R&S®RTB2000 oscilloscope

R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 Oscilloscope, Front view R&S®RTB2000 Oscilloscope, Side view R&S®RTB2000 Oscilloscope, Hero view R&S®RTB2000 Oscilloscope, Back view R&S®RTB2000 Oscilloscope, Front view R&S®RTB2000 Oscilloscope, Side view R&S®RTB2000 Oscilloscope, Application Image

Key facts

  • Bandwidth: 70 MHz to 300 MHz
  • Sample rate: up to 2.5 Gsample/s
  • Memory depth: up to 20 Msample
  • ADC resolution: 10 bit
  • Display: 10.1" capacitive touchscreen

More signal details with the power of 10

Power of ten (10-bit ADC, 10 Msample memory and 10.1" touchscreen) combined with smart operating concepts make the R&S®RTB2000 oscilloscopes the perfect tool for university laboratories, for troubleshooting embedded designs during development and for production and service departments.

  • Four times more vertical resolution than standard 8-bit ADCs.
  • Maintains fast sampling rates at all times
  • Largest display with highest resolution in its class

Features & benefits

Signal analysis: quick results

See small signal details in the presence of large signals

The R&S®RTB2000 features a customized Rohde & Schwarz engineered 10-bit A/D converter that delivers a fourfold improvement compared to conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltages across the switching device must be determined during the on/off times within the same acquisition.

10-bit A/D converter
Open Lightbox

10-bit A/D converter

The Rohde & Schwarz designed 10-bit A/D converter ensures highest signal fidelity at highest resolution.

Capture more time at full bandwidth

10 Msample standard and 20 Msample interleaved

The R&S®RTB2000 offers a class-leading memory depth: 10 Msample per channel are available, even 20 Msample in interleaved mode. This is 10 times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates, e.g. when analyzing transients of switched-mode power supplies, and thus benefits from more detailed analysis results.

10 Msample standard memory
Open Lightbox

10 Msample standard memory

Capture and analyze pulsed and burst signals over a long period with up to 20 Msample standard acquisition memory.

Segmented memory

160 Msample with history function

The R&S®RTB-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. Thanks to the variable segment size, the 160 Msample memory is optimally utilized. In history mode, previous acquisitions to the maximum segmented memory depth of 160 Msample are available for further analysis.

160 Msample segmented memory
Open Lightbox

160 Msample segmented memory

Capture the longest time periods with class-leading 160 Msample memory.

Logic analysis with the MSO option

16 additional digital channels

The R&S®RTB-B1 option turns every R&S®RTB2000 into an intuitive-to-use MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and time-correlated to each other. For example, the delay between input and output of an A/D converter can conveniently be determined using the cursor measurements.

Four-bit DAC signal change.
Open Lightbox

Four-bit DAC signal change.

The R&S®RTB2000 captures and analyzes analog and digital signals synchronously and in time-correlated to each other.

Waveform and pattern generator

Generate analog and digital stimuli

The R&S®RTB-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns for e.g. I2C, SPI, UART and CAN/LIN can be used.

Waveform and pattern generator
Open Lightbox

Waveform and pattern generator

In addition to common sine, square/pulse, ramp and noise waveforms, it outputs user-defined waveforms and 4-bit signal patterns.

Digital voltmeter

Measure and display electrical potential

The R&S®RTB2000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Measurement functions include DC, AC+DC (RMS) and AC (RMS) – included as standard.

Digital voltmeter
Open Lightbox

Digital voltmeter

The 3-digit voltmeter measures and displays the electrical potential difference between two points in an electric circuit.

Frequency analysis mode

Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTB2000 is activated at the push of a button and by simpling entering the center frequency and span. Thanks to the R&S®RTB2000 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128 kpoints. Other practical tools include cursor measurements and autoset in frequency domain.

Frequency analysis mode
Open Lightbox

Frequency analysis mode

The high-performance FFT functionality analyzes signals up to 128 kpoints.

Mask test mode

Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. By using statistical pass/fail evaluation, they assess quality and stability of a DUT. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S®RTB2000. This pulse output can be used to trigger actions in the measurement setup.

Mask test with result statistics
Open Lightbox

Mask test with result statistics

The pass/fail evaluation assesses the quality and stability of the DUT.

Ready for the teaching lab

In the teaching lab, the R&S®RTB2000 oscilloscope is the perfect choice to teach students how to measure with an oscilloscope. It has an easy-to-use concept combined with state-of-the-art technology – at an affordable price. The large 10.1" high-resolution screen shows every signal detail, and one instrument can be shared among several students. Reports can be efficiently created with the handy and flexible screen annotation tool.

Ready for the teaching lab
Open Lightbox

Ready for the teaching lab

Perfect instruments for everyday use at universities and colleges thanks to diverse functionality, rugged design and small footprint.

Available models

Available models
Models
Bandwidth
Sample rate
Max. memory depth
Optional MSO
Starting at

R&S®RTB-BNDL

Order number 1333.1005P98

Bandwidth
300 MHz
Sample rate
2,5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Starting at
Price On Request
Specifications
Vertical system
Analog channels R&S®RTB2002; R&S®RTB2004 2; 4
Digital channels (opt.) 16
Bandwidth (-3 dB) R&S®RTB2002/2004 (with R&S®RTB-B2x1, R&S®RTB-B2x2 and R&S®RTB-B2x3 options) 70 MHz, 100 MHz, 200 MHz, 300 MHz
Rise time R&S®RTB2002/2004 (with R&S®RTB-B2x1, R&S®RTB-B2x2 and R&S®RTB-B2x3 options) 5 ns, 3.5 ns, 1.75 ns, 1.15 ns
Input impedance 1 MΩ ± 2% with 9 pF ± 2 pF (meas.)
Input sensitivity max. bandwidth in all ranges 1 mV/div to 5 V/div
ADC resolution 10 bit, up to 16 bit with high resolution decimation
DC gain accuracy offset and position = 0, maximum operating temperature change of ±5°C after self-alignment input sensitivity > 5 mV/div: ± 1.5% of full scale
input sensitivity ≤ 5 mV/div: ± 2% of full scale
Acquisition system
Realtime sampling rate 1.25 Gsample/s; 2.5 Gsample/s, interleaved
Acquisition memory standard; with R&S®RTB-K15 option 10 Msample; 20 Msample, interleaved;
160 Msample segmented memory
Max. acquisition rate 50 000 waveforms/s
(300 000 in fast segmented memory mode)
Horizontal system
Timebase range selectable between 1 ns/div and 500 s/div
Accuracy (after delivery/calibration) ±2.5 ppm
Channel-to-channel skew max. 800 ps (meas.)
Channel deskew ±500 ns
Trigger system
Standard Trigger types edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus
Optional Trigger types I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN
Trigger sensitivity with DC, AC, LF reject input sensitivity > 5 mV/div: < 0.8 div (meas.);
2 mV/div ≤ input sensitivity < 5 mV/div: < 1.5 div (meas.);
input sensitivity < 2 mV/div: < 2 div (meas.)
with HF reject all input sensitivities < 1 div (meas.)
Analysis and measurement functions
Automatic measurements  32
Cursor measurements 4
Waveform mathematics  5 equations math on math (addition, substraction, multiplication, division, square, square root, abs. value, reciprocal, inverse, common log,, natural log., derivative, integral, low pass, track unipolar + bipolar on period, frequency, pulse width, duty cycle) 
Mask testing
Mask definition elementary (tolerance mask around the signal)
History and segmented memory
Number of segments up to 13 107
Protocol trigger and decode
Supported protocols I2C, SPI, UART/RS-232/ RS-422/RS-485, CAN, LIN
Waveform generator
Resolution 14-bit
Sample rate 250 Msample/s
Amplitude high-Z; 50 Ω 20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp)
DC offset high-Z; 50 Ω ±2.5 V; ±1.25 V
Arbitrary sampling rate; memory depth max. 10 Msample/s; 16k point
Logic analyzer (MSO) functionality
Digital input channels 16
MSO Memory depth 10 Msample for every channel
MSO Bandwidth 300 MHz (meas.)
MSO sampling rate 1.25 Gsample/s
MSO input impedance 100 kΩ ± 2 % || ~4 pF (meas.) at probe tips
Parallel buses up to 2
General data
Dimensions W × H × D 390 mm × 220 mm × 152 mm
(15.4 in × 8.66 in × 5.98 in)
Weight 2.5 kg (5.5 lb)
Display 10.1" WXGA TFT color display (1280 × 800 pixel)
Interfaces USB host with MTP, USB device, LAN, powerful web server for remote display and operation
Operating system Embedded

Available options

General
Product
Description

Order number 1333.1105.02

Description

Mixed signal upgrade for non-MSO models, 300 MHz

Turns the R&S®RTB2000 oscilloscope into fast, precise and easy-to-use mixed signal oscilloscopes (MSO).

R&S®RTB-B6

Order number 1333.1111.02

Description

Arbitrary waveform generator

Adds an 25 MHz signal generator and a 4-bit pattern generator to your R&S®RTB2000 oscilloscope

Serial triggering and decoding
Product
Description

Order number 1333.1011.02

Description

I²C/SPI serial triggering and decoding

Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses

Order number 1333.1028.02

Description

UART/RS-232/RS-422/RS-485 serial triggering

Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses

Order number 1333.1034.02

Description

CAN/LIN serial triggering and decoding

Triggering and decoding of CAN and LIN interfaces

General analysis
Product
Description

Order number 1333.1040.02

Description

History and segmented memory

History and 160 Msample segmented memory

Order number 1335.8007.02

Description

Frequency Response Analysis (Bode plot)

The R&S®RTB-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio.

General accessories
Product
Description
R&S®RTB-Z1

Order number 1333.1728.02

Description

Front cover

Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000

R&S®RTB-Z4

Order number 1335.9290.02

Description

Transit case with wheels for R&S®RTB

R&S®RTB-Z3

Order number 1333.1734.02

Description

Soft bag

Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories

R&S®ZZA-RTB2K

Order number 1333.1711.02

Description

19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU

Order number 1335.7875.02

Description

Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes

Passive probes
Product
Description

Order number 1803.1001.02

Description

Passive probe, 300 MHz, 10:1

Order number 1333.2401.02

Description

Passive probe, 500 MHz, 10:1

Order number 1409.7550.00

Description

Passive probe, 500 MHz, 10:1

Order number 1333.1370.02

Description

Passive probe, 38 MHz, 1:1

High voltage probes
Product
Description

Order number 1333.0873.02

Description

250 MHz passive high voltage probe

Order number 1409.7720.02

Description

400 MHz passive high voltage probe

Order number 1409.7737.02

Description

400 MHz passive high voltage probe

Logic probes
Product
Description
R&S®RT-ZL03

Order number 1333.0715.02

Description

300 MHz logic probe, 8 channels

Probe accessories
Product
Description

Order number 1333.0850.02

Description

AC/DC 20 kHz current probe

Order number 1333.0844.02

Description

100 kHz current probe

Order number 1409.7750K02

Description

10 MHZ current probe

Order number 1409.7766K02

Description

100 MHZ current probe

Order number 1409.7772K02

Description

120 MHz current probe

Order number 1801.4932.02

Description

120 MHz current probe

Order number 1409.7789.02

Description

Power supply for probes

Power supply for R&S®RT-ZC10/20/30/31 probes, +/-12V DC, +/-2.5A

Application bundles
Product
Description
R&S®RTB-PK1

Order number 1333.1092.02

Description

Application bundle (R&S®RTB-K1, -K2, -K3, -K15, -K36 and -B6)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTB-K1), UART/RS-232/RS-422/RS-485 (R&S®RTB-K2) and CAN/LIN (R&S®RTB-K3), history and segmented memory (R&S®RTB-K15), frequency response analysis (R&S®RTB-K36), arbitrary generator (R&S®RTB-B6) for R&S®RTB2000 models

R&S®RTB2000 - Media center

RTB2000 - 10 bit ADC
10 bit ADC to see small signal details in the presence of large signals
RTB2000 - 10 Msample memory
10 Msample memory to capture more time at full bandwidth
RTB2000 - high-resolution capacitive touchscreen
10.1" high-resolution capacitive touchscreen with gesture support

Also interesting for you

Rocket Science AG - Case Study

Active noise control in daily operation – Rocket Science uses state-of-the-art active noise control and a Rohde & Schwarz oscilloscope to combat irritating noise.

Download now

Oscilloscope and probe fundamentals

Learn about basic oscilloscope operation, probes as well as various oscilloscope related applications that help you optimize your measurement results.

More information

Oscilloscopes promotion

Choose the right R&S promotion for your individual needs and save your budget

More information

Oscilloscope webinar center for digital design and power electronics applications

More information

Up to 50% more savings on Rohde & Schwarz Oscilloscopes for educational customers

More information

10 years of Rohde & Schwarz oscilloscope innovation

More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.