R&S®OSP Open switch and control platform

Modular solution for RF switch and control tasks

R&S®OSP Open switch and control platform
Open Lightbox
R&S®OSP Open switch and control platform
Open Lightbox
R&S®OSP Open switch and control platform
Open Lightbox
R&S®OSP Open switch and control platform
Open Lightbox
R&S®OSP Open switch and control platform
Open Lightbox
R&S®OSP Open switch and control platform
Open Lightbox
R&S®OSP Open switch and control platform
Open Lightbox
R&S®OSP Open switch and control platform, product family, base units R&S®OSP220, front view R&S®OSP230, front view R&S®OSP320, side view R&S®OSP220, back view R&S®OSP320, back view R&S®OSP320 with R&S®OSP-B200S2 satellite and modules

Key facts

  • Modular, reliable and cost-efficient
  • Compact, secure and flexible
  • Powerful control and RF relay modules up to 67 GHz
  • Expandable system configurations
  • Convenient manual and remote control and trigger function

The modular R&S®OSP open switch and control platform is designed for RF switching and controlling.

The R&S®OSP comes in two compact 2 HU models (R&S®OSP220, R&S®OSP230) and one large 3 HU model (R&S®OSP320) to meet diverse test scenario requirements – ranging from desktop configurations for laboratory measurements to complex, rack-integrated test systems. 
The R&S®OSP230 model comes with a manual control touchscreen. The R&S®OSP320 model has a monitor option.

Features & benefits

Modular, reliable, cost-efficient

Essential for reproducible measurements

The modularity of the R&S®OSP family speeds up test and measurement configurations for applications in production, test labs and development. Implementing complex wiring with a single switch and control platform is essential for reliable and reproducible measurements that can be automated for cost-efficient test sequences.

EMC test system with R&S®OSP
Open Lightbox

EMC test system with R&S®OSP

The R&S®OSP distributes generator and amplifier signals to multiplex forward and reverse signals and check interlock signals.

Compact, secure and flexible

Different models in up to 10 flexible module slots

R&S®OSP units are accommodated in a compact 19" cabinet of two or three rack units. 
The powerful CPU and LINUX operating system provide maximum flexibility for controlling switch and control modules, enabling use of  internal and external interfaces. 
The module slots on the rear and front of each unit can be integrated into one, extra-wide triple or double module slot to accept larger modules with an extended range of functions.

Front and rear view of the R&S®OSP220, R&S®OSP230 and R&S®OSP320 switch and control units
Open Lightbox

Front and rear view of the R&S®OSP220, R&S®OSP230 and R&S®OSP320 switch and control units

Detailed overview also available on page 10 of the product brochure.

Powerful control and RF relay modules

Electromechanical relays up to 67 GHz

Options include:

  • Universal electromechanical RF relay modules with N relays (from DC to 12.4 GHz),
  • Electromechanical RF relay modules from DC to 18 GHz, 26.5 GHz, 40 GHz, 50 GHz and 67 GHz
  • Solid-state relay (SSR) modules (up to 43.5 GHz), digital I/O and multiplexer modules
  • Special system modules make implementation of EMS and other test systems easier.
  • Auxiliary modules such as RF attenuators can be easily combined with relay modules for advanced applications.
  • Module kit for versatile off-the-shelf customization

Overview of modules with RF coaxial relays
Open Lightbox

Overview of modules with RF coaxial relays

Expandable system configurations

Easy system integration and virtually unlimited expandability

All R&S®OSP models can be combined via Ethernet in a local, corporate or global network with a primary/secondary configuration. Existing R&S®OSP systems can be expanded to meet future requirements.
The compact R&S®OSP‑B200S2 satellite box can be used for remote operation as an alternative to networking multiple R&S®OSP units. The satellite box moves RF switching and controlling closer to the DUT or antennas,. reducing the number of long RF cables required, improving RF performance of the setup and saving costs.

Possible OSP unit and satellite box combinations
Open Lightbox

Possible OSP unit and satellite box combinations

Intuitive operation

Easy manual operation and remote control using web interface

R&S®OSP models come with a built-in web interface for local operation or remote control from a PC or laptop with browser. When control is browser based, the displayed content resolution is automatically adjusted to the monitor screen size.
All R&S®OSP models can be controlled with a keyboard and mouse and an external HDMITM monitor.

Web GUI for switching and path definition
Open Lightbox

Web GUI for switching and path definition

Path control

Efficient manual operation or programming

  • Relay switching states are combined to define paths, simplifying control and programming for complex wiring configurations.
  • Being able to copy and paste the syntax of manually defined paths into SCPI commands makes for very efficient SCPI programming.

Path definition example for relays in different modules
Open Lightbox

Path definition example for relays in different modules

Trigger function

Faster Switching

External triggers control switching processes more precisely and make them up to 1000 times faster when solid-state relays are used. Key trigger function features

  • Very fast OSP module switching with solid state relays (SSR), up to 1000 times faster than LAN
  • Hardware controlled switching of all switching elements by
    - external measurement devices
    - external hardware of a measurement setup
  • Precise and reproducible switching in line with the trigger signal
  • Four different trigger types: single, toggle, sequenced and addressed
  • Trigger can be configured via SCPI and touchscreen
  • Manual trigger for debugging without ext. trigger signal
  • The GUI displays the minimal trigger interval/maximum trigger frequency for the configuration

R&S®OSP unit with trigger interfaces on the front side.
Open Lightbox

R&S®OSP unit with trigger interfaces on the front side.

The trigger menu shows the minimum trigger interval possible for the given path configuration

Available options

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.