Key facts
- Bandwidth: 70 MHz to 300 MHz
- Sample rate: up to 2.5 Gsample/s
- Memory depth: up to 20 Msample
- ADC resolution: 10 bit
- Display: 10.1" capacitive touchscreen
Starting at 1 690 €
Key facts
Starting at 1 690 €
The R&S®RTB 2 series oscilloscopes combine the power of ten with smart operating concepts, making them the ideal all-purpose tool for students, hobbyists, technicians and engineers. As a successor to the highly capable R&S®RTB2000, the R&S®RTB 2 series features a 10-bit ADC, 10 Msample memory, and a 10.1-inch touchscreen.
Additionally, the R&S®RTB 2 series includes an integrated arbitrary waveform generator history and segmented memory capabilities. Furthermore, all RTB 2 models are MSO-ready, allowing the use of up to 16 digital channels with the appropriate probes.
These oscilloscopes offer four times the vertical resolution of standard 8-bit ADCs while maintaining fast sampling rates at all times. With the largest display and highest resolution in their class, they provide extensive capabilities for university laboratories, troubleshooting embedded designs during development, and for production and service departments.
The R&S®RTB 2 series is the perfect solution for anyone needing precise and reliable measurements.
Quick links
See small signal details in the presence of large signals
The R&S®RTB 2 features a customized Rohde & Schwarz engineered 10-bit A/D converter that delivers a fourfold improvement compared to conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltage across the switching device must be determined during the on/off times within the same acquisition.
10 Msample standard and 20 Msample interleaved
The R&S®RTB 2 offers a class-leading memory depth: 10 Msample per channel are available, even 20 Msample in interleaved mode. This is 10 times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates, e.g. when analyzing transients of switched-mode power supplies, and thus benefits from more detailed analysis results.
160 Msample with history function
Every R&S®RTB 2 is equipped with a standard segmented memory functionality. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. The variable segment size optimally utilizes the 160 Msample memory. In history mode, previous acquisitions in the maximum segmented memory depth of 160 Msample are available for further analysis.
16 additional digital channels
Every R&S®RTB 2 is MSO ready, which allows the R&S®RTB2-B1 option to enable up to 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and time-correlated to each other. For example, the delay between A/D converter input and output can conveniently be determined with the cursor measurements.
Generate analog and digital stimuli
The R&S®RTB-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns including. I2C, SPI, UART and CAN/LIN can be used.
Measure and display electrical potential
The R&S®RTB 2 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Standard measurement functions include DC, AC+DC (RMS) and AC (RMS).
Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTB 2 is activated at the push of a button and by simply entering the center frequency and span. Thanks to the R&S®RTB 2 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128 kpoints. Other practical tools include cursor measurements and autoset in frequency domain.
Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. By using statistical pass/fail evaluation, they assess quality and stability of a DUT. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S®RTB 2. This pulse output can be used to trigger actions in the measurement setup.
In the teaching lab, the R&S®RTB 2 oscilloscope is the perfect choice to teach students how to measure with an oscilloscope. It has an easy-to-use concept combined with state-of-the-art technology at an affordable price. The large 10.1" high-resolution screen shows every signal detail, and one instrument can be shared among several students. Reports can be efficiently created with the handy, flexible screen annotation tool.
Order number 1333.1005.02
Order number 1333.1005.04
Order number 1333.1005P40
Order number 1333.1005P41
Order number 1333.1005P42
Order number 1333.1005P43
Order number 1333.1005P50
Order number 1333.1005P51
Order number 1333.1005P52
Order number 1333.1005P53
Vertical system | ||
Analog channels | R&S®RTB 22; R&S®RTB 24 | 2; 4 |
Digital channels (opt.) | 16 | |
Bandwidth (-3 dB) | R&S®RTB 22/24 (with R&S®RTB-B2x1, R&S®RTB-B2x2 and R&S®RTB-B2x3 options) | 70 MHz, 100 MHz, 200 MHz, 300 MHz |
Rise time | R&S®RTB 22/24 (with R&S®RTB-B2x1, R&S®RTB-B2x2 and R&S®RTB-B2x3 options) | 5 ns, 3.5 ns, 1.75 ns, 1.15 ns |
Input impedance | 1 MΩ ± 2% with 9 pF ± 2 pF (meas.) | |
Input sensitivity | Max. bandwidth in all ranges | 1 mV/div to 5 V/div |
ADC resolution | 10 bit, up to 16 bit with high resolution decimation | |
DC gain accuracy | offset and position = 0, maximum operating temperature change of ±5°C after self-alignment | input sensitivity > 5 mV/div: ± 1.5% of full scale input sensitivity ≤ 5 mV/div: ± 2% of full scale |
Acquisition system | ||
Real-time sampling rate | 1.25 Gsample/s; 2.5 Gsample/s, interleaved | |
Acquisition memory | standard | 10 Msample; 20 Msample, interleaved; 160 Msample segmented memory |
Max. acquisition rate | 50 000 waveforms/s (300 000 in fast segmented memory mode) |
|
Horizontal system | ||
Timebase range | selectable between 1 ns/div and 500 s/div | |
Accuracy (after delivery/calibration) | ±2.5 ppm | |
Channel-to-channel skew | max. 800 ps (meas.) | |
Channel deskew | ±500 ns | |
Trigger system | ||
Standard trigger types | edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus | |
Optional trigger types | I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN | |
Trigger sensitivity | with DC, AC, LF reject | input sensitivity > 5 mV/div: < 0.8 div (meas.); 2 mV/div ≤ input sensitivity < 5 mV/div: < 1.5 div (meas.); input sensitivity < 2 mV/div: < 2 div (meas.) |
with HF reject all input sensitivities | < 1 div (meas.) | |
Analysis and measurement functions | ||
Automatic measurements | 32 | |
Cursor measurements | 4 | |
Waveform mathematics | 5 equations math on math (addition, subtraction, multiplication, division, square, square root, abs. value, reciprocal, inverse, common log., natural log., derivative, integral, low pass, track unipolar + bipolar on period, frequency, pulse width, duty cycle) | |
Mask testing | ||
Mask definition | elementary (tolerance mask around the signal) | |
History and segmented memory | ||
Number of segments | up to 13 107 | |
Protocol trigger and decode | ||
Supported protocols | I2C, SPI, UART/RS-232/ RS-422/RS-485, CAN, LIN | |
Waveform generator | ||
Resolution | 14-bit | |
Sample rate | 250 Mpoint/s | |
Amplitude | high-Z; 50 Ω | 20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp) |
DC offset | high-Z; 50 Ω | ±2.5 V; ±1.25 V |
Arbitrary | sampling rate; memory depth | max. 10 Msample/s; 16k point |
Logic analyzer (MSO) functionality | ||
Digital input channels | 16 | |
MSO memory depth | 10 Msample for every channel | |
MSO Bandwidth | 300 MHz (meas.) | |
MSO sampling rate | 1.25 Gsample/s | |
MSO input impedance | 100 kΩ ± 2 % || ~4 pF (meas.) at probe tips | |
Parallel buses | up to 2 | |
General data | ||
Dimensions | W × H × D | 390 mm × 220 mm × 152 mm (15.4 in × 8.66 in × 5.98 in) |
Weight | 2.5 kg (5.5 lb) | |
Display | 10.1" WXGA TFT color display (1280 × 800 pixel) | |
Interfaces | USB host with MTP, USB device, LAN, powerful web server for remote display and operation | |
Operating system | Embedded |
Order number 1801.8421.02
Mixed signal option for R&S®RTB 2 oscilloscope, 300 MHz
Enables up to 16 digital channels.
Order number 1803.1001.02
Passive probe, 300 MHz, 10:1
Order number 1333.2401.02
Passive probe, 500 MHz, 10:1
Order number 1409.7550.00
Passive probe, 500 MHz, 10:1
Order number 1333.1370.02
Passive probe, 38 MHz, 1:1
Order number 1333.0873.02
250 MHz passive high voltage probe
Order number 1409.7720.02
400 MHz passive high voltage probe
Order number 1409.7737.02
400 MHz passive high voltage probe
Order number 1333.0715.02
300 MHz logic probe, 8 channels
Order number 1333.0850.02
AC/DC 20 kHz current probe
Order number 1333.0844.02
100 kHz current probe
Order number 1409.7750K02
10 MHZ current probe
Order number 1409.7766K02
100 MHZ current probe
Order number 1409.7772K02
120 MHz current probe
Order number 1801.4932.02
120 MHz current probe
Order number 1409.7789.02
Power supply for probes
Power supply for R&S®RT-ZC10/20/30/31 probes, +/-12V DC, +/-2.5A
Order number 1801.8438.02
Application bundle (R&S®RTB-K1, -K2, -K3 and -K36)
Application bundle contains triggering and decoding I²C/SPI (R&S®RTB-K1), UART/RS-232/RS-422/RS-485 (R&S®RTB-K2), CAN/LIN (R&S®RTB-K3) and frequency response analysis (R&S®RTB-K36)
Order number 1333.1728.02
Front cover
Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000
Order number 1335.9290.02
Transit case with wheels for R&S®RTB
Order number 1333.1734.02
Soft bag
Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories
Order number 1333.1711.02
19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU
Order number 1335.7875.02
Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes
1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).
2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.
3. Participation is free of charge and not dependent on the purchase of goods or services.
4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.
5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:
Prize: 1x R&S®RTB2000 Digital Oscilloscope
6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.
7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.
8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.
9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.
10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.
11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.
12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.
13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.