103 Results
This document provides the technical specifications of the R&S®ELEKTRA EMC test software.
The R&S®ELEKTRA EMC test software can be used to control complete EMC test systems to perform automated or interactive electromagnetic interference (EMI) and electromagnetic susceptibility (EMS) measurements on equipment under test (EUT) to verify compliance with relevant standards.
This Application Note describes how to set up the EMC test software R&S®ELEKTRA and the visual inspection softwareR&S®AdVISE for remote testing.
23-Jul-2020 | AN-No. 1S005
Models: R&S®ELEMI-E, R&S®ELEMI-EA, R&S®ELEMI-EAS, R&S®ELEMS-C, R&S®ELEMS-CS, R&S®ELEMS-R, R&S®ELEMS-RS, R&S®ELEMS-CRS
This application note describes the use of the Rohde & Schwarz Elektra time-domain measurement system for in-depth evaluation of the RF performance of EMC/EMC application nodes with real-time requirements.
27-Jul-2022 | AN-No. 1SL384
Using R&S®ELEKTRA Migration Tool
The R&S®ELEKTRA EMC test software is the successor of the R&S®EMC32 EMC measurement software. Like the R&S®EMC32 EMC measurement software, the R&S®ELEKTRA offers a solution that controls complete EMC systems and automates measurements on equipment under test (EUT) that is being tested for emissions (EMI) and immunity (EMS) compliance. It has more features and test types compared to R&S®EMC32.As both software platforms use different file formats, R&S®EMC32 users who upgrade their existing software to the R&S®ELEKTRA platform need to perform a file conversion before migrating their data to the R&S®ELEKTRA platform. This is done by using the R&S®ELEKTRA Migration Tool, which is installed automatically with each R&S®ELEKTRA installation.This Application Note describes how to use the R&S®ELEKTRA Migration Tool (version 4.4 onwards) for converting the backup data into the XML format that can be interpreted by the R&S®ELEKTRA software. It also provides recommended conversion steps (Chapter 5) and troubleshooting tips (Chapter 6). For instructions on migrating the data using R&S®ELEKTRA Migration Tool below version 4.4, refer to the R&S®ELEKTRA user manual. For better user experience, we recommend using the latest software version for migration.This Application Note does not describe the steps to backup data using the R&S®EMC32 or R&S®ES-SCAN software. For procedures on how to do so, refer to their respective manuals.
04-May-2023 | AN-No. 1SL396
How to configure generic devices in R&S®ELEKTRA
Configuration of generic drivers to implement third-party devices
04-May-2023 | AN-No. 1SL398
This application note shows how to configure the R&S®AdVISE visual inspection software to automate the immunity testing in line with EN 55020 and CISPR 35 on TV sets and monitors.
30-Jul-2020 | AN-No. 1S007
EMC test solutions on the cutting edge - White Paper
R&S®ELEMI-E Essential EMI Test Software - Product Brochure
05-Mar-2024
Rohde & Schwarz at EMV 2024: Outstanding T&M solutions from the market leader in EMCAt the EMV show 2024 in Cologne, Rohde & Schwarz showcases a comprehensive range of EMC test and measurement solutions – ranging from standalone instruments and software to application-specific systems. The company dedicates a large part of the booth to demonstrations that show EMI compliance testing, EMC test automation, EMS immunity test, EMI debugging and EMF. The Rohde & Schwarz solutions are on display from March 12 to 14, 2024 at the Cologne exhibition center, hall 11.1, booth 106.
Copy the entire database from old version of ELEKTRA to the latest version of ELEKTRA
ELEKTRA, restart license server
ELEKTRA, Limit Lines with gaps
ELEKTRA, pre-define scaling of the graphics
Use of ELEKTRA on a non-Test-PC.
Automatically park antenna at specific position using ELEKTRA
How to install multiple version of ELEKTRA.
How would all the transducers, limit lines form the ES-Scan be moved to the new installation of ELEKTRA.
ELEKTRA, Acceptance Analysis not working for a given Limit Line
I would also like to use a Switch Unit to switch between the antennas. How can I configure swiched signal pathes with ELEKTRA?
ELEKTRA, export result tables to csv files, select decimal seperator
Does ELEKTRA software have possibility to use the Open TEM cell for Radiated Emission?
ELEKTRA Remote Control, Test Receiver does not show Limit Line and Transducer
Calibrating a clamp and creating a transducer table using the R&S ELEKTRA signal path calibration utility
I am going to migrate EMC32 system in ELEKTRA using the Migration Tool. It seems the Migration Tool has a problem reading the DeviceList.
I noticed that not all options of the Test Receiver are shown in ELEKTRA Device List. For example, option FSL-B7 is not displayed in Device List. Does that matter?
I am existing EMC32 customer. It is possible to migrate my EMC32 templates to ELEKTRA?
I have ELEKTRA dongle connected to my PC, but some of my devices from Device List are missing. Because of this I would like to simulate my Test, but the button "Simulate" is missing after Device Check.