History & segmented memory software

General analysis

History & segmented memory software
Open Lightbox
History & segmented memory software
Open Lightbox
History & segmented memory software
Open Lightbox
History & segmented memory software
Open Lightbox
History & segmented memory software, Software History & segmented memory software, Screenshot History & segmented memory software History & segmented memory software

Key facts

  • Analyze past acquistion before the error occurred
  • Substantially deeper memory on embedded oscilloscopes
  • Higher update rate in ultra-segmented mode

Oscilloscope software

The history and segmented memory function is standard of R&S®RTA4000, R&S®RTE and R&S®RTO and optional on R&S®RTB2000, R&S®RTM3000 and R&S®Scope Rider. You can scroll through past acquisitions and analyze the data using all oscilloscope tools, e.g. protocol decode and logic channels. In ultra-segmented mode, waveforms are seamlessly captured before visualization. Serial protocol and pulse sequences are recorded practically without interruptions.

Features & benefits

Analyze past acquistion before the error occurred

The history function ensures that previous waveforms stored in memory can always be accessed. A trigger timestamp allows time correlation. You can view all saved signals and analyze them with tools such as zoom, measurement, math and spectrum analysis functions

RTO2000 history mode
Open Lightbox

RTO2000 history mode

Substantially deeper memory on embedded oscilloscopes

On the embedded oscilloscopes, the history and segmented option increases the available memory substantially

  • R&S®RTB2000: 20 Msample standard to 160 Msample in sgemented mode
  • R&S®RTM2000: 20 Msample standard to 460 Msample in sgemented mode
  • R&S®RTH ScopeRider: 500 ksmaple to 25 Msample

Open Lightbox

Higher update rate in ultra-segmented mode

In the ultra-segmented mode, the minimum blind time is diminished. Serial protocol and pulse sequences can be recorded practically without interruptions. In history mode, users can easily navigate – either manually or automatically – through all recorded segments and reconstruct the history thanks to very precise timestamps.

Available models

Available models
Models
Memory
Ultrasegmented mode
Base unit

R&S®RTH-K15

Order number 1326.1803.02

Memory
50 Msample
Ultrasegmented mode
Base unit

R&S®RTB-K15

Order number 1333.1040.02

Memory
160 Msample
Ultrasegmented mode
Base unit

R&S®RTM-K15

Order number 1335.8907.02

Memory
460 Msample
Ultrasegmented mode
Base unit

Related videos

RTB2000 - 10 Msample memory

R&S®RTB2000 - 10 Msample memory to capture more time at full bandwidth

The R&S®RTB2000 offers a class-leading memory depth:10 Msample per channel are available, even 20 Msample in interleaved mode.

RTM3000 - Memory Preview

R&S®RTM3000 - 40 Msample standard and 80 Msample interleaved

The R&S®RTM3000 offers a class-leading memory depth: 40 Msample per channel are available, even 80 Msample in interleaved mode.

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.