitors

Typical measurement configurations often have capacitance at the DUT input. Connecting the power supply with leads causes low pass behavior from the leads and capacitance. In high-capacitance mode, R&S®NGU source measure units compensate for the capacitance and display the current directly at the DUT.

Fast load regulation

Handles fast load changes

Consumer electronics such as mobile phones and IoT devices require very little power in sleep mode. However, the current increases abruptly as soon as the device switches to transmit mode. A power supply for these DUTs must handle load changes from a few nA to the ampere range without creating voltage drops or overshoots.

Optimized load recovery time
Open Lightbox

Optimized load recovery time

Power supplies often respond to load changes with overshoot and slow recovery times. The R&S®NGU source measure units have recovery times of < 30 μs.

Easy to use, price transparent configurator

We help customers choose the right T&M instrument quickly, easily and with full price transparency. The R&S®NGU and other instruments from the R&S®Essentials portfolio can now be configured online, providing the following benefits:
- user-friendly and easy to navigate configurator
- full cost transparency at every configuration step
- fast order processing through authorized distribution partners 
- next-day delivery from selected partners

Available models

Available models
Models
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Starting at

R&S®NGU201

Order number 3639.3763.02

Number of output channels
1
Max. output power
60 W
Output voltage per channel
0 V to 20 V
Output current per channel
≤ 6 V: 8 A
> 6 V: 3 A
Starting at
CAD 12,900

R&S®NGU401

Order number 3639.3763.03

Number of output channels
1
Max. output power
60 W
Output voltage per channel
-20 V to +20 V
Output current per channel
≤ 6 V: ±8 A
> 6 V: ±3 A
Starting at
CAD 11,900

R&S®NGU411

Order number 3639.3763.04

Number of output channels
1
Max. output power
20 W
Output voltage per channel
-20 V to +20 V
Output current per channel
≤ 10 V: ±2 A
> 10 V: ±1 A
Starting at
CAD 7,700

Available options

Hardware options
Product
Description
R&S®NGU-B105

Order number 3661.0763.02

Description

IEEE-488 (GPIB) interface

Software options
Product
Description
R&S®NGU-K103

Order number 3662.9335.02

Description

Digital trigger I/O

R&S®NGU-K104

Order number 3663.0390.02

Description

Digital voltmeter function (R&S®NGU201 only)

R&S®NGU-K106

Order number 3663.0625.02

Description

Battery simulation (R&S®NGU201 only)

General accessories
Product
Description
R&S®HZN96

Order number 3638.7813.02

Description

19'' rack adapter, 2HU

Related video

Webpage, VNC & FTP on R&S®DC Power Supplies

Learn how easy it is to control and operate our instrument from any location via ethernet-based remote services

High Precision Power Supplies

The R&S®NGM/L/U come with a linear design, 2 or 4-quadrant operation, high readback resolution, and advanced functionalities.

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.