R&S®RTB2000 oscilloscope

R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 oscilloscope
Open Lightbox
R&S®RTB2000 Oscilloscope, Front view R&S®RTB2000 Oscilloscope, Side view R&S®RTB2000 Oscilloscope, Hero view R&S®RTB2000 Oscilloscope, Back view R&S®RTB2000 Oscilloscope, Front view R&S®RTB2000 Oscilloscope, Side view R&S®RTB2000 Oscilloscope, Application Image

Key Facts

  • Bandwidth: 70 MHz to 300 MHz
  • Sample rate: up to 2.5 Gsample/s
  • Memory depth: up to 20 Msample
  • ADC resolution: 10 bit
  • Display: 10.1" capacitive touchscreen

More signal details with the power of 10

Power of ten (10-bit ADC, 10 Msample memory and 10.1" touchscreen) combined with smart operating concepts make the R&S®RTB2000 oscilloscopes the perfect tool for university laboratories, for troubleshooting embedded designs during development and for production and service departments.

  • Four times more vertical resolution than standard 8-bit ADCs.
  • Maintains fast sampling rates at all times
  • Largest display with highest resolution in its class

Caractéristiques & avantages

Signal analysis: quick results

See small signal details in the presence of large signals

The R&S®RTB2000 features a customized Rohde & Schwarz engineered 10-bit A/D converter that delivers a fourfold improvement compared to conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltages across the switching device must be determined during the on/off times within the same acquisition.

10-bit A/D converter
Open Lightbox

10-bit A/D converter

The Rohde & Schwarz designed 10-bit A/D converter ensures highest signal fidelity at highest resolution.

Capture more time at full bandwidth

10 Msample standard and 20 Msample interleaved

The R&S®RTB2000 offers a class-leading memory depth: 10 Msample per channel are available, even 20 Msample in interleaved mode. This is 10 times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates, e.g. when analyzing transients of switched-mode power supplies, and thus benefits from more detailed analysis results.

10 Msample standard memory
Open Lightbox

10 Msample standard memory

Capture and analyze pulsed and burst signals over a long period with up to 20 Msample standard acquisition memory.

Segmented memory

160 Msample with history function

The R&S®RTB-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. Thanks to the variable segment size, the 160 Msample memory is optimally utilized. In history mode, previous acquisitions to the maximum segmented memory depth of 160 Msample are available for further analysis.

160 Msample segmented memory
Open Lightbox

160 Msample segmented memory

Capture the longest time periods with class-leading 160 Msample memory.

Logic analysis with the MSO option

16 additional digital channels

The R&S®RTB-B1 option turns every R&S®RTB2000 into an intuitive-to-use MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and time-correlated to each other. For example, the delay between input and output of an A/D converter can conveniently be determined using the cursor measurements.

Four-bit DAC signal change.
Open Lightbox

Four-bit DAC signal change.

The R&S®RTB2000 captures and analyzes analog and digital signals synchronously and in time-correlated to each other.

Waveform and pattern generator

Generate analog and digital stimuli

The R&S®RTB-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns for e.g. I2C, SPI, UART and CAN/LIN can be used.

Waveform and pattern generator
Open Lightbox

Waveform and pattern generator

In addition to common sine, square/pulse, ramp and noise waveforms, it outputs user-defined waveforms and 4-bit signal patterns.

Digital voltmeter

Measure and display electrical potential

The R&S®RTB2000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Measurement functions include DC, AC+DC (RMS) and AC (RMS) – included as standard.

Digital voltmeter
Open Lightbox

Digital voltmeter

The 3-digit voltmeter measures and displays the electrical potential difference between two points in an electric circuit.

Frequency analysis mode

Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTB2000 is activated at the push of a button and by simpling entering the center frequency and span. Thanks to the R&S®RTB2000 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128 kpoints. Other practical tools include cursor measurements and autoset in frequency domain.

Frequency analysis mode
Open Lightbox

Frequency analysis mode

The high-performance FFT functionality analyzes signals up to 128 kpoints.

Mask test mode

Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. By using statistical pass/fail evaluation, they assess quality and stability of a DUT. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S®RTB2000. This pulse output can be used to trigger actions in the measurement setup.

Mask test with result statistics
Open Lightbox

Mask test with result statistics

The pass/fail evaluation assesses the quality and stability of the DUT.

Ready for the teaching lab

In the teaching lab, the R&S®RTB2000 oscilloscope is the perfect choice to teach students how to measure with an oscilloscope. It has an easy-to-use concept combined with state-of-the-art technology – at an affordable price. The large 10.1" high-resolution screen shows every signal detail, and one instrument can be shared among several students. Reports can be efficiently created with the handy and flexible screen annotation tool.

Ready for the teaching lab
Open Lightbox

Ready for the teaching lab

Perfect instruments for everyday use at universities and colleges thanks to diverse functionality, rugged design and small footprint.

Available models

Available models
Modèles
Bandwidth
Sample rate
Max. memory depth
Optional MSO
Commençant à

R&S®RTB-BNDL

Numéro de commande 1333.1005P98

Bandwidth
300 MHz
Sample rate
2,5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Commençant à
Prix sur demande
Specifications
Vertical system
Analog channels R&S®RTB2002; R&S®RTB2004 2; 4
Digital channels (opt.) 16
Bandwidth (-3 dB) R&S®RTB2002/2004 (with R&S®RTB-B2x1, R&S®RTB-B2x2 and R&S®RTB-B2x3 options) 70 MHz, 100 MHz, 200 MHz, 300 MHz
Rise time R&S®RTB2002/2004 (with R&S®RTB-B2x1, R&S®RTB-B2x2 and R&S®RTB-B2x3 options) 5 ns, 3.5 ns, 1.75 ns, 1.15 ns
Input impedance 1 MΩ ± 2% with 9 pF ± 2 pF (meas.)
Input sensitivity max. bandwidth in all ranges 1 mV/div to 5 V/div
ADC resolution 10 bit, up to 16 bit with high resolution decimation
DC gain accuracy offset and position = 0, maximum operating temperature change of ±5°C after self-alignment input sensitivity > 5 mV/div: ± 1.5% of full scale
input sensitivity ≤ 5 mV/div: ± 2% of full scale
Acquisition system
Realtime sampling rate 1.25 Gsample/s; 2.5 Gsample/s, interleaved
Acquisition memory standard; with R&S®RTB-K15 option 10 Msample; 20 Msample, interleaved;
160 Msample segmented memory
Max. acquisition rate 50 000 waveforms/s
(300 000 in fast segmented memory mode)
Horizontal system
Timebase range selectable between 1 ns/div and 500 s/div
Accuracy (after delivery/calibration) ±2.5 ppm
Channel-to-channel skew max. 800 ps (meas.)
Channel deskew ±500 ns
Trigger system
Standard Trigger types edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus
Optional Trigger types I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN
Trigger sensitivity with DC, AC, LF reject input sensitivity > 5 mV/div: < 0.8 div (meas.);
2 mV/div ≤ input sensitivity < 5 mV/div: < 1.5 div (meas.);
input sensitivity < 2 mV/div: < 2 div (meas.)
with HF reject all input sensitivities < 1 div (meas.)
Analysis and measurement functions
Automatic measurements  32
Cursor measurements 4
Waveform mathematics  5 equations math on math (addition, substraction, multiplication, division, square, square root, abs. value, reciprocal, inverse, common log,, natural log., derivative, integral, low pass, track unipolar + bipolar on period, frequency, pulse width, duty cycle) 
Mask testing
Mask definition elementary (tolerance mask around the signal)
History and segmented memory
Number of segments up to 13 107
Protocol trigger and decode
Supported protocols I2C, SPI, UART/RS-232/ RS-422/RS-485, CAN, LIN
Waveform generator
Resolution 14-bit
Sample rate 250 Msample/s
Amplitude high-Z; 50 Ω 20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp)
DC offset high-Z; 50 Ω ±2.5 V; ±1.25 V
Arbitrary sampling rate; memory depth max. 10 Msample/s; 16k point
Logic analyzer (MSO) functionality
Digital input channels 16
MSO Memory depth 10 Msample for every channel
MSO Bandwidth 300 MHz (meas.)
MSO sampling rate 1.25 Gsample/s
MSO input impedance 100 kΩ ± 2 % || ~4 pF (meas.) at probe tips
Parallel buses up to 2
General data
Dimensions W × H × D 390 mm × 220 mm × 152 mm
(15.4 in × 8.66 in × 5.98 in)
Weight 2.5 kg (5.5 lb)
Display 10.1" WXGA TFT color display (1280 × 800 pixel)
Interfaces USB host with MTP, USB device, LAN, powerful web server for remote display and operation
Operating system Embedded

Available options

General
Produit
Désignation

Numéro de commande 1333.1105.02

Désignation

Mixed signal upgrade for non-MSO models, 300 MHz

Turns the R&S®RTB2000 oscilloscope into fast, precise and easy-to-use mixed signal oscilloscopes (MSO).

R&S®RTB-B6

Numéro de commande 1333.1111.02

Désignation

Arbitrary waveform generator

Adds an 25 MHz signal generator and a 4-bit pattern generator to your R&S®RTB2000 oscilloscope

Serial triggering and decoding
Produit
Désignation

Numéro de commande 1333.1011.02

Désignation

I²C/SPI serial triggering and decoding

Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses

Numéro de commande 1333.1028.02

Désignation

UART/RS-232/RS-422/RS-485 serial triggering

Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses

Numéro de commande 1333.1034.02

Désignation

CAN/LIN serial triggering and decoding

Triggering and decoding of CAN and LIN interfaces

General analysis
Produit
Désignation

Numéro de commande 1333.1040.02

Désignation

History and segmented memory

History and 160 Msample segmented memory

Numéro de commande 1335.8007.02

Désignation

Frequency Response Analysis (Bode plot)

The R&S®RTB-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio.

General accessories
Produit
Désignation
R&S®RTB-Z1

Numéro de commande 1333.1728.02

Désignation

Front cover

Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000

R&S®RTB-Z4

Numéro de commande 1335.9290.02

Désignation

Transit case with wheels for R&S®RTB

R&S®RTB-Z3

Numéro de commande 1333.1734.02

Désignation

Soft bag

Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories

R&S®ZZA-RTB2K

Numéro de commande 1333.1711.02

Désignation

19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU

Numéro de commande 1335.7875.02

Désignation

Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes

Passive probes
Produit
Désignation

Numéro de commande 1803.1001.02

Désignation

Passive probe, 300 MHz, 10:1

Numéro de commande 1333.2401.02

Désignation

Passive probe, 500 MHz, 10:1

Numéro de commande 1409.7550.00

Désignation

Passive probe, 500 MHz, 10:1

Numéro de commande 1333.1370.02

Désignation

Passive probe, 38 MHz, 1:1

High voltage probes
Produit
Désignation

Numéro de commande 1333.0873.02

Désignation

250 MHz passive high voltage probe

Numéro de commande 1409.7720.02

Désignation

400 MHz passive high voltage probe

Numéro de commande 1409.7737.02

Désignation

400 MHz passive high voltage probe

Logic probes
Produit
Désignation
R&S®RT-ZL03

Numéro de commande 1333.0715.02

Désignation

300 MHz logic probe, 8 channels

Probe accessories
Produit
Désignation

Numéro de commande 1333.0850.02

Désignation

AC/DC 20 kHz current probe

Numéro de commande 1333.0844.02

Désignation

100 kHz current probe

Numéro de commande 1409.7750K02

Désignation

10 MHZ current probe

Numéro de commande 1409.7766K02

Désignation

100 MHZ current probe

Numéro de commande 1409.7772K02

Désignation

120 MHz current probe

Numéro de commande 1801.4932.02

Désignation

120 MHz current probe

Numéro de commande 1409.7789.02

Désignation

Power supply for probes

Power supply for R&S®RT-ZC10/20/30/31 probes, +/-12V DC, +/-2.5A

Application bundles
Produit
Désignation
R&S®RTB-PK1

Numéro de commande 1333.1092.02

Désignation

Application bundle (R&S®RTB-K1, -K2, -K3, -K15, -K36 and -B6)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTB-K1), UART/RS-232/RS-422/RS-485 (R&S®RTB-K2) and CAN/LIN (R&S®RTB-K3), history and segmented memory (R&S®RTB-K15), frequency response analysis (R&S®RTB-K36), arbitrary generator (R&S®RTB-B6) for R&S®RTB2000 models

R&S®RTB2000 – Centre de médias

RTB2000 - 10 bit ADC
CAN sur 10 bits pour visualiser les petits détails des signaux en présence de larges signaux
RTB2000 - 10 Msample memory
Mémoire de 10 Méchantillons pour capturer plus de temps à pleine bande passante
RTB2000 - high-resolution capacitive touchscreen
Écran tactile capacitif haute résolution de 10,1" avec prise en charge des mouvements

Ce qui pourrait également vous intéresser

Rocket Science AG - Case Study

Active noise control in daily operation – Rocket Science uses state-of-the-art active noise control and a Rohde & Schwarz oscilloscope to combat irritating noise.

Download now

Fondamentaux des oscilloscopes et des sondes

En savoir plus à propos du fonctionnement de base d'un oscilloscope, des sondes, ainsi que des diverses applications associées aux oscilloscopes, qui vous aident à optimiser vos résultats de mesure.

Plus d'information

Promotion sur les oscilloscopes

Choisissez la bonne promotion R&S en fonction de vos besoins individuels et faîtes d'économies

Plus d'information

Centre de webinaires dédié aux oscilloscopes pour les applications d'électronique de puissance et de conceptions numériques

Plus d'information

Jusqu'à 50% d'économies supplémentaires sur les oscilloscopes Rohde & Schwarz pour les clients de l'enseignement

Plus d'information

Les 10 ans de Rohde & Schwarz en termes d'innovation dans le domaine des oscilloscopes

Plus d'information

Demander des informations

Vous avez des questions ou besoin d'informations supplémentaires ? Remplissez simplement ce formulaire et nous vous recontacterons rapidement.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.