Key facts
- Partial export of recorded I/Q data
- Continuous Playback of recorded I/Q data
- Post-processing with R&S®VSE Vector signal explorer
Key facts
The R&S®IQW wideband I/Q data recorder is a versatile instrument for fast and reliable realtime recording, storage and playback of wideband I/Q data streams. In contrast to field tests, recording of live RF scenarios allows users to perform tests in the lab under real-world conditions reproducibly and at lower cost
Quick links
High-precision data acquisition
The new R&S®IQW provides excellent performance while ensuring easy operation. High resolution allows tests under real world conditions.
15 Tbyte SSD memory pack
With the R&S®IQW-BD115 option you will get a server-grade SSD memory pack with 15 Tbyte storage capacity. This memory pack is supporting the recording and replaying process up to 1000 MHz. When using the maximum bandwidth of 1000 MHz, the R&S®IQW reaches approximately 65 minutes of recording time. The maximum recording time is increased by reducing the selected bandwidth. There are additional SSD memory packs available in 3,2 Tbyte and 6,4 Tbyte.
Recording time as a function of data rate
The system makes the difference
The R&S IQW is a versatile I/Q wideband recorder, that can be used with various R&S instruments. The signal and spectrum analyzer R&S®FSW and signal generator R&S®SMW200A is support for high-end applications. Furthermore the operation with R&S®SMBV100B and R&S®SGT100A is supported.
Record and replay wizard for easy and fast operation
The innovative GUI of the R&S®IQW ensures an easy handling of the recording and replay process. The R&S IQW has a user-optimized and clean GUI that gives a structured overview over the device properties and functionalities. Coming from a user perspective, the wizard is guiding you step-by-step through the recording and replaying process. This allows the user a fast, easy and intuitive operation of the device.
Order number 1525.7551.02
Order number 1525.7551.05
Order number 1525.7551.10
I/Q data transfer | ||
RF bandwidth | in combination with R&S®FSW and/or R&S®SMW200A | 1000 MHz |
I/Q word size | per I/Q sample | Depending on bandwidth 12 or 16 bit for I and Q |
Sampling rate | R&S®IQW | 1200 Msample/s (oversampling factor 1.25/Hz), complex |
HS Digital I/Q interface | full duplex, QSFP+, 40 Gbit/s | |
Interfacing instruments | I/Q data source for recording | R&S®FSW, R&S®FSWT |
Q data sink for playback | R&S®SMW200A, R&S®SMM100A, R&S®SMBV100B, R&S®SGT100A | |
General data | ||
Display | with touchscreen | 5.7" TFT color display, 640 × 480 pixel, LED backlighting |
USB interfaces | 4 × USB 2.0, 3 × USB 3.0 | |
LAN interface | remote control | Ethernet 10/100/1000 Mbit/s |
Power supply | AC power supply | 100 V to 240 V AC (±10 %), ≤ 150 VA, 50 Hz to 60 Hz/400 Hz (±5 %), 1.5 A to 3.6 A |
Overall dimensions | W × H × D | 249 mm × 150 mm × 451 mm (9.80 in × 5.90 in × 17.76 in) |
for 19" rack mounting | ½ 19", 3 HU | |
Weight | 6.3 kg (25.4 lb) | |
Environmental conditions | operating temperature range | 0 °C to +40 °C |
storage temperature range | –20 °C to +70 °C |
Order number 1525.8293.03
3.2 Tbyte SSD memory pack, for maximum RF bandwidth of 200 MHz
Order number 1525.8293.06
6.4 Tbyte SSD memory pack, for maximum RF bandwidth of 1000 MHz
Order number 1525.8293.15
15 Tbyte SSD memory pack, for maximum RF bandwith of 1000 MHz
Order number 3641.2948.03
Cable for HS digital I/Q interface, 3 m
Order number 1415.0201.02
Cable for standard I/Q Interface, 2 m
Order number 1525.7574.02
R&S®IQW 19 Zoll Rackadapter
Order number 1525.8264.02
Interface board with 2x10 Gbit/s and 40 Gbit/s
Order number 1525.8370.02
Import and export of I/Q data
Order number 1525.8393.02
Recording of GPS Coordinates
Order number 1525.8429.02
Bandwidth extension up to 200 MHz for R&S®IQW100