This application note provides information about measurements on DVB-S2 transmitters, including Amplitude Phase Shift Keying (APSK) signals. Specifically, this note will discuss how to import APSK mapping files in order to make modulation quality measurements.
09-Feb-2010 | AN-No. 1MA172
Spectrum and network analyzers are capable of measuring large amounts of data that require complex mathematical processing; MATLAB is a powerful tool for such operations. This application note describes how instruments can be controlled directly from MATLAB scripts and how measurement data can be imported into MATLAB. Only 32-bit MATLAB is supported.
24-Sep-2007 | AN-No. 1EF46
This Application Note describes the HSDPA uplink channel structure. Challenges for UE power amplifier design are outlined, and guidelines how to use R&S measurement equipment for testing UE power amplifiers are provided. An outlook on High Speed Uplink Packet Access (HSUPA) and the impact of HSUPA on the uplink channel structure is given.
11-Jul-2011 | AN-No. 1MA84
Testing multi carrier power amplifiers of the 3rd Generation requires test signals with a high dynamic range. This application note describes how a 4 carrier 3G WCDMA signal can be generated and measured with the application software SET_MC4. The software sets up to 4 SMIQ03HDs to generate the signal, and an FSU or FSQ to immediately evaluate and analyze the Adjacent Channel Leakage Ratio (ACLR) of the power amplifier. The setups are controlled remotely.The SET_MC4 source code is also included. Modify the code to meet your individual requirements or adopt the IEEE-commands into your own setup script.
13-Dec-2002 | AN-No. 1MA62
This application note describes the different memory types and locations that user information can be stored in a spectrum analyzer R&S® FSP, R&S® FSU or R&S® FSQ, as well as the different ways in which it can be erased/cleared for security reasons.
20-Sep-2004 | AN-No. 1EF53
This application note provides information about the ACLR measurement with noise correction. The basic requirements and the limiting factors of a spectrum analyzer are explained. Dynamic range improvements by means of a noise correction is presented. Measurement examples show the practical realisation ACLR measurements.
16-May-2002 | AN-No. 1EF49
Rohde & Schwarz recognizes the potential risk of computer virus infection when connecting Windows®-based test instrumentation to other computers via local area networks (LANs), or using removable storage devices. This white paper introduces measures to minimize malware threats and discusses ways to mitigate risks while insuring that instrument performance is not compromised. The paper discusses the use of anti-virus software, with recommended configuration settings. It also outlines how to keep the Windows® XP operating system properly updated through regular installation of OS patches.
04-Oct-2012 | AN-No. 1EF73
This application note provides information about the spurious emission measurement on 3 GPP base station transmitters. The basic requirements and the limiting factors of a spectrum analyzer are explained in detail. Dynamic range calculations with measurement examples show the practical realisation of spurious emission measurements.
10-Jan-2002 | AN-No. 1EF45
This application note highlights various aeronautical radio navigation signals such as VHF omnidirectional radio range (VOR), instrument landing system (ILS) for glide slope (GS) and localizer (LLZ), as well as marker beacon (MB). Rohde & Schwarz test and measurement solutions for avionics navigation equipment are introduced based on application scenarios, including calibration, research and development, field tests, and transceiver testing.
01-Feb-2012 | AN-No. 1MA193
This application note describes three ways of generating multicarrier signals with high dynamic range for testing power amplifiers of 3GPP radio base stations. The corresponding sets of waveform (*.wv) files are delivered with this application note. The WinIQSIM™ software is used to download these files to the signal generator(s).Tips for optimizing spectrum analyzer settings in order to measure the Adjacent Channel Leakage Ratio (ACLR) are given.
17-Feb-2005 | AN-No. 1MA48
Adjacent Channel Power performance of power amplifiers used in digital TV systems has to be guaranteed over a wide frequency range, 54 to 890 MHz, which may lead to time consuming test procedures. The application software described here provides swept ACP analysis, using AMIQ and SMIQ for signal generation and FSP, FSU or FSE for signal analysis. ACP measurement is performed according to FCC Regulation 47CFR 73.622(h).
16-Oct-2001 | AN-No. 1MA43
Noise Power Ratio Signal Generation and Measurement
Noise Power Ratio (NPR) is an add-on tool for WinIQSIM™ to generate noise power ratio stimulus signals and measure the resulting noise power ratio of a device under test (DUT) using Rohde & Schwarz instruments via LAN or GPIB bus.
06-Nov-2015 | AN-No. 1MA29
This application note provides information about measurements on pulsed signals with a spectrum analyzer. Examples show the practical realisation of measurements like pulse width, peak power and mean power, and the limitations of spectrum analyzer measurements. A method for long time average power measurement is explained.
16-Jan-2003 | AN-No. 1EF48
In addition to frequency, power and long-term stability, short-term stability or its equivalent, phase noise, is an important characteristic of signal sources. For example, the phase noise of conversion oscillators of receivers obtained in the presence of a strong signal determines adjacent-channel sensitivity. In the case of transmitters, the phase noise of the oscillator together with the modulator characteristics is responsible for the power generated in adjacent channels. The phase noise of oscillators or synthesizers and the relevant measurements therefore play an important role in radio transmission systems.
16-Jan-2002 | AN-No. 1EF16
This application note describes how noise figure and gain of amplifiers or converters in the microwave range from 50 GHz to 67 GHz are measured. For this purpose the R&S FSU67 spectrum analyzer is equipped with application firmware R&S FS-K30 in combination with the Noisecom NC5115-60G, or NC5115-60GT Noise Figure Test Set.
12-May-2009 | AN-No. 1EF64
Measuring the spurious emissions of transmitters used in GSM, DCS 1800 and PCS 1900 networks requires highly complex test setups since con-ventional spectrum analyzers do not have the necessary dynamic range. To obtain this range, notch filters are used to suppress the useful sig-nal. The spectrum analyzers of the FSE family make it possible for the first time to verify com-pliance with stipulated limit values for spurious emissions within the transmission band and out-side the reception band without the use of notch filters. The measurement problem and its solution by means of FSE are described in the following by way of the example of a GSM base station.
16-Jan-2002 | AN-No. 1EF17
With AMPTUNE amplifier nonlinearity can be measured with signals that are typical for the signals encountered by the amplifier in day-to-day use. The measurement can be checked by pre-distorting the control signal. Also, the results can be automatically stored for further processing with external programs.
26-Oct-2005 | AN-No. 1MA27
This application note provides a summary of the current test solutions available with Rohde & Schwarz equipment. The opportunities provided by the individual devices are presented briefly and a demonstration using a spectrum analyzer and a vector signal generator is described.
14-Sep-2009 | AN-No. 1MA112
The Electromagnetic Disturbance (EMD) emitted by Proximity-Integrated-Circuit-Cards (PICC) is a unwanted form of load modulation. This Application Note describes a method for measuring EMD during data transmission using vector signal analysis
19-Oct-2007 | AN-No. 1MA120
Short measurement time in conjunction with high accuracy and repeatability of results are essential for efficient testing of mobile phone power amplifiers. Power Meter R&S®NRP, Signal Generator R&S®SMIQ, Spectrum Analyzers R&S®FSP/FSU/FSQ and Power Supply R&S®NGMO2 offer optimum characteristics such as high accuracy, fast settling speed and short measurement time in programmed mode. This application note concentrates on testing GSM/EDGE mobile power amplifiers and shows typical test setups and programming examples for Signal Generator R&S®SMIQ and Spectrum Analyzer R&S®FSP/FSU/FSQ, benchmark numbers and repeatability results.
29-Apr-2004 | AN-No. 1MA66
This Application Note introduces HSDPA technology and test and measurement requirements according to 3GPP release 5 specifications. Important HSDPA measurements and example applications are illustrated by means of Rohde & Schwarz products.
01-Feb-2005 | AN-No. 1MA82
This Application Note describes how to perform measurements on power amplifiers for TD-SCDMA base stations to specification TS 25.142 using Rohde & Schwarz generators, power meters and signal/spectrum analyzers. The TD-SCDMA application firmware for Rohde & Schwarz generators and analyzers as well as their outstanding performance facilitate efficient and rapid measurements.
31-Jul-2007 | AN-No. 1MA103
High Speed Uplink Packet Access (HSUPA) is a 3GPP release 6 feature for WCDMA. Objective is to achieve uplink data rates of up to 5.76 Mbps and increase throughput and capacity. This application note introduces HSUPA concepts and explains key features.
09-Feb-2006 | AN-No. 1MA94
Application Note 1MA104 shows you how to quickly and easily create TD-SCDMA test signals for user equipment and base station tests as stipulated in the standards TS 34.122 and TS 25.142.
10-May-2007 | AN-No. 1MA104
The constantly decreasing size of components and the available board space form a challenge to place adequate test connections for RF instruments. Recent improvements in the availability and use of high performance differential building blocks in RF circuits intensify the problems of connecting test equipment. Using oscilloscope probes is a possibility to perform measurements by connecting to printed circuit board lines and chip contacts where only a minimal area is required to make contact. This application note provides information on how to use oscilloscope probes in RF measurements using spectrum analyzers, and show the results of differential measurements with a spectrum analyzer.
28-Jun-2013 | AN-No. 1EF84
This Application Note describes measurements compliant with the CDMA2000® base station standard described in 3GPP2 C.S0010-C v2.0 / TIA/EIA-97-F-1. The primary focus is on solutions for generating and analyzing CDMA2000® signals. The special characteristics that make the selected signal generators and signal analyzers highly suitable for this purpose are detailed, and remote control programming is demonstrated by means of a free-of-charge program.
15-Sep-2009 | AN-No. 1MA109
This application note provides hints for implementing remote control programs using Rohde & Schwarz spectrum and network analyzers. The document makes suggestions for improved remote control performance and describes aspects of measurement synchronization in detail. Finally the document discusses some typical challenges of remote control in production test.
19-Aug-2014 | AN-No. 1EF62
Application Note 1MA68 has been replaced by .
10-Dec-2008 | AN-No. 1MA68
The R&S spectrum analyzers and signal analyzers offer an additional equalizer filter in the Vector Signal Analysis Application Firmware R&S FSQ-K70/FSx-B73, which is a powerful tool for measurement and analysis of vector-modulated signals. This application note describes the functionality of the equalizer filter and how to set the filter parameter manually in an accurate and fast way.
06-Feb-2009 | AN-No. 1EF61
FSxRecordPlay is a program for recording the trace data in frequency and time domain from Rohde & Schwarz spectrum analyzers and measurement receivers via IEEE bus, LAN/Internet or internal remote control connection. The stream waveform data can be played back and analyzed directly in this software with variable speed.
20-May-2010 | AN-No. RAC-0605-0004