Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1110 Results
The R&S®SMW-K546 software option aids the optimum design of multiple path amplifiers, including Doherty Amplifiers.This application note provides guidance on the use of the software option, both for direct control and programming via the touchscreen, and for remote control using SCPI.The software and associated techniques may similarly be used to develop other quasi-linear, multi-path amplifiers; including Balanced, Anti-Phase (so-called Push-Pull), Distributed, Spatially Combined, Load Modulated Balanced and many more.
13-Jul-2020 | AN-No. GFM345
Primer
A power sensor is a fundamental measurement tool in RF engineering. However, today's marketplace is filled with myriad choices, and many are making bold claims about attributes such as measurement speed and readings per second. As a result, it can be difficult to cut through the hyperbole and determine which sensor will actually meet the requirements of a specific measurement.This primer outlines the basics of RF power sensors and highlights a few key characteristics that will help you select the best one for each application. The narrative has three parts. First, we focus on choosing the right type of sensor: multipath, wideband, average power and thermal can satisfy slightly different measurement needs. The second section covers the five major attributes of sensor performance, and what to look for relative to your requirements. Finally, we outline three ways to integrate a sensor into your measurement application.
26-May-2021
Road safety is a global challenge at present and will be in the future. Automotive radar has become a keyword in this area and pushes again a step forward to increase driving comfort, crash prevention and even automated driving.Driver assistance systems which are supported by radar are already common. Most assistant systems are increasing the drivers comfort by collision warning systems, blind-spot monitoring, adaptive cruise control, lane-change assistance, rear cross-traffic alerts and back-up parking assistance.Today's 24 GHz, 77 GHz and 79 GHz radar sensors clearly need the capability to distinguish between different objects and offer high range resolution. That is possible with increased signal bandwidth.Furthermore, those radar systems need to cope with interference of many kinds like the one from other car's radar.This Application Note addresses signal measurements and analysis of automotive radars that are crucial during the development and verification stages. It also shows a setup to verify the functionality of a radar in case of radio interference.
10-Jun-2016 | AN-No. 1MA267
Verify and optimize your product design under realistic fading conditions in a deterministic lab environment that allows repeatable measurements using standardized and user-defined fading profiles.
27-Oct-2020
With the R&S®Pulse Sequencer radar simulation software, users can easily and intuitively create scenarios for simulation of angle of arrival (AoA). Together with multiple coupled R&S®SMW200A vector signal generators, this solution allows quick and thorough performance characterization of all types of direction finding equipment such as devices that use amplitude comparison, interferometric or time difference of arrival (TDOA) techniques. This document describes our test solution for testing devices that use amplitude comparison techniques.
02-Apr-2020
Phase difference is the key parameter when characterizing direction finding (DF) scenarios. To analyze DF equipment, the phase difference needs to be determined before measuring other parameters such as the bearing. The R&S®VSE-K6A multichannel pulse analysis software in combination with a Rohde & Schwarz oscilloscope provides phase difference measurements even in challenging environments, utilizing the test equipment’s advanced trigger capabilities.
02-Mar-2021
EMI compliance is becoming a major concern for advanced power electronics due to increasing switching speeds. Correlated time-frequency measurements help optimize gate driving and minimize electromagnetic emissions early on during development.
27-Apr-2023
Today’s digital designs and high-speed data converters require clean clocks with minimal jitter
03-Aug-2017
R&S®NRPView has been replaced by software Power Viewer Plus, which is provided together with software R&S®NRP Toolkit.Please use the link given below to download R&S®NRP Toolkit.
18-Dec-2008 | AN-No. 1MA77
Getting started with IQ Streaming Application
The intention of this Application Note is to provide an overview of all necessary tasks for getting along with successful IQ Streaming.The necessary technical requirements are described as well as the streaming parameters of the IQ data stream.The general operation and basic setup of the MSR4 is described in the user manual and is not part of this document.
28-Mar-2023 | AN-No. 1179.7104.02
based on SCPI command sequences
MINX – the Measurement Instrument Network eXplorer – is a fast, non-invasive discovery and configuration software from Rohde & Schwarz for LAN and USB T&M instruments.Agnostic of instrument model or manufacturer, MINX provides an intuitive graphical user interface with access to powerful configuration, control, results collection and remote display functions.Test or research engineers can quickly setup a collection of instruments to initialise, measure and download results. Universities can configure and manage many instruments together, copying instruments and saving class setups.Besides these core functions, MINX provides an extension mechanism making even more sophisticated instrument operations available by just the click of a single button. Such extended functions are SCPI-based command sequences which can be added by the user on a per-instrument basis and require no software update.This application note describes the different kind of extendable function groups. It will be pointed out how extended functions can be added or edited and which format the script must comply in order to get directly available in MINX.
12-Jan-2021 | AN-No. GFM344
This application note describes a software application that can be utilized in conjunction with Rohde&Schwarz Signal- and Spectrum Analyzers and Signal Source Analyzers to capture and analyze transient signals. The software application takes advantage of the instrument’s IQ memory buffer of up to 705 Msamples to capture and analyze IQ signals in the time domain and / or frequency domain. This is useful for measuring lock time, analyzing radar pulses, finding spurious transients, and other measurements similar in nature to these. This application can be used with R&S®Signal Source Analyzer FSUP and R&S®Signal and Spectrum Analyzers FSQ, FSU, FSG, FSV.
16-Feb-2009 | AN-No. 1MA141
Receiver diversity improves reception quality by using multiple antennas with a preferably low correlation factor between each other. This results in a more robust handling of multipath signals, since a deep fade will then not affect all received signals at the same time. However, the compact dimensions of handheld devices can introduce unwanted correlation due to their dense antenna spacing. In this case, the popular diversity test setup consisting of several independent transmitters will no longer serve the needs of a realistic simulation, since correlation effects have to be taken into account here. A clever solution is to operate the R&S®SFU in split-fading mode in combination with a second transmitter. This can be another R&S®SFU, the R&S®SFE, the R&S®SFE100 or the R&S®SMU200A. In this way, two diversity signals of adjustable correlation for any common broadcast standard are coded in realtime, while their individual multipath profile is precisely specified by the extensive features of the R&S®SFU fader module.
19-Oct-2012 | AN-No. 7BM76
World’s first fully electronically steerable antenna array.
27-Jun-2023
- not available -
20-Jul-2001 | AN-No. 7BM13
EMI Automotive Band Evaluation extension is an on-board EMI measurement sequence in broadband and communications frequency bands for automotive and aerospace applications. This application notes shows how to configure, run, and automatically document tests in a sequence coming with EMC32-K51.
17-Jul-2014 | AN-No. 1SP07
Today, digital audio signals are transmitted via standardized interfaces not only in the form of continuous data streams but also increasingly as burst audio signals. This application note shows various ways of generating and analyzing such data bursts with Audio Analyzer UPD. In the applications described, the parameters word clock, bit clock and word length can be set over wide ranges. Single-channel and dual-channel audio data with bit clocks far into the MHz range can be processed.
05-Nov-1997 | AN-No. 1GA38
The present application note describes the possibilities of the Stream Explorer to be remotely controlled by some peripheral program via OLE. Extensions are also discussed, widening the fields of application of such a Client-Server architecture.
31-Mar-1999 | AN-No. 7BM02
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many listeners. A single instrument, the R&S®ETL TV analyzer, performs all required DAB transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.
24-Jul-2013 | AN-No. 7BM104
This application note is a programming guide. It briefly summarizes basic tips and information about SCPI programming for remote-controlling Rohde & Schwarz signal generators.
26-Apr-2013 | AN-No. 1GP79
1TD04 1TD04, DC/DC, Oscilloscopes The objective of this paper is to evaluate the performance of a power supply using an oscilloscope. The main measurements taken are the input frequency, output voltage, output current, and the switching frequency. Initial Evaluation of a DC/DC Switch Mode Power Supply 1TD04 1TD04, DC/DC, Oscilloscopes The objective of this paper is to evaluate the performance of a
26-Nov-2013 | AN-No. 1TD04
Due to today’s worldwide highly competitive communications market, achieving shorter product design cycles, quicker response to customer requests and high-volume product runs at low costs is vital for manufacturers of wireless devices and components. These requirements inevitably lead to demands for improving the throughput of Automated Test Equipment (ATE) by increasing its speed. This application note describes in detail how the special features of the R&S® SMATE200A can be used to optimize speed and throughput in an automated test environment.
17-Apr-2007 | AN-No. 1GP63
Rohde & Schwarz offers unique one-box solutions for reliable testing of air navigation systems such as ILS, VOR and DME.
04-Nov-2010
This application note describes how to configure a Rohde & Schwarz Network Analyzer to make spectral measurements directly on a device under test.
16-Mar-2012 | AN-No. 1EZ62
- not available -
20-Jul-2001 | AN-No. 7BM25
Emergency Call (eCall) is a service provided in Europe with the goal of reducing response times for accidents or other emergencies on the roadways. This application note briefly describes the technology behind eCall and presents conformance tests for eCall using the R&S®CMW500 RF tester and the R&S®SMBV100A vector signal generator. A Test software for eCall makes it quick and easy to perform these tests with the GSM or WCDMA wireless communications standard. It also shows a test solution for GNSS performance tests for eCall using the R&S®SMBV100A vector signal generator and the option R&S®SMBV-K361 together with CMWrun.This application note is outdated. We therefore refer to the newer application note .
24-Jan-2018 | AN-No. 1MA241
Frequency Modulated Continuous Wave (FMCW) radar signals are often used in short range surveillance, altimeters and automotive radars. To ensure proper functionality, signal quality measures such as frequency linearity are of great importance.This application note focuses on fully automated, fast and accurate measurements, of linear FMCW radar signals. It explains the basic signal processing, the impact on radar key performance indicators in case of linearity deviations and explains test and measurement of linear FMCW signals in detail.Measurement of an FMCW radar signal in the 77-81 GHz band with 500 MHz of measurement bandwidth is demonstrated.
25-Apr-2014 | AN-No. 1EF88
This white paper describes the basic functionality of antennas. Starting with Hertz's Antenna model followed by a short introduction to the fundamentals of wave propagation, the important general characteristics of an antenna and its associated parameters are explained. A more detailed explanation of the functionality of some selected antenna types concludes this white paper.
04-Nov-2014 | AN-No. 8GE01
Determining the noise figure of a component can be difficult in unshielded lab environments. Measuring small noise figures (less than 3 dB) and reproducing the results is sometimes not possible. These difficulties are caused by interference effects (electric fields) that can occur in any environment. A suitable remedy is a measurement environment able to shield the Device Under Test (DUT) against all interfering fields in the range up to 3 GHz. When used in conjunction with a spectrum analyzer and Noise Measurement Software FS-K3, the Shielded Box ZA-SB10 provides a complete noise measurement system.
16-Oct-2002 | AN-No. RSH01