Key facts
- Max. output power: 100 W
- Max. voltage per channel: 32 V
- Max. current per channel: 3 A, 5 A or 10 A
- Galvanically isolated, floating and short-circuit proof outputs
- Intuitive, price-transparent online product configurator
Key facts
R&S®NGC100 DC power supplies are very energy efficient, remaining cool and quiet, even at maximum load. Practical interfaces and connectors make work quick and convenient while special applications have comfort functions. One, two, or three channels – a wide range of functions and fundamental specifications make R&S®NGC100 DC power supplies ideal for:
-Development labs
-Industrial environments
-Manufacturing
-Education
You can now use the new online configurator to quickly design your R&S®NGC100 DC power supply with full price transparency. Get your request processed in no time by the authorized distribution partner of your choice.
Electrical specifications | |
Number of output channels | 1 / 2 / 3 |
Total output power | max. 100 W |
Maximum output power per channel | 100 W/50 W/33 W |
Output voltage per channel | 0 V to 32 V |
Maximum output current per channel | 10 A/5 A/3 A |
Voltage ripple and noise (20 Hz to 20 MHz) | R&S®NGC101: < 1 mV (RMS) R&S®NGC102/103: < 450 µV (RMS) |
Current ripple and noise (20 Hz to 20 MHz) | R&S®NGC101: < 1.5 mA (RMS) (meas.) R&S®NGC102/103: < 1 mA (RMS) (meas.) |
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) | < 1 ms (meas.) |
Programming resolution voltage | 1 mV |
Programming resolution current | < 1 A: 0.1 mA (R&S®NGC101: 0.5 mA) ≥ 1 A: 1 mA |
Output measurements | |
Readback resolution voltage | 1 mV |
Readback resolution current | < 1 A: 0.1 mA (R&S®NGC101: 0.5 mA) ≥ 1 A: 1 mA |
Readback accuracy voltage ±(% of output + offset) | < 0.05 % + 2 mV |
Readback accuracy current ±(% of output + offset) | typ. < 0.05 % + 4 mA (R&S®NGC101: typ. < 0.15 % + 10 mA) |
Special functions | |
Measurement functions | voltage, current, power, energy |
Protection functions | OVP, OCP, OPP, OTP |
FuseLink function | ● |
Fuse delay at output-on | ● |
Sense function | ● |
Sink mode | - |
Output sequencing | ● |
External trigger | ● |
Arbitrary function | ● (EasyArb) |
Analog/modulation interface | ● |
Data logging | ● |
Display and interfaces | |
Display | 3.5" QVGA |
Rear panel connections | Connector block with 4 lines per channel |
Remote control interfaces: standard | USB, LAN; R&S®NGC100-G models with IEEE-488 (GPIB) |
General data | |
Dimensions (W × H × D) | 222 mm × 97 mm × 291 mm |
Weight | 2.6 kg |