Key facts
- Max. output power: 800 W
- Max. voltage per channel: 32 V or 64 V
- Max. current per channel: 10 A or 20 A
- Up to 250 V or 80 A in series or parallel operation
- Intuitive, price-transparent online product configurator
Key facts
The R&S®NGP800 DC power supply series, comprising of five models with 400 W or 800 W, provides maximum power at a variety of operating points. The two or four 200 W outputs can each supply up to 64 V or up to 20 A. Electrically equivalent and galvanically isolated outputs can be wired in series or parallel for up to 250 V or 80 A.
The R&S®NGP800 DC power supply series is ideal for a variety of T&M scenarios: automotive, R&D, manufacturing and general purpose use.
Configure your R&S®NGP800 with our online configurator tool for:
- full price transparency
- ease of configuration
- fast processing of your request and purchase from authorized distributor of your choice
Click "configure and quote" and start your configuration now.
High-resolution touch display for easy operation
The large high-resolution touch display makes operation easy. Quickly navigate through the menus to access all functions and settings. Enter values much faster with the virtual keyboard instead of a knob. The home screen gives you a clear overview of all your channels. Each channel can be selected for a more detailed view with a wide variety of additional information, such as statistics and icons indicating the status of set protection or special functions.
The home screen gives a clear overview of all channels
Get the maximum power at various operating points
Unlike with single range power supplies, you can generate variable voltage and current combinations within the overall power limit of 200 W per channel. This technology makes your power supply a lot more versatile, covering a wider range of applications.
V/I-curves for 32 V output and 64 V output
Up to 250 V or 80 A
If your application requires more voltage or current, connect the outputs in series or parallel and get up to 250 V (R&S®NGP824) or 80 A ( R&S®NGP804) - for the flexibility you always wanted. Using the tracking function, voltage and current are adjusted on all selected channels simultaneously.
Parallel & serial operation
Integrated statistics
The built-in measurements reduce the need for an external multimeter and simplify the setup. The separate voltage and current meters on each output have a resolution of 1 mV and 0.5 mA over the full output range of 64 V and 20 A. Integrated statistics show the min, avg and max values for power, voltage and current as well as the energy count.
One-channel-view with details and integrated statistics
Key to long-term monitoring
Logging data is key to long-term monitoring, reviewing test setups and repeating test conditions when analyzing power behavior or optimizing power consumption. The R&S®NGP800 power supplies simultaneously log voltage and current measurements over time on all outputs. You can easily export the timestamped data as a .CSV file for reports and documentation.
Logging setup dialog
QuickArb
Emulate the normal behavior of your power subsystem early in the design process and simulate power problems for DUT design verification. The QuickArb function lets you generate voltages that vary over time and current sequences of output changes with dwell times down to 1 ms. Load up to eight subgroup files into one sequence to create complex patterns.
Fast programming of sequences with the Arb Editor
Display of measured data
The Graphical View function allows fast and convenient analysis, especially of changing processes, such as charging and discharging or switching between different operating states of a DUT. Integrating all measurements in one box not only reduces the complexity of the test setup, but also ensures the integrity and correlation of all measurements by design.
The Graphical View function interface on an R&S®NGP800 power supply
Control your instrument from anywhere
Via VNC connection the R&S®NGP800 power supplies can be controlled and operated from any location. All functions that can be reached by manual operation can also be accessed via remote control by VNC. The connection between power supply and PC can be established via LAN in the same network.
Remote control of R&S®NGP800 power supply via VNC
We strive to give customers the right T&M instrument quickly, easily, and with full price transparency. The R&S®NGP800 and other instruments from the R&S Essentials portfolio can now be configured online, providing you with the following benefits:
- User-friendly and easy to navigate configurator
- Full cost transparency at every step of configuration
- Fast order processing through authorized distribution partners
- Next-day delivery from selected partners
Electrical specifications | |
Number of output channels | 2 or 4 |
Total output power | max. 400 W/800 W |
Maximum output power per channel | 200 W |
Output voltage per channel | 0 V to 32 V (32 V channels) 0 V to 64 V (64 V channels) |
Maximum output current per channel | 20 A (32 V channels) 10 A (64 V channels) |
Voltage ripple and noise (20 Hz to 20 MHz) | < 3 mV (RMS) < 30 mV (Vpp) (meas.) |
Current ripple and noise (20 Hz to 20 MHz) | < 3.5 mA (RMS) (meas.) |
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) | < 400 μs (meas.) |
Programming resolution voltage | 1 mV |
Programming resolution current | 0.5 mA |
Output measurements | |
Readback resolution voltage | 1 mV |
Readback resolution current | 0.5 mA |
Readback accuracy voltage ±(% of output + offset) | < 0.05 % + 5 mV (32 V channels) < 0.05 % + 10 mV (64 V channels) |
Readback accuracy current ±(% of output + offset) | < 0.1 % + 20 mA (32 V channels) < 0.1 % + 10 mA (64 V channels) |
Special functions | |
Measurement functions | voltage, current, power, energy |
Protection functions | OVP, OCP, OPP, OTP |
FuseLink function | ● |
Fuse delay at output-on | ● |
Sense function | ● |
Sink mode | – |
Output sequencing | ● |
Trigger input/output | ○ |
Arbitrary function | ● (QuickArb) |
Analog/modulation interface | – |
Data logging | ● (standard mode) |
Display and interfaces | |
Display | TFT 5" 800 pixel × 480 pixel WVGA touch |
Rear panel connections | 8-pin connector block per 2 channels |
Remote control interfaces: standard | USB, LAN |
Remote control interfaces: optional | IEEE-488 (GPIB) |
General data | |
Dimensions (W × H × D) | 362 mm × 100 mm × 451 mm |
Weight | 7.5 kg/8.0 kg |
Rack installation | R&S®ZZA-GE23 option |
Order number 5601.6000.02
IEEE-488 (GPIB) interface
Order number 5601.6300.03
Digital trigger I/O
Order number 5601.6200.03
Analog input
Order number 5601.4059.02
19" rack adapter, 2 HU
Maximize your bench performance and benefit from more than 19% of of fully equipped DC power supplies.