Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
734 Results
A programmable data generator such as the combination of SME with option SME-B11 is a novelty with signal generators. To make it easy for the user to get acquainted with the option and to ensure efficient operation, possible applications are described below. The data generator is used for producing binary data as well as control signals for level switching whenever digitally modulated signals are used. For a start we should like to deal in brief with the various settings available for digital modulation. Taking GSM as an example, the programming of data lists will be described next. The description for GSM can be easily applied to other digital networks as well. Next the generation of level bursts and the extension of data generator memory with option SME-B12 are described. The last section deals with special subjects such as FSK using data rates below 400 bits/s and pulse-amplitude modulation. A basic knowledge on digital modulation and TDMA will be sufficient to follow the topics.
01-Jul-1999 | AN-No. 1GPAN08
The application note describes the Measurement Uncertainty Analysis Program NRV-Z. The program is used to determine measurement uncertainties that inevitably arise when using power meters. In particular, it covers the NRV-Z family of thermal sensors and diode sensors for high-precision power measurements, as well as the compatible basic units NRVD, NRVS and URV55.
26-Jul-2001 | AN-No. 1GP43
This application note shows all necessary settings for performing Dual Receiver Measurement using the R&S®EMC32-K27 option via R&S® EMC32 Measurement Software.
28-Sep-2017 | AN-No. 1SP20
This application note outlines two different approaches for remote-controlling Rohde & Schwarz instruments out of MathWorks MATLAB:The first one uses VISA connection and direct SCPI commands.The second approach takes advantage of Rohde & Schwarz VXI plug&play instrument drivers and MATLAB Instrument Control Toolbox.
12-Jun-2017 | AN-No. 1MA171
This Application Note describes measurements compliant with the CDMA2000® base station standard described in 3GPP2 C.S0010-C v2.0 / TIA/EIA-97-F-1. The primary focus is on solutions for generating and analyzing CDMA2000® signals. The special characteristics that make the selected signal generators and signal analyzers highly suitable for this purpose are detailed, and remote control programming is demonstrated by means of a free-of-charge program.
15-Sep-2009 | AN-No. 1MA109
This application note highlights various aeronautical radio navigation signals such as VHF omnidirectional radio range (VOR), instrument landing system (ILS) for glide slope (GS) and localizer (LLZ), as well as marker beacon (MB). Rohde & Schwarz test and measurement solutions for avionics navigation equipment are introduced based on application scenarios, including calibration, research and development, field tests, and transceiver testing.
01-Feb-2012 | AN-No. 1MA193
This application note explains step by step all necessary settings for transmitting parameters of the disturbance signal from an EMS test to a dAV Camera System via serial port or LAN interface. The dAV Camera System overlays these parameters onto the camera signal.
10-Dec-2019
Phase distortions in a transmission channel are determined using group delay measurements, they must be as low as possible to maintain good signal quality. Vector network analyzers are normally used to characterize the group delay variations as a measure of phase distortion.This application note provides basic information about the concept of a group delay measurement with spectrum analyzers and signal generators, and how this method simplifies the test setup and improves the measurement speed.Measurement examples show the limiting factors of this approach and help the user to understand and avoid some limitations of this method. In addition the test results are compared to those generated with vector network analyzers.
09-Aug-2017 | AN-No. 1EF98
The R&S MATLAB® Toolkit for Signal Generators provides routines for remote controlling these instruments. Additional MATLAB® scripts turn I/Q vectors into the Rohde & Schwarz waveform file format for use with an ARB. This application note describes the installation and use of the R&S MATLAB® Toolkit on Microsoft Widows and Linux based systems.
26-Apr-2013 | AN-No. 1GP60
This application note describes how to use the mask and limit test features of the R&S®RTO, R&S®RTE and R&S®RTM Digital Oscilloscopes for EUT monitoring of signal forms, jitter etc. with the R&S®EMC32 Measurement Software. The mask test function allows autonomous characterization of digital signal integrity during EMS tests. R&S®EMC32 software records violations of userdefined limits or mask templates and evaluates the immunity threshold at frequencies of critical electromagnetic susceptibility.
20-Apr-2015 | AN-No. 1MA242
This application note describes how to generate cdma2000® signals for wide ranging receiver tests under fading conditions for cdma2000® 450/Cellular/PCS/IMT-2000 mobile and base station equipment. The test setup requires an Rohde & Schwarz Universal Radio Communication Tester CMU with IQ-IF interface option CMU-B17 and a baseband fading simulator ABFS. The cdma2kFadLevCor program included with this application note performs a semi automatic level correction of the power fed to the Device Under Test (DUT).
21-Jan-2005 | AN-No. 1MA64
Noise-Power-Ratio (NPR) measurements are a common procedure and a simple but useful tool to characterize the performance of power amplifiers for satellites or other multi-channel communication systems. The main advantage is the use of wideband signals like noise, multi-carrier CW tones or I/Q modulated signals, which leads to a better simulation of the real environment. This application note provides information how to generate these signals with a vector signal generator and perform NPR measurements with spectrum analyzers. With the R&S®SMW200A vector signal generator any desired test signal can be created. The R&S®FSW spectrum and signal analyzer offers an automated function for NPR measurements. The limiting factors of both a vector signal generator and a spectrum analyzer are explained. Measurement examples show the practical results of NPR measurements.
24-Jun-2019 | AN-No. 1EF108
3GPP TS25.141 defines conformance tests for W-CDMA base stations (including HSPA+ features). This application note describes how transmitter (Tx) tests (TS25.141 Chapter 6) can be performed quickly and easily by using signal and spectrum analyzers from Rohde & Schwarz. A few tests additionally require vector signal generators from Rohde & Schwarz. Example illustrates manual operation. A free software program enables and demonstrates remote operation. The W-CDMA base station receiver (Rx) tests (TS25.141 Chapter 7) are described in Application Note 1MA114.
21-Oct-2014 | AN-No. 1MA67
Air Traffic Control (ATC) radar, military Air Traffic Surveillance (ATS) radar and meteorological radar operate in S-Band frequency range. In fact 4G communication systems such as Long Term Evolution (LTE) make also use of these frequencies. Test and measurement of their coexistence is absolutely essential as performance degradation of mobile devices and networks and even malfunction of ATC radars has been proven.This application note describes LTE and S-Band radar coexistence test and measurement. It addresses LTE user equipment, base stations and S-Band radars and presents test solutions.
28-Mar-2014 | AN-No. 1MA211
This application note shows how to run 3GPP WCDMA BER and BLER tests according to standard TS 25.141 with the Vector Signal Generators R&S®SMBV100A, R&S®SMJ100A, or R&S®SMU200A. The description of hardware test setup is followed by detailed instructions on how to configure the R&S® generators and how to run a BER or BLER test step by step. Remote control commands for the generators are included, to simplify integrating the BER/BLER tests into your proprietary test suite.
06-Mar-2009 | AN-No. 1MA144
The fact that cable TV networks are generally located in densely populated areas or extend over large geographical regions makes the presence of line extenders at regular intervals a necessity. Cascading large numbers of amplifiers however calls for excellent noise, SWR and intermodulation distortion specifications for the integrated amplifiers in order to avoid quality of service dropping below minimum acceptable levels. Composite second order, composite triple beat & cross modulation are commonly used figures to specify the performance of CATV equipment. In this application note we describe how to determine these figures with the aid of R&S SMU200A or AFQ100A and SMV vector signal generators.
11-Aug-2006 | AN-No. RAC-0605-016
The SMIQB Vector Signal Generator and the AMIQ I/Q Modulation Generator with the WinIQSIM™ software are outstanding signal sources for 3rd generation communication systems. This paper describes how to apply R&S signal generators for 3GPP WCDMA measurements, and introduces 3GPP WCDMA and related measurement applications.
27-Nov-2000 | AN-No. 1GP39
A great number of measurements have to be performed to determine the quality of FM tuners. This Application Note presents a program that permits these measurements to be carried out in line with DIN EN60315-4.
11-Feb-2003 | AN-No. 1GA43
Measurement deviations due to systematic errors of a network analysis system can be drastically reduced by an appropriate system error calibration. After system error correction, the residual measurement uncertainties are - besides the stability, linearity, and dynamic range of the network analyzer system - mainly affected by the quality of the calibration standards and the repeatability of the connections. The effective measurement accuracy of the network analysis system can be determined using the results of successive verification measurements utilizing highly precise verification standards.
24-Jan-2001 | AN-No. 1EZ48
This application note provides information how to perform spectral emissionmeasurements on pulsed signals with spectrum analyzers using RBW filters with verywide bandwidth, and explains the capabilities and the limiting factors of the Rohde &Schwarz FSW signal and spectrum analyzer to perform this measurement.
06-Jun-2019 | AN-No. 1EF106
DIRECTV®, a digital TV broadcast system, makes use of transport packets with a length of 130 bytes rather than the more common 188 bytes used in MPEG TS streams. The inputs on the R&S® SFU do not accept transport streams in the DIRECTV® format. This Application Note introduces R&S® DIRECTV tool and explains how it can be used to convert existing 130-byte-based DIRECTV® transport stream content to 188-byte-based ISO 13818-1 streams that are compatible with the R&S® SFU SPI input or the internal R&S® SFU TRP player. This tool is intended for Rohde & Schwarz customers who are licensed to operate an R&S® SFU-K9 DIRECTV coder or R&S® SFU-K108 AMC coder.
05-Oct-2007 | AN-No. 7BM69
This operation guide describes how to measure HSUPA test cases according to 3GPP TS 34.121 V8.0 with R&S®CMU200. Setting files according to the test requirements are attached.
08-Oct-2009 | AN-No. RCS0712-0053
A Test Port Adapter System is implemented for all Rohde & Schwarz equipment, which operates above 26 GHz in order to protect the RF front-end from mechanical damage. The Test Port Adapter System consists of an RF front-end interface called the Test Port Adapter Body, and the Test Port Adapter Head which is attached to the Body. The Head provides an interface to a cable or device under test. This Application Note identifies the various types of Test Port Adapters, their parameters, compatibilities and usages.
28-Apr-2015 | AN-No. 1MA100
Using R&S®ELEKTRA Migration Tool
The R&S®ELEKTRA EMC test software is the successor of the R&S®EMC32 EMC measurement software. Like the R&S®EMC32 EMC measurement software, the R&S®ELEKTRA offers a solution that controls complete EMC systems and automates measurements on equipment under test (EUT) that is being tested for emissions (EMI) and immunity (EMS) compliance. It has more features and test types compared to R&S®EMC32.As both software platforms use different file formats, R&S®EMC32 users who upgrade their existing software to the R&S®ELEKTRA platform need to perform a file conversion before migrating their data to the R&S®ELEKTRA platform. This is done by using the R&S®ELEKTRA Migration Tool, which is installed automatically with each R&S®ELEKTRA installation.This Application Note describes how to use the R&S®ELEKTRA Migration Tool (version 4.4 onwards) for converting the backup data into the XML format that can be interpreted by the R&S®ELEKTRA software. It also provides recommended conversion steps (Chapter 5) and troubleshooting tips (Chapter 6). For instructions on migrating the data using R&S®ELEKTRA Migration Tool below version 4.4, refer to the R&S®ELEKTRA user manual. For better user experience, we recommend using the latest software version for migration.This Application Note does not describe the steps to backup data using the R&S®EMC32 or R&S®ES-SCAN software. For procedures on how to do so, refer to their respective manuals.
04-May-2023 | AN-No. 1SL396
Three hardware modifications of the option External Measurements ZVR-B25 enable the bidirectional network analyzers of the ZVR-family to carry out 4-port measurements. For the measurements, the four ports PORT 1, PORT 2, INPUT b1 and INPUT b2 at the front panel of the ZVR(E) are utilized. The fifth connector, ie OUTPUT a1, is not required for this purpose. As detailed below, the necessary modifications of the test set of the analyzer are described for the model ZVR. Of course, the modifications can be done in a similar way for the model ZVRE as well.
28-Jul-1998 | AN-No. 1EZ25
This application note provides information about measurements on DVB-S2 transmitters, including Amplitude Phase Shift Keying (APSK) signals. Specifically, this note will discuss how to import APSK mapping files in order to make modulation quality measurements.
09-Feb-2010 | AN-No. 1MA172
Being faced with a wide variety of standards and manufacturer’s specifications, test engineers may often find it difficult to keep track of necessary audio measurements. This is aggravated by the fact that modern audio analyzers offer a multitude of settings. This application note serves as an aid offering a collection of typical setups that make it possible to get started with measurements immediately. In addition, information is given on associated standards, on the adaptation of the setups to specific measurement tasks as well as on the evaluation of results.
04-Jun-1998 | AN-No. 1GA36
This application note describes how to measure the control loop stability of switch-mode power supplies to get the best performance and confidence of the design. It will explain the main measurement concept and will guide the user during the measurements and mention the main topics in a practical manner. Wherever possible, a hint is given where the user should pay attention to it to avoid weak measurements. The Rohde and Schwarz buck converter reference board was designed in collaboration with Texas Instruments and is used to illustrate the closed loop measurement in a practical manner.
01-Jul-2019 | AN-No. GFM321
RTC, RTC1000, Application Card, Determining current-voltage characteristics with the oscilloscope With their included component tester, the R&S®RTC1000 oscilloscopes are universally deployable in development and educational environments. Determining current-voltage characteristics with the oscilloscope RTC, RTC1000, Application Card, Determining current-voltage characteristics with the oscilloscope
20-Dec-2017
This application note reviews a new calibration subsystem which consists of Inline Calibration Units (ICUs). These ICUs are designed for in situ use, so they are left in place both during the calibration procedure and during the measurement of the Device Under Test (DUT).This adds versatility, convenience and accuracy to the VNA based measurement system, as it means the calibration can be refreshed at any time without manually disconnecting the DUT from the test system.
29-Sep-2017 | AN-No. 1EZ71