R&S®CMPHEAD50 Remote radio head 50 GHz

The next generation broadband remote radio heads

R&S®CMPHEAD50 Remote radio head 50 GHz
Open Lightbox
R&S®CMPHEAD50 Remote radio head 50 GHz
Open Lightbox
R&S®CMPHEAD50 Remote radio head 50 GHz
Open Lightbox
R&S®CMPHEAD50 Remote radio head 50 GHz
Open Lightbox
R&S®CMPHEAD50 Remote radio head 50 GHz
Open Lightbox
R&S®CMPHEAD50 Remote radio head 50 GHz
Open Lightbox
R&S®CMPHEAD50 Remote radio head 50 GHz
Open Lightbox
R&S®CMPHEAD50 Remote radio head 50 GHz
Open Lightbox
R&S®CMPHEAD50 Remote radio head 50 GHz
Open Lightbox
R&S®CMPHEAD50 Remote radio head 50 GHz, Hero view R&S®CMPHEAD50 Remote radio head 50 GHz, Side view R&S®CMPHEAD50 Remote radio head 50 GHz, Front Low R&S®CMPHEAD50 Remote radio head 50 GHz, Back low R&S®CMPHEAD50 Remote radio head 50 GHz, Back high R&S®CMPHEAD50 Remote radio head 50 GHz, Side view R&S®CMPHEAD50 Remote radio head 50 GHz, Side view R&S®CMPHEAD50 Remote radio head 50 GHz, Side view R&S®CMPHEAD50 Remote radio head 50 GHz, Front High

Key facts

  • Full frequency range from 21.84 GHz to 50.2 GHz
  • Wide dynamic range with extra sensitive RX port
  • Dual LO for best RF quality in TX and RX
  • External local oscillator input ports to boost EVM
  • Integrated mmWave RF switch matrix

High performance mmWave converter for non-signaling applications

More dynamic range, full frequency coverage and excellent EVM performance

The R&S®CMPHEAD50 is the only remote radio head supporting bi-directional testing at five mmWave frequency bands with one hardware set and EVM booster ports. It extends the R&S®CMP200 radio communication tester to frequency range 2 (FR2/ FR2-1). The improved performance ensures optimum accuracy for testing next generation FR2 RF designs – from early development to final certification and regulatory compliance. Test with confidence and ensured RF performance with the latest state-of-the-art measurement solution from Rohde&Schwarz.

Features & benefits

Full frequency range from 21.84 GHz to 50.2 GHz

Leading multi-band capabilities

The R&S®CMPHEAD50 is the only RRH that supports all 3GPP frequency bands in FR2-1 in combination with individual external local oscillator (LO) inputs for both RX and TX.

All FR2 frequency bands are covered
Open Lightbox

All FR2 frequency bands are covered

Wide dynamic range with low-noise RX port

Optimized for low power levels

The standard TX and RX ports already have impressive EVM performance over a wide range of power levels, but the new low-noise RX port improves sensitivity to a whole new level.

High dynamic range (HDR) for FR2 testing
Open Lightbox

High dynamic range (HDR) for FR2 testing

Dual LO and external LO ports

For best RF performance in TX and RX direction

Both downlink and uplink paths use separate local oscillators to ensure the best RF signal quality in the TX and RX directions. The R&S®CMPHEAD50 is the only RRH for full UE testing that supports all 3GPP frequency bands in FR2-1 in combination with individual external local oscillator (LO) inputs for both RX and TX. This enables further EVM performance improvements for cutting-edge RF measurements.

EVM booster with external LO ports
Open Lightbox

EVM booster with external LO ports

Specifications
RF characteristics
Frequency range 21.84 GHz to 50.20 GHz
Frequency resolution < 0.1 Hz
RF output power Up to +25 dBm
Output level resolution 0.1 dB
EVM for 5G NR FR2 signal as good as -46 dB / 0.5%

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.