103 Results
The ground connection on the R&S®RT‑ZMxx modular multimode probes can be used to improve measurements on high-speed differential interfaces.
09-Nov-2017
This document provides an introduction to SDR as used for military radios and presents the relevant T&M solutions offered by Rohde & Schwarz.
15-Sep-2012 | AN-No. 1MA206
Measure and analyze signals with the R&S®FSW Signal and Spectrum Analyzer platform in collaboration with an R&S®RTO Digital Oscilloscope.
16-Jun-2015 | AN-No. 1EF92
Rohde & Schwarz Realtime deembedding with the R&S®RTP
25-Sep-2018
The objective of this paper is to evaluate the performance of a power supply using an oscilloscope. The main measurements taken are the input frequency, output voltage, output current, and the switching frequency.
26-Nov-2013 | AN-No. 1TD04
The objective of this paper is to evaluate the performance of a power supply using an oscilloscope. The main measurements taken are the input frequency, output voltage, output current, and the switching frequency.
26-Nov-2013 | AN-No. 1TD04
This application note focusses on signal measurement using the R&S®RTO digital oscilloscopes ant the output of I/Q data for processing.
18-Oct-2016 | AN-No. 1MA249
RMS is one of the most common parameters in test and measurement. Mathematically, it is the quadratic mean of continuously varying values (waveform). R&S RTM-K32 option provides a digital RMS conversion function for a high-bandwidth RMS measurement.
17-Aug-2015
Correlated time-frequency measurements help optimize gate driving and minimize electromagnetic emissions early on during development.
27-Apr-2023
Generating models with a VNA and using these on an oscilloscope via the deembedding
23-May-2023 | AN-No. 1SL393
The Rohde & Schwarz oscilloscope R&S®RTO2064 with powerful FFT analysis is great for EMI debugging and a low cost solution for R&D testing.
14-Jan-2021
Correlated time-frequency measurements help optimize gate driving and minimize electromagnetic emissions early on during development.
22-Nov-2018
This document describes a method to separate common-mode and differential-mode separation using two oscilloscope channels. This separation approach works without any additional hardware component.
17-Sep-2020 | AN-No. GFM353
With the RTO-K17/RTE-K17 High Definition Option the user will see more signal details with up to 16 bit vertical resolution.
13-Apr-2015 | AN-No. 1TD06
This application note describes how to measure the control loop stability of switch-mode power supplies to get the best performance and confidence of the design.
01-Jul-2019 | AN-No. GFM321
For system verification and debugging, eye diagram measurements are the most important tools for efficiently analyzing the signal integrity in any digital design
19-Feb-2019
Thanks to their multichannel capability, oscilloscopes are ideal for multichannel applications such as the analysis of MIMO, multi-antenna radar and differential high-speed digital signals.
06-May-2020
This application note describes the basic frequency filter measurements that are often required during service repairs, during development and for training purposes.
27-Mar-2015 | AN-No. 1MA243
This application note provides an introduction to the DDR memory technology and explains common challenges, related to the specific nature of DDR data, command and control buses.
30-Oct-2020 | AN-No. GFM340
This application note introduces the reader to the SpaceX Hyperloop Pod Competition project and their special demands for the electrical drive train.
31-Mar-2021 | AN-No. GFM360
Transient Measurements on GSM/PCN Synthesizers
03-Jun-1998 | AN-No. 1EF08
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
EMI debugging using fast FFT with MXO oscilloscopes
07-Feb-2024
Rohde & Schwarz offers a powerful tool for remote control of their oscilloscopes - the RsInstrument Python module. This module enables users to control and automate their Rohde & Schwarz test & measurement instruments, including oscilloscopes, through Python scripts or interactive console communication.
14-Dec-2023
Learn more about the the two key benefits of oscilloscopes with deep acquisition memory in this application card.
13-Dec-2017
In addition to the generic edge trigger, modern oscilloscopes offer triggers that are specialized to address specific problems.
04-Jan-2016
Easy power sequencing and ripple noise analysis with MXO oscilloscopes
22-Apr-2024
With the R&S ® RTB2000 digital oscilloscopes, you control and interact remotely via LAN. These oscilloscopes incorporate the USB-based connectivity standard media transfer protocol (MTP).
20-Mar-2017
Use R&S®RTP high-performance oscilloscopes and the R&S®VSE-K6A phased array measurement option for analyzing deceptive jamming techniques and automating jamer testing.
12-Jul-2021