396 Results
Measure and analyze signals with the R&S®FSW Signal and Spectrum Analyzer platform in collaboration with an R&S®RTO Digital Oscilloscope.
16-Jun-2015 | AN-No. 1EF92
This application note describes how to use the R&S®RTO, R&S®RTE and R&S®RTM Digital Oscilloscopes for EUT monitoring of signal forms.
20-Apr-2015 | AN-No. 1MA242
Models: R&S®RTO2002, R&S®RTO2004, R&S®RTO2012, R&S®RTO2014, R&S®RTO2022, R&S®RTO2024, R&S®RTO2032, R&S®RTO2034, R&S®RTO2044, R&S®RTO2064
Measuring RDS(on) with high-definition oscilloscopes - Application Brochure
19-Mar-2015
It is recommended to use jitter measurement instruments for both the time and frequency domain in order to differentiate between fast and slow moving artifacts.
22-Aug-2017
Near Field Communication (NFC) Technology and Measurements
03-Jun-2013 | AN-No. 1MA182
R&S®RTO6示波器值得信赖。这款高级实验室设备专用于提供可靠结果,能够快速解决测量问题,确保按时完成任务。R&S®RTO6示波器利用专业的工程技术,能够随时根据需要提供深度解析,让测量更加值得信赖。
R&S RTO2000 oscilloscope Sales – Easy triggering and decoding in one software option bundle. - Flyer
The numerous supply voltages of FPGAs, CPUs and DSPs need to be powered-up in a specific order to ensure reliable operation.
08-Oct-2018
Thanks to their multichannel capability, oscilloscopes are ideal for multichannel applications such as the analysis of MIMO, multi-antenna radar and differential high-speed digital signals.
06-May-2020
This application note describes two test solutions from R&S® to cope with the 5G FR1 downlink MIMO signal analysis challenges either using R&S®RTP/RTO oscilloscope or R&S®NRQ6 frequency selective power sensor.
26-Jun-2020 | AN-No. GFM343
The R&S®RTO Oscilloscope supports the acquisition and the detailed signal analysis of these signals by using the history mode. The history mode allows the user to look back to previous acquisitions and apply the wide set of analysis functions of the RTO.
03-Jun-2013 | AN-No. 1TD02
I want to export the waveform data of my RTO scope into MATLAB, but the only way I found so far is the screenshot option. Is there another way to use the trace data in my script?
This application note introduces the working principles of a conventional trigger system and explains the advantages of the real-time capable digital trigger of the RTO oscilloscopes.
11-Apr-2012 | AN-No. 1ER04
This application note presents the Jitter analysis capabilities of the R&S®RTO for digital signals. It demonstrates the basic operation with an application example, and shows the associated jitter analysis.
29-Aug-2013 | AN-No. 1TD03
R&S RTO/R&S RTP USB 2.0/3.2 Compliance Test User Manual. The user manual describes the USB 2.0 compliance test procedures.
This application note explains the background of blind time and points out why a high acquisition rate is important. It furthermore explains the R&S RTO oscilloscope capabilities and how they help for faster debugging, measurement and analysis.
17-May-2011 | AN-No. 1ER02
Differential measurements with Spectrum Analyzers and Probes
28-Jun-2013 | AN-No. 1EF84
Rohde & Schwarz "Getting Started" for R&S RTO digital oscilloscopes.
Instrument Security Procedures for R&S® RTO2000
Rohde & Schwarz user manual for the R&S RTO digital oscilloscopes including options R&S RTO-K1, K2, K3, K4, K5, K6, K7, K8, K9, K10, K11, K12/13, K17, K31, K40, K50, K52, K55, K60, K65, B1
Programming examples for oscilloscopes.
Models: R&S®RTO2002, R&S®RTO2004, R&S®RTO2012, R&S®RTO2014, R&S®RTO2022, R&S®RTO2024, R&S®RTO2032, R&S®RTO2034, R&S®RTO2044, R&S®RTO2064
The Zoom function does not show any waveform data at specific settings, especially at slower timebases in combination with higher sample rates, High resolution and roll mode with more channels. The problem is gone if a lower sample rate is chosen.
Ethernet communications has been introduced in automotive networks to enable fast and cost efficient data communications.
27-Mar-2015
01-Jul-2021
New R&S RTO6 oscilloscopes from Rohde & Schwarz deliver instant insights thanks to enhanced usability and performanceRohde & Schwarz takes its successful R&S RTO family to the next level with the all-new and redesigned R&S RTO6 oscilloscope. Featuring an updated user interface on a larger, 15.6-inch Full HD touchscreen and straightforward workflows, it speeds up daily measurement tasks. The R&S RTO6 delivers deep insights into designs on the engineer's workbench with state-of-the-art specifications such as an outstanding 9.4 ENOB, an unparalleled update rate of one million waveforms per second as well as a comprehensive toolset of analysis functions.
For measurement settings below 10 mV/div, oscilloscopes typically reduce the measurement bandwidth in order to keep the trace noise as low as possible. The R&S®RTO is different: It offers the full bandwidth even for the most sensitive settings, and an A/D converter with more than 7 effective bits (ENOB) digitizes the signal.
13-Jul-2012
Equipped with the R&S®RTO-K11 I/Q software interface option, the R&S®RTO provides the I/Q data of the acquired signals to the external R&S®FS-K10xPC LTE analysis software for demodulation and detailed analysis. video, LTE, MIMO, FS-K10xPC, RTO, RTO-K11 Rohde & Schwarz at EuMW 2012: Up to 4 LTE MIMO antenna signal analysis with one oscilloscope
This application note describes the possibilities to measure LTE MIMO with the LTE-Software R&S®FS-K102/K103PC in combination with an R&S®RTO1044 oscilloscope.
24-Apr-2013 | AN-No. 1EF86
The application fields of oscilloscopes extend to EMI debugging because of their powerful and easy-to-use FFT analysis capabilities– and save time and money.
23-Sep-2019