20 Results
Versatile Software Tool for Rohde & Schwarz Instruments
RSCommander is a versatile software tool for a wide range of Rohde & Schwarz spectrum-, network analyzers, signal generators and oscilloscopes. It allows for automatic instrument discovery, making screenshots, reading traces, file transfer and simple script creation.
24-Dec-2017 | AN-No. 1MA074
Noise Power Ratio Signal Generation and Measurement
Noise Power Ratio (NPR) is an add-on tool for WinIQSIM™ to generate noise power ratio stimulus signals and measure the resulting noise power ratio of a device under test (DUT) using Rohde & Schwarz instruments via LAN or GPIB bus.
06-Nov-2015 | AN-No. 1MA29
IQWizard is a tool for loading IQ signal files in various formats and measuring IQ signals with a FSx spectrum analyzer or ESx Receiver. The obtained IQ data in memory can be stored in various formats or be transmitted to an R&S® vector signal generator with WinIQSIM™ or WinIQSIM2™.
26-Apr-2013 | AN-No. 1MA028
The use of Rohde & Schwarz device drivers under VEE software is not complicated. However, a number of factors are involved, the errors that occur are often difficult to diagnose. This application provides easy and detailed support for installation and troubleshooting using National Instruments or Agilent GPIB boards.
20-Dec-2012 | AN-No. 1MA035
An FSE (or FSIQ) Spectrum Analyser equipped with the Vector Analysis option (FSE-B7) can measure a wide range of error types (EVM, Magnitude Error, Phase Error…) on continous signal. This Application Note describes how to measure these errors on a single burst between symbols.
22-Jan-2011 | AN-No. 1ES48
FSxRecordPlay is a program for recording the trace data in frequency and time domain from Rohde & Schwarz spectrum analyzers and measurement receivers via IEEE bus, LAN/Internet or internal remote control connection. The stream waveform data can be played back and analyzed directly in this software with variable speed.
20-May-2010 | AN-No. RAC-0605-0004
Application note 1MA25 has been replaced by application note .
28-Aug-2009 | AN-No. 1MA25
Spectrum and network analyzers are capable of measuring large amounts of data that require complex mathematical processing; MATLAB is a powerful tool for such operations. This application note describes how instruments can be controlled directly from MATLAB scripts and how measurement data can be imported into MATLAB. Only 32-bit MATLAB is supported.
24-Sep-2007 | AN-No. 1EF46
With AMPTUNE amplifier nonlinearity can be measured with signals that are typical for the signals encountered by the amplifier in day-to-day use. The measurement can be checked by pre-distorting the control signal. Also, the results can be automatically stored for further processing with external programs.
26-Oct-2005 | AN-No. 1MA27
This application note describes the different memory types and locations that user information can be stored in a spectrum analyzer R&S® FSEA, R&S® FSEB, R&S® FSEM, R&S® FSEK or R&S® FSIQ, as well as the different ways in which it can be erased/cleared for security reasons.
20-Sep-2004 | AN-No. 1EF54
This Application Note describes measurements compliant with the cdma2000® base station standard described in 3GPP2 C.S0010 / TIA/EIA-97 / ARIB STD-T64-C.S0010.The primary focus is on solutions for generating and analyzing cdma2000® signals. The special characteristics that make the selected signal generators and signal analyzers eminently suitable for this purpose are detailed, and remote control programming is demonstrated by a free of charge program.
05-Sep-2003 | AN-No. 1MA61
Spectrum and network analyzers equipped with network interface cards can be integrated in Local Area Networks (LAN). This Application Note describes how to remote control these instruments over a LAN and use VXIpnp instrument drivers over a LAN.
25-Jun-2003 | AN-No. 1EF47
In digital wireless communication systems one or multiple users are assigned to a physical RF channel. With analog systems only one user per carrier is possible. Output spectrum of the transmitter has to be restricted to the assigned channel in order to avoid interference with the neighbor channels. With the switch over to digital modulation formats more user per channel are possible. They share one channel by using only part of the time for transmission (Time Division Multiplex Access, TDMA) or by coding the transmission by orthogonal sequences for distinction to other users (Code Division Multiples Access, CDMA). Beneath the restriction of modulation spectrum with TDMA systems also time behavior of the transmitted signal is critical. One reason is that in a multi-user situation only one user is allowed to transmit within his assigned time slots. Another reason is that by switching a carrier on and off spectrum of the transmitter splatters and causes additional interference in other RF channels.
17-Jan-2002 | AN-No. 1EF32
Adjacent Channel Power performance of power amplifiers used in digital TV systems has to be guaranteed over a wide frequency range, 54 to 890 MHz, which may lead to time consuming test procedures. The application software described here provides swept ACP analysis, using AMIQ and SMIQ for signal generation and FSP, FSU or FSE for signal analysis. ACP measurement is performed according to FCC Regulation 47CFR 73.622(h).
16-Oct-2001 | AN-No. 1MA43
This application note explains the measurements on 3GPP Base Station Transmitter signals according to TS 25.141, using the Signal Analyzer FSIQ with the Code Domain Power application firmware FSIQ-K72.
17-Aug-2001 | AN-No. 1EF44
This application note describes measurements compliant with the cdma2000® standard described in TIA/EIA-97-C and TIA/EIA-98-C. The primary focus is on solutions for generating and analyzing cdma2000® signals with equipment from Rohde & Schwarz. The special characteristics that make the signal generators and signal analyzers eminently suitable for this purpose are detailed.
27-Mar-2001 | AN-No. 1MA34
Power amplifiers in digital TDMA mobile phones are fed with current only during the active slot to save power. Using conventional measuring equipment, the noise figure, an important parameter in power amplifiers, can only be determined with the amplifier in continuous operation. However, continuous operation can lead to amplifier overload and produce distorted results. Now there is a convenient way of determining the noise figure of amplifiers with pulsed power supply: using a Spectrum Analyzer (FSP or FSE or FSIQ or ESI), Noise Measurement Software FS-K3 and a function or pulse generator.
19-Dec-2000 | AN-No. 1MA32
The combination of an SMIQ Signal Generator and an FSE / FSIQ Analyzer enables the most important transmitter and receiver tests on ICO user terminals in quality management and development. This application note presents a series of quick tests in unsynchronized, non-signalling mode. To facilitate integration of SMIQ and FSE / FSIQ into existing test systems, complex instrument settings are supplied as sets of IEC/IEEE-bus commands. Sample files with burst data for uplink and downlink signals allow the configuration, execution and optimization of the tests described, even without a DUT.
08-May-2000 | AN-No. 1MA23
MobiDemo is an application software for controlling a combination of Generator SMIQ and Analyzer FSE/ FSE-B7 or FSIQ. MobiDemo offers a convenient user interface to facilitate testing of components used in digital mobile radio systems, for instance amplifiers or filters. The software can handle the GSM, PHS, IRIDIUM, IS-95 and W-CDMA standards. The corresponding test signals can be activated on SMIQ with a few keystrokes and mouse clicks. FSE/FSIQ is set up in accordance with SMIQ and analyzes signals in the modulation analysis or adjacent-channel power measurement mode. The settings for SMIQ and FSE/FSIQ are transferred via the IEC/IEEE bus.
09-Jul-1999 | AN-No. 1MA11
An FSE Spectrum Analyser equipped with the Vector Signal Analysis option (FSE-B7) can measure oscillator settling time or transmitter attack and release times with high accuracy up to 40 GHz. No additional measurement equipment is needed.
12-Feb-1999 | AN-No. 1MA15