Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1109 Results
Taking the R&S ESR EMI test receiver as an example, this paper looks at a CISPR 16-1-1- compliant test instrument with time domain scanning capabilities. The paper compares the measurement speed and level measurement accuracy of a conventional stepped frequency scan versus an advanced FFT-based time domain scan. It also contains guidance on making optimum use of time domain scans.
29-Jan-2014 | AN-No. 1EE24
The Federal Communications Commission (FCC) ruled that no later than February 17, 2009, all analog NTSC broadcasting must come to an end. It is therefore not surprising that the demand for ATSC receivers is high at the time this application note was published. ATSC TV sets and set-tops are subject to the ATSC recommended practice Doc.A/74 “Receiver Performance Guidelines” before they can be sold freely in the markets that adopted the standard. Although the number of tests defined in Doc.A/74 is less extensive then the ones for their DVB-T counterparts (EN62002, MBRAI), some clarification is nevertheless due.
27-Sep-2012 | AN-No. 7BM71
This application note provides an introduction to the DDR memory technology and explains common challenges, related to the specific nature of DDR data, command / address and control buses and describes the typical measurements to verify and debug DDR system designs.The paper explains the recommended test points and the connection of oscilloscope probes as well as the compensation of effects from DDR interposers via deembedding. The document describes efficient Signal Integrity verification with eye diagram measurements, advanced triggering and TDR/TDT functionality. Given the high number of signal lines and the dynamic bus termination, SSN (simultaneous switching noise) has a significant effect in DDR memory designs and Signal Integrity as well as Power Integrity is highly pattern dependent. We introduce techniques to achieve high acquisition rates and help to efficiently detect worst case scenarios, affecting the performance of the overall memory design. The document also includes a close look on Power Integrity.Providing best practice examples in the design verification and debugging process, the document addresses all system designers and test engineers, working on DDR memory designs.
30-Oct-2020 | AN-No. GFM340
This application note describes ATSC Mobile DTV standard A/153, ATSC-M/H. This standard is completely implemented in the R&S®AEM100 ATSC-M/H Emission Multiplexer.
22-Jan-2011 | AN-No. 7EB01
Volker Fischer 1EF86 LTE, MIMO, LTE-MIMO, RTO1044, SMU200A, K102, K103, K102PC, K103PC Testing LTE MIMO Signals using a R&S RTO Oscilloscope Testing LTE MIMO Signals using a R&S®RTO Oscilloscope Volker Fischer 1EF86 LTE, MIMO, LTE-MIMO, RTO1044, SMU200A, K102, K103, K102PC, K103PC Testing LTE MIMO Signals using a R&S RTO Oscilloscope Related products
24-Apr-2013 | AN-No. 1EF86
Most of the tests specified in standard TS 34.121 [1] for 3GPP Rel-6 can be performed with R&S®CMU200. This document provides a step by step guide on how to perform Rel-6 measurements on transmitter characteristics and performance tests according to TS 34.121 V8.7.0 clauses 5 and 10 with stand-alone R&S®CMU200. Test cases that require additional instruments, e.g. fading generator (R&S®SMU200A or R&S®AMU200A) will be discussed in brief in this application note with recommended reference. A set of *.sav files based on R&S®CMU200 firmware V5.03 for UE supporting operating band I and power class 3 in RMC 12.2 kbps + HSPA is attached to this application note.
07-Oct-2009 | AN-No. 1CM73
The R&S®NRP-Z power sensors from Rohde & Schwarz represent the latest in power measurement technology. They offer all the functionality of conventional power meters, and more, within the small housing of a power sensor. This application note serves as a coding guide for situations in which the R&S®NRP-Z power sensors are to be used in custom test and measurement software.
06-Mar-2012 | AN-No. 1GP69
This application note describes how to create and generate standard-conform IEEE 802.15.4 test signals with the Rohde & Schwarz Vector Signal Generators (VSG).
08-Jan-2016 | AN-No. 1GP105
Combining the R&S®Pulse Sequencer software with one of the vector signal generators from Rohde & Schwarz is the perfect solution for defining and playing pulses.
09-May-2017
Validating switching converter stability is vital for any power supply design. Frequency loop and load transient responses are often used to ensure switching converter stability. Even as frequency loop response becomes more important to design validation, load transient response is still commonly used. Load transient response can also be enhanced by visualizing the positive duty cycle for pulse width modulation (PWM) signals over time. A modern oscilloscope can do this, while also helping identify unknown converter effects.
09-May-2023
With options ZVR-B4 (mixer measurements), ZVR-B5 (nonlinear measurements) and ZVR-B7 (power calibration) installed, signal generators and power meters can be controlled from ZVR network analyzers via the IEC/IEEE bus. Customary signal generators and power meters are supported by the device firmware. This application note describes how user-specific configuration files can be generated for and adjusted to external equipment of these two categories.
19-Oct-1998 | AN-No. 1EZ46
This application note shows how to operate the Automation Manager tool in the R&S® CRTU-W to perform an automated FTP operation during a test scenario.
22-Nov-2007 | AN-No. 1CM68
Spectrum Rider, FPH, FSH, ZPH, Cable Rider, ZVH, 5G, Interference hunting, Zero span mode, G NR TDD signal Handheld solutions from Rohde & Schwarz support a gated trigger, enabling users to separate uplink and downlink signals in the time domain. 5G NR – interference hunting in the uplink of TDD networks Spectrum Rider, FPH, FSH, ZPH, Cable Rider, ZVH, 5G, Interference hunting, Zero span mode, G NR
09-Apr-2019
VSC4G, VCS-G4, VSC R&S VCS-4G for simulator and training systems. CERTIUM VCS for simulator and training systems VSC4G, VCS-G4, VSC R&S VCS-4G for simulator and training systems. CERTIUM VCS for simulator and training systems VSC4G, VCS-G4, VSC R&S VCS-4G for simulator and training systems. Related products
18-Jun-2013
This application note describes measurements compliant with the cdma2000® standard described in TIA/EIA-97-C and TIA/EIA-98-C. The primary focus is on solutions for generating and analyzing cdma2000® signals with equipment from Rohde & Schwarz. The special characteristics that make the signal generators and signal analyzers eminently suitable for this purpose are detailed.
27-Mar-2001 | AN-No. 1MA34
The Rohde & Schwarz SFU supports several modes of level setting. This Application Note describes the differences between these modes and especially describes a method to achieve a seamless transition without any impact to the output signal during a change of settings on an Rohde & Schwarz SFU (Firmware version > 1.30).
23-Jun-2006 | AN-No. 7BM54
Signal generators are often used in automated test environment applications. The replacement of those instruments, e.g., due to malfunction or standard replacement procedures requires special care to be taken in consideration. Replacement of those instruments requires compabitiblity between the replacement and the replaced device in at least the electrical and remote-control features. This application note describes in detail how to use the emulation modes of the R&S® series SMA100A, SMB100A, SMF100A signal generators.
24-Jun-2008 | AN-No. 1GP71
A test setup is described for easy demonstration of the Bit Error Rate Test (BERT) function of AMIQ/AMIQ-B1. The test setup contains I/Q Modulation Generator AMIQ/AMIQ-B1 controlled by I/Q Simulation Software WinIQSIM, Vector Signal Generator SMIQ and Spectrum/Vector Signal Analyzer FSE/FSE-B7. The FSE with FSE-B7 is used as online FSK demodulator (setting: Analog demodulation, FM Signal, DC coupling, Real Time On) to demodulate the SMIQ RF signal FSK-modulated by PRBS data. The AMIQ is controlled by WinIQSIM software and receives the demodulated AF output signal from the FSE for BER testing.
29-Sep-1998 | AN-No. 1MA16
LTE user equipment (UE) receiver performance has significant impact to cellular radio network coverage and capacity. It determines the maximum data throughput across the air interface between the LTE base station (eNB, evolved node B) and the mobile network subscriber UE, thus it determines the total capacity across the air interface. Therefore, it is one of the most important measurements to verify the actual receiver performance of individual devices, and a key metric to compare different devices, in particular.This paper shall give an introduction to receiver performance measurements and discusses the measurement metrics as well as the challenges of over the air (OTA) measurements.
31-Aug-2017 | AN-No. 1ST001
Power converters with a full-bridge topology are frequently used in telecommunications and servers that need to be compact, efficient and cost sensitive, making them more complex. Switching patterns for all the main primary switches including synchronous rectifier switches need to be validated after the first protype is built. This complex validation requires proper measurement of switching patterns to prevent catastrophic switching patterns. Expertise and the right measurement tools are essential when identifying unexpected events in the converter switching process.
17-Jan-2024
A whole series of measurements has to be carried out for drafting an acceptance test report for a VHF sound broadcasting transmitter in compliance with ARD Specifications 5/3.1 (= TL 5820-3018 of the Deutsche Bundespost). As in most cases parameters like transmitter output power, frequency stability, spurious modulation, etc. have to be measured in the two stereo channels of the transmitter separately and at different modulation frequencies and frequency deviation, manual-controlled measurements are very time-consuming. In addition, a great variety of test equipment eg AF generator, stereodecoder, level meter, etc. is required for the measurements. FMAB with option FMA-B4 (AM/FM Calibrator / AF Generator) is ideally suitable for these measurements on VHF sound broadcasting receivers. The internal AF generator provides the signals required for the left and the right stereo channel. The MPX signal from the VHF transmitter is decoded by the built-in stereodecoder. As a result many of the tests and measurements required for the acceptance of VHF sound broadcasting receivers can be carried out without any additional test equipment being required. To give an example, a test program running under the graphics user interface Microsoft Windows has been developed for carrying out automatic power and modulation measurements via a PC.
04-Jun-1998 | AN-No. 1EF09
Power amplifiers for WCDMA/3GPP base stations should have the best possible spectral purity and smallest intermodulation distortion, in order to prevent disturbance of the neighbouring channels. To test such amplifiers, signal generators are required that can generate WCDMA signals with low noise and intermodulation over a very wide dynamic range. The R&S SMIQ03HD signal generator with its outstanding Adjacent Channel Leakage Ratio (ACLR) performance is especially designed for these applications. This application note describes how to use SMIQ03HD to get the best performance with 3GPP single and multi carrier signals.
02-Sep-2002 | AN-No. 1GP52
GTSL (Generic Test Software Library ) is part of the production test systems R&S TS7100/ TS7180, simplifies very much test programming with the CMU200 and can be used together with the ”Test Executive” TestStand ® from National Instruments. This application note shows how GTSL can be implemented outside a TestStand ® environment and describes the accompanying source code of a demo ”Test Executive” developed in Microsoft ® Visual C++.
02-Jul-2002 | AN-No. 1SC01
R&S®Series4200 detection of simultaneous transmissions (DSiT) option for air traffic control
21-Aug-2014
The compact R&S®CMA180 Radio Test Set allows straighforward tests on devices that use analog or digital modulation and demodulation formats. This application note focusses on the use of the digital radio capabilities for measurements on radio transceiving devices in terms of their functionality and parameter characterization. Also shown is how to use the instrument with the various software tools available from Rohde & Schwarz for creating and evaluating digitally modulated signals. Various software examples are provided as free download along this paper. This application note addresses readers who develop, produce or optimize digital radio transmitting and receiving devices or maintain analog radio communication equipment alongside those with digital modulation.
10-Feb-2017 | AN-No. 1MA277
This application note describes how the most important fading tests for mobile phonesin all GSM frequency bands can be carried out cost-effectively using a combination of a CRTP/C02 Radiocommunication Tester and SMIQ Signal Generator.
23-May-2000 | AN-No. 1MA19
This application note describes how to generate test signals with Rohde & Schwarz signal generators of the R&S® SMx family (R&S®SMA100A, R&S®SMF100A, R&S®SML, R&S®SMT, and R&S®SMIQ) to perform interference testing on implantable medical devices using a small application software.
15-Jul-2009 | AN-No. RCS0812-0065
This Application Note describes characterization of devices used in radar systems with pulsed signals. The emphasis is on measurements using vector network analyzers (VNAs), signal generators, vector signal generators and spectrum analyzers.
18-Jan-2008 | AN-No. 1MA124
This Application Note describes the HSDPA uplink channel structure. Challenges for UE power amplifier design are outlined, and guidelines how to use R&S measurement equipment for testing UE power amplifiers are provided. An outlook on High Speed Uplink Packet Access (HSUPA) and the impact of HSUPA on the uplink channel structure is given.
11-Jul-2011 | AN-No. 1MA84