This application note shows all necessary settings for measuring shielding effectiveness using the R&S®EMC32-K48 option via R&S®EMC32 Measurement Software.
01-Dec-2015 | AN-No. 1SP19
This application note describes how to use the mask and limit test features of the R&S®RTO, R&S®RTE and R&S®RTM Digital Oscilloscopes for EUT monitoring of signal forms, jitter etc. with the R&S®EMC32 Measurement Software. The mask test function allows autonomous characterization of digital signal integrity during EMS tests. R&S®EMC32 software records violations of userdefined limits or mask templates and evaluates the immunity threshold at frequencies of critical electromagnetic susceptibility.
20-Apr-2015 | AN-No. 1MA242
This application note shows all necessary settings for performing Dual Receiver Measurement using the R&S®EMC32-K27 option via R&S® EMC32 Measurement Software.
28-Sep-2017 | AN-No. 1SP20
This application note shows how to configure the R&S®AdVISE visual inspection software to automate the immunity testing in line with EN 55020 and CISPR 35 on TV sets and monitors.
30-Jul-2020 | AN-No. 1S007
The option R&S®EMC32-K84 extends the internal report generator to support the generation of a summary test report over all selected test cases done for a DUT. Additional the report is directly written to Microsoft®Word and thus can be easily combined with customer specific report templates.This Application Note shows all necessary steps on an example report to configure and execute the report generation.
23-Apr-2015 | AN-No. 1SP09
The ‘Data Reduction’ sequence step is an essential part of an EMI Auto Test since it evaluates the relevant frequencies at which the final measurements are to be done. The intention of this application note is to make the data reduction data flow more transparent (contents of input and output tables) and how the parameters (location and relations) influence the evaluation algorithm.
16-Nov-2011 | AN-No. 1SP02
This application note explains step by step all necessary settings for transmitting parameters of the disturbance signal from an EMS test to a dAV Camera System via serial port or LAN interface. The dAV Camera System overlays these parameters onto the camera signal.
10-Dec-2019
This application note shows how to configure, calibrate and perform conducted EMS (Electro Magnetic Susceptibility) measurements according to IEC / EN 61000-4-6 and EMI (Electro Magnetic Interference) measurements according to CISPR 16-2-1 with the R&S®EMC32 software tool.
19-Jul-2013 | AN-No. 1MA212
Using R&S®ELEKTRA Migration Tool
The R&S®ELEKTRA EMC test software is the successor of the R&S®EMC32 EMC measurement software. Like the R&S®EMC32 EMC measurement software, the R&S®ELEKTRA offers a solution that controls complete EMC systems and automates measurements on equipment under test (EUT) that is being tested for emissions (EMI) and immunity (EMS) compliance. It has more features and test types compared to R&S®EMC32.As both software platforms use different file formats, R&S®EMC32 users who upgrade their existing software to the R&S®ELEKTRA platform need to perform a file conversion before migrating their data to the R&S®ELEKTRA platform. This is done by using the R&S®ELEKTRA Migration Tool, which is installed automatically with each R&S®ELEKTRA installation.This Application Note describes how to use the R&S®ELEKTRA Migration Tool (version 4.4 onwards) for converting the backup data into the XML format that can be interpreted by the R&S®ELEKTRA software. It also provides recommended conversion steps (Chapter 5) and troubleshooting tips (Chapter 6). For instructions on migrating the data using R&S®ELEKTRA Migration Tool below version 4.4, refer to the R&S®ELEKTRA user manual. For better user experience, we recommend using the latest software version for migration.This Application Note does not describe the steps to backup data using the R&S®EMC32 or R&S®ES-SCAN software. For procedures on how to do so, refer to their respective manuals.
04-May-2023 | AN-No. 1SL396
This application note describes how to use the generic interface in R&S®AdVISE for remote operation.
19-Jun-2020 | AN-No. 1S002
This application note describes how to detect even small fails in dynamic turn indicators with R&S®AdVISE.
30-Jul-2020 | AN-No. 1S006
EMI Automotive Band Evaluation extension is an on-board EMI measurement sequence in broadband and communications frequency bands for automotive and aerospace applications. This application notes shows how to configure, run, and automatically document tests in a sequence coming with EMC32-K51.
17-Jul-2014 | AN-No. 1SP07
The option R&S®EMC32-K24 extends the emission measurement of the EMI Auto Test (R&S®EMC32-K10) with interactive measurement capabilities. This extension is useful for test verification and measurement during product improvement.
25-Jun-2014 | AN-No. 1SP06
R&S®AdVISE is a visual inspection software to monitor different regions of interest (ROIs) in a video for visible and audible changes. It automates the process of visually monitoring equipment under test during a test sequence and therefore eliminates human inattention, ensures reproducible results and simplifies the test documentation. R&S®AdVISE offers the possibility to monitor up to 32 ROIs in one video with 12 different specialized ROI types for different kinds of events. That allows the user to apply R&S®AdVISE to all sorts of individual test setups.This application note explains how to setup R&S®AdVISE to monitor the temperature of an EUT by using an infrared camera.
14-Sep-2020 | AN-No. 1S008
The option R&S®EMC32-K23 extends the emission measurement of the EMI Auto Test (R&S®EMC32-K10) with 3D measurement capabilities.This extension is useful to display the 3D radiation pattern of each frequency.This Application Notes shows all necessary settings for 3D measurement.
26-Aug-2014 | AN-No. 1SP08