This application note explains the concept of Adjacent Channel Leakage Ratio (ACLR) measurement on 3GPP W-CDMA signals with the spectrum analyzer FSP. Optimum operation for both the integrated bandwidth method and the new time domain method are shown via explanation of the signal behavior and the internal structure of the FSP. With the time domain method the spectrum analyzer family FSP provides a new approach featuring a very short measurement time compared to the integrated bandwidth method.
12-Jan-2001 | AN-No. 1EF41
In digital wireless communication systems one or multiple users are assigned to a physical RF channel. With analog systems only one user per carrier is possible. Output spectrum of the transmitter has to be restricted to the assigned channel in order to avoid interference with the neighbor channels. With the switch over to digital modulation formats more user per channel are possible. They share one channel by using only part of the time for transmission (Time Division Multiplex Access, TDMA) or by coding the transmission by orthogonal sequences for distinction to other users (Code Division Multiples Access, CDMA). Beneath the restriction of modulation spectrum with TDMA systems also time behavior of the transmitted signal is critical. One reason is that in a multi-user situation only one user is allowed to transmit within his assigned time slots. Another reason is that by switching a carrier on and off spectrum of the transmitter splatters and causes additional interference in other RF channels.
17-Jan-2002 | AN-No. 1EF32
RF pulse measurements, to characterize the signal in the frequency domain, are traditionally carried out on an RF spectrum analyzer. For time related pulse parameters, oscilloscopes are widely used. However, the measurement capabilities of state of the art test and measurement equipment has evolved over time and crosses domains. With a combination of R&S®RTO digital oscilloscope and dedicated pulse analysis software R&S®VSE-K6, pulse signals can be analyzed in both domains, frequency and time.The R&S®RTO digital oscilloscopes are unique in that they allow output of I/Q data for processing. This application note focusses on signal measurement using this instrument.Analysis of an L-/S-band ATC RADAR utilizing the R&S®RTO2044 oscilloscope running Vector Signal Explorer Software R&S®VSE and Pulse Analysis personality R&S®VSE-K6 is followed by measurements on an X-band RADAR utilizing R&S®FSW, R&S®FPS, R&S®FSV or FSVA signal & spectrum analyzers with the same dedicated R&S®VSE-K6 software.
18-Oct-2016 | AN-No. 1MA249
The test case wizard enables the signal generator to set up all required parameters for conformance testing of 5G NR base stations in no time with just a few clicks.
25-May-2021
Short test times in conjunction with accurate and repeatable measurement results are essential when testing and calibrating mobile phones at board level. The R&S FSP Spectrum Analyzer offers wide dynamic range, stable and accurate results within shortest sweep time, making it the ideal choice for high-volume production testing. The utilisation of both the list mode feature and the marker list function for the Spectrum Analyzer R&S FSP, with its unsurpassed measurement speed via remote control are demonstrated in this application note.
29-Aug-2003 | AN-No. 1MA65
The strict requirement of network synchronization is as old as digital cellular mobile networks. As soon as cells have a neighbor relationship, network synchronization is mandatory in both the frequency and time domains in order to ensure UE QoE and performance (Handover, MIMO, data throughput, etc.). This educational note describes how 5G NR with its extremely flexible specifications is affected by these synchronization requirements, and how it can be measured?
17-Aug-2021 | AN-No. 8NT05
While Mobile phones are allowed to require approximately 3 time slots for switching from transmission to reception, base stations must be able to transmit and receive at a new frequency in every time slot in the frequency hopping mode. This behaviour must of course be tested and measurements carried out on the base station transmitter and receiver. Since there is no signal generator which is able to settle at different frequencies from one to the next time slot with GSM modulation, a solution to this problem was found by linking two Signal Generators SME in such a way that they alternately provide signals at different frequencies.
01-Jul-1999 | AN-No. 1GPAN28
Automated test equipment (ATE) is a cornerstone in production facilities. Devices under test (DUT) have to be measured according to various limits to ensure safe and reliable operation for the user. A production facility must ensure that these tests are performed properly and cover all the necessary test cases. However, the tests must also be executed with sufficient speed. Oscilloscopes (e.g. the MXO series from Rohde & Schwarz) are often a typical part of ATE and can improve the workflow with a dedicated “waiting for trigger” signal.
30-May-2024
This application note explains how to synchronize the signals from multiple R&S®SMBV100A vector signal generators in time.The synchronization of the instruments is based on a master-slave principle where one R&S®SMBV100A acts as master and supplies all necessary synchronization signals to the other instruments (slaves). The setup is simple and provides highly synchronized test signals. Time synchronous signals are needed in several applications. The master-slave setup is ideal for basic MIMO tests, certain GNSS test scenarios and WLAN IEEE 802.11ac non-contiguous channel generation. Furthermore, synchronous baseband signals are the basis for generating phase coherent RF signals with the R&S®SMBV100A.
09-Jul-2013 | AN-No. 1GP84
For automated test applications, measurement time is often as important as the quality of the measurement. As with many situations, time is money. In practice, phase noise measurements are generally not considered fast, but test engineers still desire to save as much test time as possible. The Rohde & Schwarz®FSWP (FSWP) is a modern, digital signal processing based, phase-noise test set that performs many tasks in parallel in an effort to improve measurements speed. However, several measurement settings drastically affect measurement speed. This paper will discuss these settings and provide suggestions on improving overall measurement speed.The three key instrument parameters that affect FSWP measurement speed are:1. Number of cross correlations2. Resolution bandwidth (RBW)3. Offset frequency span
08-Oct-2020 | AN-No. GFM354
Oscilloscopes are the workhorses for power electronics engineers. With powerful and easyto- use FFT analysis capabilities, their application fields extend to EMI debugging – and that saves a lot of time and money. A typical task is verifying the effectiveness of an EMI filter – early in the development phase.
23-Sep-2019
EMI compliance is becoming a major concern for advanced power electronics due to increasing switching speeds. Correlated time-frequency measurements help optimize gate driving and minimize electromagnetic emissions early on during development.
27-Apr-2023
Interferences on audio transmissions, which happens only from time to time, are very difficult to be measured. This application note describes a method, used by the audio analyzers UPL and UPD, to monitor test tones without any interruption and detecting even the shortest clicks.
04-Jun-1998 | AN-No. 1GA31
TeleZüri, Switzerland’s most successful regional TV station, has switched from tape-based operations to file-based workflows. At the same time, TeleZüri was introducing HD as standard resolution in its workflows.
18-Nov-2014
This application note provides information about measurements on pulsed signals with a spectrum analyzer. Examples show the practical realisation of measurements like pulse width, peak power and mean power, and the limitations of spectrum analyzer measurements. A method for long time average power measurement is explained.
16-Jan-2003 | AN-No. 1EF48
In order to allow users to quickly generate different reports, ELEKTRA provides several ways or supporting the user. This application note describes the various methods and their benefits. It is not a how-to step-by-step guide, but shows the principles of operation.
27-Jul-2022 | AN-No. 1SL384
Receiver diversity improves reception quality by using multiple antennas with a preferably low correlation factor between each receive path. The result is a much more robust reception, since a deep fade will not affect all received signals at the same time.However, the complex geometry and positioning constraints for antennas of the receiving devices can introduce an unwanted correlation between channels. The popular diversity test setup consisting of several independent transmitters does not serve the needs of a realistic simulation, because radio channel correlation is not simulated.This application note explains a compact and versatile MIMO test solution for any common broadcast standard with real time fading including the simulation of channel correlation for a 1x4 MIMO system.The test setup allows very precisely specified individual multipath profiles.
11-Oct-2017 | AN-No. 1GP114
With the R&S®Pulse Sequencer radar simulation software, users can easily and intuitively create scenarios for simulation of angle of arrival (AoA). Together with multiple coupled R&S®SMW200A vector signal generators, this solution allows quick and thorough performance characterization of all types of direction finding equipment such as devices that use amplitude comparison, interferometric or time difference of arrival (TDOA) techniques. This document describes our test solution for testing devices that use amplitude comparison techniques.
02-Apr-2020
Simulation can be a big time-saver when designing EMI filters for DC/DC converters. Power supply control chip vendors offer various filter design tools that provide reasonable design choices for filter simulation before any hardware prototype is available. However, simulated results can differ significantly for different tools if simulated models are not accurate or do not cover all the relevant components. Performing a hardware measurement to evaluate the effectiveness of a simulated EMI filter is therefore indispensable.
21-Sep-2021
EMI compliance is becoming a major concern for advanced power electronics due to increasing switching speeds. Correlated time-frequency measurements help optimize gate driving and minimize electromagnetic emissions early on during development.
22-Nov-2018
Power converter and inverter designs for higher power levels are usually based on hard switching half bridge configurations. In such setups, users must pay particular attention to proper switching operations to prevent shoot-through events. Setting up complex real-time trigger conditions using the R&S®RTE and R&S®RTO oscilloscopes increases the test coverage and robustness of converter and inverter systems.
10-Aug-2020
FSxRecordPlay is a program for recording the trace data in frequency and time domain from Rohde & Schwarz spectrum analyzers and measurement receivers via IEEE bus, LAN/Internet or internal remote control connection. The stream waveform data can be played back and analyzed directly in this software with variable speed.
20-May-2010 | AN-No. RAC-0605-0004
Rohde & Schwarz signal generators present a compact easy-to-use solution for generating phase coherent signals. Different generator models can be coupled to optimally fit user requirements in terms of number of phase coherent channels and RF frequency range.This application note explains how to generate phase coherent signals, details what to consider and how to best calibrate the relative phases and timing between the individual channels. This document also presents various measurements of the phase stability over time for different RF frequencies.
07-Sep-2016 | AN-No. 1GP108
This application note describes remote operation or monitoring of the real time spectrum analyzer R&S® FSVR through a standard web browser. The common cross-platform technology Virtual Network Computing (VNC) is used as a server on the instrument.
27-Jul-2010 | AN-No. 1EF74
An offline AC/DC switching converter has no separate bias power supply that provides power to the control integrated circuit itself. Here, an auxiliary primary winding and discrete components are added to supply power to the control circuit. Verifying this circuitry is essential and requires accurate and detailed signal level and timing measurements. The startup sequence takes a long time, which needs to be taken into consideration in the measurement and requires an instrument with sufficient memory.
23-Nov-2022
Analyzing RF pulses is a key aspect of pulsed radar applications, e.g. in air traffic control (ATC), maritime radar or scientific measurements of the ionosphere. Analyzing the envelope and the modulation of the pulse is essential, because they contain important information to characterize the application. The R&S®RTO and R&S®RTP oscilloscopes are capable of triggering precisely on a pulse as a prerequisite for time domain and frequency domain analysis. This document describes the use of the R&S®RTO and R&S®RTP to trigger exactly on pulses in preparation for further in-depth measurements such as RF pulse measurements on an ATC signal.
13-Mar-2019
This application note describes how to remotely control the R&S SGMA RF sources SGT100A and SGS100A with a special focus on their high-speed remote control capabilities via LAN based FAST Socket or FAST PCI Express (PCIe) connections which allow round trip setting times of only 100μs.It therefore provides a brief introduction into the general remote control capabilities, explains the interaction of the different SW protocol layers and drivers, and in detail describes how to establish a high-speed remote control connection. Finally, a comparison of the measured setting time performance of the different remote control approaches is provided.
12-May-2016 | AN-No. 1GP107
TDMA communications systems like GSM, DCS 1800 or PCS 1900 make effective use of the frequency spectrum by assigning several subscribers to the same frequency channel. Each subscriber has access to one predefined time slot for transmitting information. With GSM eight subscribers share one frequency channel with a bandwidth of 200 kHz. In order not to disturb the other users of the 200-kHz channel it has to be ensured that, for instance, a mobile sends in the assigned time slot only and that no power is emitted by the transmitter at other times. For this reason the transmitter power is practically switched off in the transmission intervals.
16-Jan-2002 | AN-No. 1EF18
The present R&S®SMW-K503/-K504 Interface Control Document contains information on- the R&S descriptor word format, including pulse descriptor words and timed control descriptor words in basic and expert mode- Timing requirements and limitations of the real-time control interface- Properties of the ADV DATA/CTRL network interfaceIt is intended for use by customers using descriptor words to control the R&S®SMW200A in real-time. The interface control document specifies the interface between the customers hardware used for provision of descriptor words and the R&S®SMW200A ADV DATA/CTRL interface. Additional information on descriptor word processing inside the R&S®SMW200A is provided.