Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
3166 Results
Next Generation eCall uses LTE and IMS for an emergency call. The R&S®CMW500 radio communication tester emulates an LTE network with integrated IMS server. Equipped with the R&S®CMW-KA096 test software enables to test NG eCall-capable in-vehicle systems.
This application note explains battery life tests using RT-ZVC in combination with CMWrun and CMW500, including example applications.
17-Feb-2017 | AN-No. 1MA281
Simulation of DVB-T Channel for Antenna Diversity Reception
31-Jul-2003 | AN-No. 7BM06
RF Level Measurement Uncertainties with the Measuring Receiver R&S FSMR
28-Mar-2006 | AN-No. 1MA92
This application note describes how all required performance tests can be performed quickly and easily by using vector signal generators.
11-May-2016 | AN-No. 1MA162
XM satellite is a terrestrial, repeater-assisted satellite digital audio radio service (SDARS) in the United States for nationwide mobile car reception.
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
22-Oct-2019 | Press Release | Cybersecurity
R&S®Cloud Protector by Rohde & Schwarz Cybersecurity receives international Security AwardComputing Security Awards 2019: R&S®Cloud Protector security solution wins category "New Cloud Delivered Solution of the Year".
19-Feb-2020 | Press Release | Wireless communications
Rohde & Schwarz and Decawave cooperate to develop T&M capabilities for Ultra Wideband technologiesRohde & Schwarz and Decawave demonstrate test functions for the new generation of Decawave UWB devices with the new generation of Rohde & Schwarz radio communication tester, the R&S CMP200. With this solution, both companies address manufacturers planning wireless devices using Ultra Wideband (UWB) technology to provide secure location-based services.
The R&S ® FSWP phase noise analyzer is a highend instrument designed to accurately analyze noise performance of key components in radar and communications systems.
27-Oct-2017
By making the simulation of fading scenarios easy and flexible, the R&S®SMW200A is the perfect tool to verify that your MIMO receiver can meet performance requirements.
27-Oct-2020
Rohde & Schwarz Manual for SMA adaptor R&S®RT-ZF7A.
How to setup the Hameg HMP2000 and 4000 Series for TCP/IP RAW socket connection using NI VISA
When using the HMF 25xx the output impedance can be changed. Is it really switched electronically or is it solved by the mathematic way?
Rohde & Schwarz Manual for SMA adaptor R&S®RT-ZF7P.
Information provided by Rohde & Schwarz for R&S®EPL1000 EMI test receiver used in a secured environment
Average Pulse Measurements with VNA In this video we introduce the concept behind making pulse measurements using the average (or narrow band) pulse technique and it’s limitations with respect to the duty cycle. In this video we introduce the concept behind making pulse measurements using the average (or narrow band) pulse technique and it’s limitations with respect to the duty cycle.
09-Nov-2020 | Press Release | Test & measurement
New Rohde & Schwarz System Amplifier Targets Microwave Device ManufacturersAs the market for mobile radio, IoT, satellite and radar applications grows, Rohde & Schwarz has introduced a new approach to the system amplifier challenge. With unprecedented output power, bandwidth and market-leading noise performance, the compact R&S®SAM100 offers users a unique proposition.
04-Oct-2023 | Press Release | Broadcast and Media
5G Broadcast demonstrates emergency warning capabilities for public safety in EstoniaLevira and Rohde & Schwarz have demonstrated 5G Broadcast capabilities for public safety during the crisis training exercise CREVEX 2023 in Estonia.
Rohde & Schwarz instrument security manual for the R&S®ZNH be used in a secured environment.
I am using the command “CONT:AUX:C x” to see when a channel is active. But the respective pin at the AUX connector does not switch to “high”.
Define up to eight zones of any shape and logically combine them over multiple channels or by using math functions. Zone trigger, time and frequency domain, RTO2000 The R&S®RTO oscilloscopes’ zone trigger lets you graphically separate events. Define up to eight zones of any shape and logically combine them over multiple channels or by using math functions.
Nonlinear applications using Rohde & Schwarz vector network analyzers - Product Flyer
Measurement of the phase difference between the MIMO layers is a challenging task in the design of 5G base stations. However, this measurement and its analysis can be easily accomplished using the R&S®NRQ6 frequency selective power sensor and R&S®VSE signal explorer software.
14-Jan-2022
This application note describes the functionality of the equalizer filter and how to set the filter parameter manually in an accurate and fast way.
06-Feb-2009 | AN-No. 1EF61
This application note discusses WLAN standard IEEE 802.11n. It first describes the most important amendments to previous releases and the ambitious new measurement tasks.
26-Apr-2013 | AN-No. 1MA179
This document is divided in two parts and starts with an introduction in AC-DC conversion principles in general. It will present the most common circuits used for different power levels. The switching mode power supply (SMPS) converter will be the main focus as they are used everywhere in the electronics. Especially the flyback converter design in different flavors are highlighted. Nevertheless, all measurements are also applicable for other SMPS converter designs operating at higher power levels.In the second part of this document, most relevant testing methods and procedures of an AC-DC converter are highlighted. For each testing section, a fundamental part will be upfront discussed and it is followed by a presentation of a suitable measurement method. In this second part, the device under test (DUT) is considered as black box device and thus the structure is similar. Therefore, the testing parts consists of methods related to input tests, output tests and a combination of both like efficiency. Of course, some test performed at the output of the converter are also relevant for DC-DC converter, e.g. the validation of the output ripple.
14-Nov-2022 | AN-No. 1SL387
Application Note Peak and Mean Power measurements on wideband FMCW radar signals
28-Jun-2019 | AN-No. 1EF107
This application note provides practical hints to accurately characterize and de-embed these lead-in and lead-out structures with R&S Vector Network Analyzers ZNA, ZNB, ZNBT and ZND.
19-Sep-2022 | AN-No. 1SL367
Arnd Sibila shares his expertise on all radio-related technology topics from 2G to 5G to the latest applications, for example, video streaming